메뉴 건너뛰기




Volumn 37, Issue 3, 1990, Pages 164-175

Flow Velocity Profile via Time-Domain Correlation: Error Analysis and Computer Simulation

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; MEASUREMENT ERRORS; NOISE, SPURIOUS SIGNAL--WHITE NOISE; SIGNAL PROCESSING; VELOCIMETERS--ULTRASONIC DOPPLER;

EID: 0025432134     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/58.55306     Document Type: Article
Times cited : (177)

References (25)
  • 1
    • 0025405536 scopus 로고
    • Pulsed Dopplcr accuracy assessment due to frequency-dependent attenuation and Rayleigh scattering error sources
    • Mar.
    • P. M. Embrcc and W. D. O’Brien, Jr., “Pulsed Dopplcr accuracy assessment due to frequency-dependent attenuation and Rayleigh scattering error sources.” IEEE Trans. Biomed. Eng., vol. 37, no. 3, pp. 322–326. Mar. 1990.
    • (1990) IEEE Trans. Biomed. Eng. , vol.37 , Issue.3 , pp. 322-326
    • Embrcc, P.M.1    O’Brien, W.D.2
  • 2
    • 0022260296 scopus 로고
    • Measurement of blood flow by ultrasound: Accuracy and sources of error
    • R. W. Gill, “Measurement of blood flow by ultrasound: Accuracy and sources of error.” Ultrasound Med. Biol., vol. 11, pp. 625–641, 1985.
    • (1985) Ultrasound Med. Biol. , vol.11 , pp. 625-641
    • Gill, R.W.1
  • 3
    • 0016413538 scopus 로고
    • Blood flow measurements using ultrasonic random signal Doppler system
    • Jan.
    • C. P. Jethwa. M. Kaveh. G. R. Cooper, and F. Saggio, “Blood flow measurements using ultrasonic random signal Doppler system.” IEEE Trans. Sonies Ultrason., vol. SU-22, pp. 1–11. Jan. 1975.
    • (1975) IEEE Trans. Sonies Ultrason. , vol.SU-22 , pp. 1-11
    • Jethwa, C.P.1    Kaveh, M.2    Cooper, G.R.3    Saggio, F.4
  • 4
    • 0019728527 scopus 로고
    • Instantaneous frequency, mean frequency, and variance of mean frequency estimator for ultrasonic blood velocity Doppler signals
    • B. Angelsen. “Instantaneous frequency, mean frequency, and variance of mean frequency estimator for ultrasonic blood velocity Doppler signals,” IEEE Trans. Biomed. Eng., vol. BME-28, pp. 733–741. 1981.
    • (1981) IEEE Trans. Biomed. Eng. , vol.BME-28 , pp. 733-741
    • Angelsen, B.1
  • 5
    • 0020971615 scopus 로고
    • Discrete time estimation of the mean Doppler frequency in ultrasonic blood velocity measurements
    • B. Angelsen and K. Kristoffersen, “Discrete time estimation of the mean Doppler frequency in ultrasonic blood velocity measurements.” IEEE Trans. Biomed. Engr., vol. BME-30, pp. 207–214, 1983.
    • (1983) IEEE Trans. Biomed. Engr. , vol.BME-30 , pp. 207-214
    • Angelsen, B.1    Kristoffersen, K.2
  • 6
    • 0014797429 scopus 로고
    • Pulsed ultrasonic Doppler blood flow sensing
    • D. W. Baker. “Pulsed ultrasonic Doppler blood flow sensing,” IEEE Trans. Sanies Ultrason., vol. SU-17, pp. 170–185, 1970.
    • (1970) IEEE Trans. Sanies Ultrason. , vol.SU-17 , pp. 170-185
    • Baker, D.W.1
  • 7
    • 0016699479 scopus 로고
    • A novel pulsed directional Doppler velocime-tcr. the phase-detection profilometer.
    • P. A. Grandchamp, “A novel pulsed directional Doppler velocime-tcr. the phase-detection profilometer.” in Proe. 2nd Eur. Cong. Ultrasound in Med., pp. 137–143, 1975.
    • (1975) Proe. 2nd Eur. Cong. Ultrasound in Med. , pp. 137-143
    • Grandchamp, P.A.1
  • 8
    • 0016805435 scopus 로고
    • Application of the phase detection principle in a transcutaneous velocity profile meter.
    • M. Brandestini, Application of the phase detection principle in a transcutaneous velocity profile meter.” in Proe. 2nd Eur. Cong. Ultrasound in Med., pp. 144–152, 1975.
    • (1975) Proe. 2nd Eur. Cong. Ultrasound in Med. , pp. 144-152
    • Brandestini, M.1
  • 9
    • 0017905078 scopus 로고
    • Topflow—A digital full-range Doppler velocity meter.
    • —, “Topflow—A digital full-range Doppler velocity meter.” IEEE Trans. Sonies Ultrason., vol. SU-25, pp. 287–293, 1978.
    • (1978) IEEE Trans. Sonies Ultrason. , vol.SU-25 , pp. 287-293
  • 12
    • 84939739865 scopus 로고
    • Real-time two-dimensional blood flow imaging using an autocorrelation technique
    • C. Kasai, K. Namekawa. A. Koyano, and R. Omoto, “Real-time two-dimensional blood flow imaging using an autocorrelation technique,” IEEE Trans. Sonies Ultrason., vol. SU-32, pp. 458–464, 1985.
    • (1985) IEEE Trans. Sonies Ultrason. , vol.SU-32 , pp. 458-464
    • Kasai, C.1    Namekawa, K.2    Koyano, A.3    Omoto, R.4
  • 14
    • 0025434403 scopus 로고
    • Volumetric blood flow via time domain correlation: Experimental verification
    • May
    • P. M. Embree and W. D. O’Brien, Jr., “Volumetric blood flow via time domain correlation: Experimental verification,” IEEE Trans. Ultrason. Ferroelec. Erea. Contr., vol. 37. no. 3, pp. 176–189. May 1990.
    • (1990) IEEE Trans. Ultrason. Ferroelec. Erea. Contr. , vol.37 , Issue.3 , pp. 176-189
    • Embree, P.M.1    O’Brien, W.D.2
  • 15
    • 0017017056 scopus 로고
    • Blood flow measurement by ultrasound correlation techniques
    • Nov.
    • D. Dotti, E. Gatti, V. Svelto, A. Uggc. and P. Vidali, “Blood flow measurement by ultrasound correlation techniques,” Energia Nueleare, vol. 23, pp. 571–575, Nov. 1976.
    • (1976) Energia Nueleare , vol.23 , pp. 571-575
    • Dotti, D.1    Gatti, E.2    Svelto, V.3    Uggc, A.4    Vidali, P.5
  • 17
    • 0019987617 scopus 로고
    • In vivo recording of blood velocity profiles and studies in vitro of profile alterations induced by known stenoses
    • June
    • M. Bassini, E. Gatti. T. Longo, G. Martinis, P. Pignoli, and P. Pizzolati, “In vivo recording of blood velocity profiles and studies in vitro of profile alterations induced by known stenoses,” Texas Heart Inst. J., vol. 9, pp. 185–194, June 1982.
    • (1982) Texas Heart Inst. J. , vol.9 , pp. 185-194
    • Bassini, M.1    Gatti, E.2    Longo, T.3    Martinis, G.4    Pignoli, P.5    Pizzolati, P.6
  • 18
    • 0022692830 scopus 로고
    • Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation.
    • O. Bonnefous and P. Pesque. “Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation.” Ultrason. Imaging, vol. 8, pp. 75–85, 1986.
    • (1986) Ultrason. Imaging , vol.8 , pp. 75-85
    • Bonnefous, O.1    Pesque, P.2
  • 20
    • 0018910679 scopus 로고
    • A theoretical study of the scattering from blood
    • B. Angelsen. “A theoretical study of the scattering from blood.” IEEE Trans. Biomed. Eng., vol. BME-27, pp. 61–67.1980.
    • (1980) IEEE Trans. Biomed. Eng. , vol.BME-27 , pp. 61-67
    • Angelsen, B.1
  • 21
    • 84872038496 scopus 로고
    • The accurate ultrasonic measurement of the volume How ot blood by time domain correlation
    • Ph.D. Thesis. Dept. Elcc. Eng., University of Illinois. Urbana. IL
    • P. M. Embree. “The accurate ultrasonic measurement of the volume How ot blood by time domain correlation.” Ph.D. Thesis. Dept. Elcc. Eng., University of Illinois. Urbana. IL, 1986.
    • (1986)
    • Embree, P.M.1
  • 22
    • 0003504044 scopus 로고
    • A pulsed ultrasonic flowmeter employing time domain methods
    • Ph.D. Thesis in Dept. Elec. Eng., University of Illinois. Urbana. IL.
    • S. G. Foster. “A pulsed ultrasonic flowmeter employing time domain methods,” Ph.D. Thesis in Dept. Elec. Eng., University of Illinois. Urbana. IL. 1984.
    • (1984)
    • Foster, S.G.1
  • 23
    • 0019583672 scopus 로고
    • Analysis of discrete implementation of generalized cross correlator
    • R. E. Boucher and J. C. Hassab. “Analysis of discrete implementation of generalized cross correlator.” IEEE Trans. Acoust., Speech Signal Processing, vol. ASSP-29, pp. 609–611. 1981.
    • (1981) IEEE Trans. Acoust., Speech Signal Processing , vol.ASSP-29 , pp. 609-611
    • Boucher, R.E.1    Hassab, J.C.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.