메뉴 건너뛰기




Volumn 98, Issue 22, 1998, Pages 2487-2493

Optimal small-capacitor biphasic waveform for external defibrillation influence of phase-1 tilt and phase-2 voltage

Author keywords

Death, sudden; Defibrillation; Ventricles

Indexed keywords

ARTICLE; CAPACITANCE BLOOD VESSEL; DEFIBRILLATION; DIAGNOSTIC VALUE; ELECTRIC POTENTIAL; PREDICTION; PRIORITY JOURNAL; STATISTICAL ANALYSIS; SUDDEN DEATH;

EID: 0032403098     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.98.22.2487     Document Type: Article
Times cited : (20)

References (23)
  • 1
    • 0028263225 scopus 로고
    • Mechanisms of electrical defibrillation: Impact of new experimental defibrillator waveforms
    • Blanchard SM, Ideker RE. Mechanisms of electrical defibrillation: impact of new experimental defibrillator waveforms. Am Heart J. 1994;127: 970-977.
    • (1994) Am Heart J , vol.127 , pp. 970-977
    • Blanchard, S.M.1    Ideker, R.E.2
  • 4
    • 0029083307 scopus 로고
    • Transthoracic defibrillation of swine with monophasic and biphasic waveforms
    • Gliner BE, Lyster TE, Dillion SM, Bardy GH. Transthoracic defibrillation of swine with monophasic and biphasic waveforms. Circulation. 1995;92:1634-1643.
    • (1995) Circulation , vol.92 , pp. 1634-1643
    • Gliner, B.E.1    Lyster, T.E.2    Dillion, S.M.3    Bardy, G.H.4
  • 6
    • 0028034988 scopus 로고
    • A minimal model of the single capacitor biphasic defibrillation waveform
    • Kroll MW. A minimal model of the single capacitor biphasic defibrillation waveform. Pacing Clin Electrophysiol. 1994;17:1782-1792.
    • (1994) Pacing Clin Electrophysiol , vol.17 , pp. 1782-1792
    • Kroll, M.W.1
  • 7
    • 0029828038 scopus 로고    scopus 로고
    • Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms
    • Swerdlow CD, Fan W, Brewer JE. Charge-burping theory correctly predicts optimal ratios of phase duration for biphasic defibrillation waveforms. Circulation. 1996;94:2278-2284.
    • (1996) Circulation , vol.94 , pp. 2278-2284
    • Swerdlow, C.D.1    Fan, W.2    Brewer, J.E.3
  • 8
    • 0027243277 scopus 로고
    • A minimal model of the monophasic defibrillation pulse
    • Kroll MW. A minimal model of the monophasic defibrillation pulse. Pacing Clin Electrophysiol. 1993;16:769-777.
    • (1993) Pacing Clin Electrophysiol , vol.16 , pp. 769-777
    • Kroll, M.W.1
  • 9
    • 0028926798 scopus 로고
    • Optimal truncation of defibrillation pulses
    • Irnich W. Optimal truncation of defibrillation pulses. Pacing Clin Electrophysiol. 1995;18:673-688.
    • (1995) Pacing Clin Electrophysiol , vol.18 , pp. 673-688
    • Irnich, W.1
  • 11
    • 0345560427 scopus 로고    scopus 로고
    • The external biphasic waveform with changing capacitor at phase reversal reduced defibrillation energy
    • Abstract
    • Yamanouchi Y, Brewer JE, Hills DG, Donohoo AM, Steinkogler GL, Tchou PJ. The external biphasic waveform with changing capacitor at phase reversal reduced defibrillation energy. Circulation. 1997;96(suppl I):I-530. Abstract.
    • (1997) Circulation , vol.96 , Issue.1 SUPPL.
    • Yamanouchi, Y.1    Brewer, J.E.2    Hills, D.G.3    Donohoo, A.M.4    Steinkogler, G.L.5    Tchou, P.J.6
  • 14
    • 0030831099 scopus 로고    scopus 로고
    • Iridium oxide-coated defibrillation electrode: Reduced shock polarization and improved defibrillation efficacy
    • Niebauer MJ, Wilkoff BL, Yamanouchi Y, Mazgalev T, Mowrey KA, Tchou PS. Iridium oxide-coated defibrillation electrode: reduced shock polarization and improved defibrillation efficacy. Circulation. 1997;96:3732-3736.
    • (1997) Circulation , vol.96 , pp. 3732-3736
    • Niebauer, M.J.1    Wilkoff, B.L.2    Yamanouchi, Y.3    Mazgalev, T.4    Mowrey, K.A.5    Tchou, P.S.6
  • 15
    • 0031457129 scopus 로고    scopus 로고
    • An additional lead improves defibrillation efficacy with an abdominal "hot can" electrode system
    • Yamanouchi Y, Mowrey KA, Niebauer MJ, Tchou PJ, Wilkoff BL. An additional lead improves defibrillation efficacy with an abdominal "hot can" electrode system. Circulation. 1997;96:4400-4407.
    • (1997) Circulation , vol.96 , pp. 4400-4407
    • Yamanouchi, Y.1    Mowrey, K.A.2    Niebauer, M.J.3    Tchou, P.J.4    Wilkoff, B.L.5
  • 16
    • 0031418558 scopus 로고    scopus 로고
    • Direct comparison defibrillation efficacy with a single bipolar lead system and an unipolar "hot can" electrode system
    • Yamanouchi Y, Mowrey KA, Niebauer MJ, Tchou PJ, Wilkoff BL. Direct comparison defibrillation efficacy with a single bipolar lead system and an unipolar "hot can" electrode system. Eur J Cardiac Pac Electrophysiol. 1997;7:82-88.
    • (1997) Eur J Cardiac Pac Electrophysiol , vol.7 , pp. 82-88
    • Yamanouchi, Y.1    Mowrey, K.A.2    Niebauer, M.J.3    Tchou, P.J.4    Wilkoff, B.L.5
  • 19
    • 0010587276 scopus 로고
    • A priori nonorthogonal contrasts
    • Kirk RE, ed. Belmont, Calif: Brooks/Cole Publishing Co
    • Kirk RE. A priori nonorthogonal contrasts. In: Kirk RE, ed. Experimental Design: Procedures for the Behavioral Sciences. Belmont, Calif: Brooks/Cole Publishing Co; 1982:106-110.
    • (1982) Experimental Design: Procedures for the Behavioral Sciences , pp. 106-110
    • Kirk, R.E.1
  • 20
    • 0024401732 scopus 로고
    • Transthoracic defibrillation threshold of sine and trapezoidal waveforms in defibrillation
    • Wilson CM, Bailey A, Allen JD, Anderson J, Adgey AA. Transthoracic defibrillation threshold of sine and trapezoidal waveforms in defibrillation. J Electrocardiol. 1989;22:241-247.
    • (1989) J Electrocardiol , vol.22 , pp. 241-247
    • Wilson, C.M.1    Bailey, A.2    Allen, J.D.3    Anderson, J.4    Adgey, A.A.5
  • 21
    • 0027511198 scopus 로고
    • Transthoracic defibrillation: Effect of dual-pathway sequential pulse shocks and single-pathway biphasic pulse shocks in a canine model
    • Scott BD, Kallok MJ, Birkett C, Kieso RA, Kerber RE. Transthoracic defibrillation: effect of dual-pathway sequential pulse shocks and single-pathway biphasic pulse shocks in a canine model. Am Heart J. 1993;125: 99-109.
    • (1993) Am Heart J , vol.125 , pp. 99-109
    • Scott, B.D.1    Kallok, M.J.2    Birkett, C.3    Kieso, R.A.4    Kerber, R.E.5
  • 22
    • 0030897078 scopus 로고    scopus 로고
    • Defibrillation efficacy of commercially available biphasic impulses in humans: Importance of negative-phase peak voltage
    • Tomassoni G, Newby K, Deshpande S, Axtell K, Sra J, Akhtar M, Natale A. Defibrillation efficacy of commercially available biphasic impulses in humans: importance of negative-phase peak voltage. Circulation. 1997; 95:1822-1826.
    • (1997) Circulation , vol.95 , pp. 1822-1826
    • Tomassoni, G.1    Newby, K.2    Deshpande, S.3    Axtell, K.4    Sra, J.5    Akhtar, M.6    Natale, A.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.