메뉴 건너뛰기




Volumn 8, Issue 17, 1998, Pages 2369-2374

Solid-phase synthesis of a library of piperazinediones and diazepinediones via Kaiser oxime resin

Author keywords

[No Author keywords available]

Indexed keywords

DIAZEPINE DERIVATIVE; DIPEPTIDE; OXIME; PEPTIDE LIBRARY; PIPERAZINEDIONE; RESIN;

EID: 0032497430     PISSN: 0960894X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0960-894X(98)00428-4     Document Type: Article
Times cited : (59)

References (19)
  • 4
    • 0028833961 scopus 로고
    • Solid-phase mix-and-split synthesis on Wang resin, post-cleavage cyclization in toluene, 110 °C
    • 4. Gordon, D. W.; Steele, J. Bioorg. Med. Chem. Lett. 1995, 5, 47. (Solid-phase mix-and-split synthesis on Wang resin, post-cleavage cyclization in toluene, 110 °C.)
    • (1995) Bioorg. Med. Chem. Lett. , vol.5 , pp. 47
    • Gordon, D.W.1    Steele, J.2
  • 9
  • 10
    • 0031000559 scopus 로고    scopus 로고
    • Solid-phase synthesis on Tentagel-S OH or PAM resin, simultaneous cyclization/cleavage, 1/1 toluene/EtOH with 1% AcOH or 4% Et3N, 20 °C
    • 10. Szardenings, A. K.; Burkoth, T. S.; Lu, H. H.; Tien, D. W.; Campbell, D. A. Tetrahedron 1997, 19, 6573. (Solid-phase synthesis on Tentagel-S OH or PAM resin, simultaneous cyclization/cleavage, 1/1 toluene/EtOH with 1% AcOH or 4% Et3N, 20 °C.)
    • (1997) Tetrahedron , vol.19 , pp. 6573
    • Szardenings, A.K.1    Burkoth, T.S.2    Lu, H.H.3    Tien, D.W.4    Campbell, D.A.5
  • 12
    • 0010409115 scopus 로고    scopus 로고
    • note
    • 12. Advanced ChemTech, 5609 Fern Valley Road, Louisville, KY 40228, U.S.A.
  • 13
    • 0010330307 scopus 로고    scopus 로고
    • note
    • 2), p-nitro-phenylalanine; 2-Abz, 2-aminobenzoic acid.
  • 14
    • 0030202425 scopus 로고    scopus 로고
    • note
    • 14. HPLC/UV/ELSD analyses employed Perkin-Elmer Pecosphere 3X3C C-18 reverse-phase cartridge columns (0.46 × 3.3 cm), at 3.0 mL/min, with an elution gradient of 0-70% aqueous acetonitrile (containing 0.1% TFA) over 7 min, then 70-100% over 0.5 min, then 100% for 2.5 min, with a 5-min equilibration period; UV detection was at 200 nm, and a Sedere Sedex Model 55 was used for evaporative light-scattering detection (ELSD). In general, the purity based on UV detection (200 nm) was somewhat less than that based on ELSD; however, ELSD is established to be a more "universal" detector, giving near-equivalent response to a variety of compounds (Kibbey, C. E. Mol. Diversity 1995, 1, 247). A Finnigan LCQ was used for LC/MS analyses.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.