Volumn 8, Issue 6, 1997, Pages 649-657

Optimized first phase tilt in 'parallel-series' biphasic waveform

Author keywords

Biphasic waveform; Defibrillation; First phase tilt; Parallel series switching; Small capacitor

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; CARDIOVERSION; DEFIBRILLATION; DISEASE CONTROL; ELECTRIC SHOCK; ELECTROCARDIOGRAM; HEART ARRHYTHMIA; HEART INJURY; INSTRUMENTATION; NONHUMAN; PRIORITY JOURNAL;

EID: 0030954321     PISSN: 10453873     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8167.1997.tb01828.x     Document Type: Article
Times cited : (11)

References (46)
  • 1
    • 0023206065 scopus 로고
    • Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms
    • Dixon EG, Tang AS, Wolf PD. et al: Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms. Circulation 1987;76:1176-1184.
    • (1987) Circulation , vol.76 , pp. 1176-1184
    • Dixon, E.G.1    Tang, A.S.2    Wolf, P.D.3
  • 2
    • 0024450327 scopus 로고
    • Comparison of the internal defibrillation thresholds for monophasic and double and single capacitor biphasic waveforms
    • Kavanagh KM, Tang AS, Rollins DL, et al: Comparison of the internal defibrillation thresholds for monophasic and double and single capacitor biphasic waveforms. J Am Coll Cardiol 1989;14:1343-1349.
    • (1989) J Am Coll Cardiol , vol.14 , pp. 1343-1349
    • Kavanagh, K.M.1    Tang, A.S.2    Rollins, D.L.3
  • 3
    • 0028263225 scopus 로고
    • Mechanisms of electrical defibrillation: Impact of new experimental defibrillator waveforms
    • Blanchard SM, Ideker RE: Mechanisms of electrical defibrillation: impact of new experimental defibrillator waveforms. Am Heart J 1994;127:970-977.
    • (1994) Am Heart J , vol.127 , pp. 970-977
    • Blanchard, S.M.1    Ideker, R.E.2
  • 4
    • 0028210702 scopus 로고
    • Mechanisms of defibrillation for monophasic and biphasic waveforms
    • Walcott GP, Walcott KT, Knisley SB, et al: Mechanisms of defibrillation for monophasic and biphasic waveforms. PACE 1994;17:478-498.
    • (1994) PACE , vol.17 , pp. 478-498
    • Walcott, G.P.1    Walcott, K.T.2    Knisley, S.B.3
  • 5
    • 0027171761 scopus 로고
    • A simplified, single-lead unipolar transvenous cardioversion-defibrillation system
    • Bardy GH, Johnson G, Poole JE. et al: A simplified, single-lead unipolar transvenous cardioversion-defibrillation system. Circulation 1993;88:543-547.
    • (1993) Circulation , vol.88 , pp. 543-547
    • Bardy, G.H.1    Johnson, G.2    Poole, J.E.3
  • 6
    • 0029005592 scopus 로고
    • Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system
    • Poole JE, Bardy GH, Kudenchuk PJ, et al: Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system. PACE 1995;18: 1369-1373.
    • (1995) PACE , vol.18 , pp. 1369-1373
    • Poole, J.E.1    Bardy, G.H.2    Kudenchuk, P.J.3
  • 7
    • 0030220823 scopus 로고    scopus 로고
    • Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator
    • Bardy GH, Yee R, Jung W: Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator. J Am Coll Cardiol 1996;28:400-410.
    • (1996) J Am Coll Cardiol , vol.28 , pp. 400-410
    • Bardy, G.H.1    Yee, R.2    Jung, W.3
  • 8
    • 0018373981 scopus 로고
    • Low-energy direct defibrillation of the human heart
    • Rubio PA, Farrell EM: Low-energy direct defibrillation of the human heart. Ann Thorac Surg 1979;27:32-33.
    • (1979) Ann Thorac Surg , vol.27 , pp. 32-33
    • Rubio, P.A.1    Farrell, E.M.2
  • 9
    • 0022713760 scopus 로고
    • Sequential pulse defibrillation for implantable defibrillators
    • Bourland JD, Tacker WA Jr, Wessale JL, et al: Sequential pulse defibrillation for implantable defibrillators. Med Instrument 1986;20:138-142.
    • (1986) Med Instrument , vol.20 , pp. 138-142
    • Bourland, J.D.1    Tacker Jr., W.A.2    Wessale, J.L.3
  • 10
    • 0027938254 scopus 로고
    • Relation between shock-related myocardial injury and defibrillation efficacy of monophasic and biphasic shocks in a canine model
    • Osswald S, Trouton TG, O'Nunain SS, et al: Relation between shock-related myocardial injury and defibrillation efficacy of monophasic and biphasic shocks in a canine model. Circulation 1994;90:2501-2509.
    • (1994) Circulation , vol.90 , pp. 2501-2509
    • Osswald, S.1    Trouton, T.G.2    O'Nunain, S.S.3
  • 11
    • 0021748988 scopus 로고
    • Unipolar electrode system for an implantable defibrillator: New experimental approaches
    • Fontaine G, Cansell A, Lechat P, et al: Unipolar electrode system for an implantable defibrillator: New experimental approaches. PACE 1984;7:1351-1356.
    • (1984) PACE , vol.7 , pp. 1351-1356
    • Fontaine, G.1    Cansell, A.2    Lechat, P.3
  • 12
    • 0022613312 scopus 로고
    • Electrocardiographic changes after cardioversion of ventricular arrhythmias
    • Eysmann SB, Marchlinski FE, Buxton AE, et al: Electrocardiographic changes after cardioversion of ventricular arrhythmias. Circulation 1986;73:73-81.
    • (1986) Circulation , vol.73 , pp. 73-81
    • Eysmann, S.B.1    Marchlinski, F.E.2    Buxton, A.E.3
  • 13
    • 0027199170 scopus 로고
    • Defibrillation shocks produce different effects on Purkinje fibers and ventricular muscle: Implications for successful defibrillation. refibrillation and postshock arrhythmia
    • Li HG, Jones DL, Yee R, et al: Defibrillation shocks produce different effects on Purkinje fibers and ventricular muscle: implications for successful defibrillation. refibrillation and postshock arrhythmia. J Am Coll Cardiol 1993;22:607-614.
    • (1993) J Am Coll Cardiol , vol.22 , pp. 607-614
    • Li, H.G.1    Jones, D.L.2    Yee, R.3
  • 16
    • 0342293181 scopus 로고
    • Effect of capacitance on defibrillation thresholds in dogs
    • DeGroot PJ, Norenberg MS, Mehra R: Effect of capacitance on defibrillation thresholds in dogs. (Abstract) Am Heart J 1994;128:640.
    • (1994) Am Heart J , vol.128 , pp. 640
    • DeGroot, P.J.1    Norenberg, M.S.2    Mehra, R.3
  • 17
    • 0028110428 scopus 로고
    • Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators
    • Swerdlow CD, Kass RM, Chen PS, et al: Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators. Circulation 1994;90:1840-1846.
    • (1994) Circulation , vol.90 , pp. 1840-1846
    • Swerdlow, C.D.1    Kass, R.M.2    Chen, P.S.3
  • 18
    • 0029101266 scopus 로고
    • Defibrillation thresholds are lower with smaller storage capacitors
    • Leonelli FM, Kroll MW, Brewer JE: Defibrillation thresholds are lower with smaller storage capacitors. PACE 1995;18:1661-1665.
    • (1995) PACE , vol.18 , pp. 1661-1665
    • Leonelli, F.M.1    Kroll, M.W.2    Brewer, J.E.3
  • 19
    • 0028850822 scopus 로고
    • A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF capacitance pulses using a unipolar defibrillation system
    • Bardy GH, Poole JE, Kudenchuk PJ, et al: A prospective randomized comparison in humans of biphasic waveform 60-μF and 120-μF capacitance pulses using a unipolar defibrillation system. Circulation 1995; 91:91-95.
    • (1995) Circulation , vol.91 , pp. 91-95
    • Bardy, G.H.1    Poole, J.E.2    Kudenchuk, P.J.3
  • 20
    • 0029619497 scopus 로고
    • A prospective randomized comparison in humans of 90-μF and 120-μF biphasic pulse defibrillation using a unipolar defibrillation system
    • Poole JE, Kudenchuk PJ, Dolack GL, et al: A prospective randomized comparison in humans of 90-μF and 120-μF biphasic pulse defibrillation using a unipolar defibrillation system. J Cardiovasc Electrophysiol 1995;6:1097-1100.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 1097-1100
    • Poole, J.E.1    Kudenchuk, P.J.2    Dolack, G.L.3
  • 21
    • 0028799556 scopus 로고
    • Large capacitor defibrillation waveform reduces peak voltages without increasing energies
    • Hahn SJ, Heil JE, Lang DJ: Large capacitor defibrillation waveform reduces peak voltages without increasing energies. PACE 1995;18:203-207.
    • (1995) PACE , vol.18 , pp. 203-207
    • Hahn, S.J.1    Heil, J.E.2    Lang, D.J.3
  • 22
    • 0029114201 scopus 로고
    • Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation
    • Walcott GP, Walker RG, Cates AW, et al: Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation. J Cardiovasc Electrophysiol 1995;6:737-750.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 737-750
    • Walcott, G.P.1    Walker, R.G.2    Cates, A.W.3
  • 23
    • 0030041075 scopus 로고    scopus 로고
    • Biphasic defibrillation using a single capacitor with large capacitance: Reduction of peak voltages and ICD device size
    • Block M, Hammel D, Bocker D, et al: Biphasic defibrillation using a single capacitor with large capacitance: Reduction of peak voltages and ICD device size. PACE 1996;19:207-214.
    • (1996) PACE , vol.19 , pp. 207-214
    • Block, M.1    Hammel, D.2    Bocker, D.3
  • 24
    • 0029790646 scopus 로고    scopus 로고
    • Short biphasic pulses from 90 microfarad capacitors lower defibrillation threshold
    • Swerdlow CD, Kass RM, Davie S, et al: Short biphasic pulses from 90 microfarad capacitors lower defibrillation threshold. PACE 1996;19:1053-1060.
    • (1996) PACE , vol.19 , pp. 1053-1060
    • Swerdlow, C.D.1    Kass, R.M.2    Davie, S.3
  • 25
    • 0027243277 scopus 로고
    • A minimal model of the monophasic defibrillation pulse
    • Kroll MW: A minimal model of the monophasic defibrillation pulse. PACE 1993;16:769-777.
    • (1993) PACE , vol.16 , pp. 769-777
    • Kroll, M.W.1
  • 26
    • 0030004265 scopus 로고    scopus 로고
    • Effect of changing capacitors between phases of a biphasic defibrillation shock
    • Walcott GP, Rollins DL, Smith WM, et al: Effect of changing capacitors between phases of a biphasic defibrillation shock. PACE 1996;19:945-954.
    • (1996) PACE , vol.19 , pp. 945-954
    • Walcott, G.P.1    Rollins, D.L.2    Smith, W.M.3
  • 27
    • 0029760653 scopus 로고    scopus 로고
    • Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching
    • Yamanouchi Y, Mowrey KA, Nadzam GR, et al: Large change in voltage at phase reversal improves biphasic defibrillation thresholds. Parallel-series mode switching. Circulation 1996;94:1768-1773.
    • (1996) Circulation , vol.94 , pp. 1768-1773
    • Yamanouchi, Y.1    Mowrey, K.A.2    Nadzam, G.R.3
  • 28
    • 0010587276 scopus 로고
    • A priori nonorthogonal contrasts
    • Kirk RE, ed. Brooks/Cole Publishing Company, Belmont, CA
    • Kirk RE: A priori nonorthogonal contrasts. In Kirk RE, ed: Experimental Design: Procedures for the Behavioral Sciences. Brooks/Cole Publishing Company, Belmont, CA, 1982, pp. 106-110.
    • (1982) Experimental Design: Procedures for the Behavioral Sciences , pp. 106-110
    • Kirk, R.E.1
  • 29
    • 8544284067 scopus 로고
    • Defibrillation theory and its clinical impact
    • Singer I, ed. Futura Publishing Company, Inc., Armonk, NY
    • Irnich W: Defibrillation theory and its clinical impact. In Singer I, ed: The Implantable Cardioverter-Defibrillator. Futura Publishing Company, Inc., Armonk, NY, 1994, pp. 135-152.
    • (1994) The Implantable Cardioverter-Defibrillator , pp. 135-152
    • Irnich, W.1
  • 30
    • 0028926798 scopus 로고
    • Optimal truncation of defibrillation pulses
    • Irnich W: Optimal truncation of defibrillation pulses. PACE 1995;18:673-688.
    • (1995) PACE , vol.18 , pp. 673-688
    • Irnich, W.1
  • 31
    • 0017717658 scopus 로고
    • Transthoracic ventricular defibrillation in the 100 kg calf with unidirectional rectangular pulses
    • Gold JH, Schuder JC, Stoeckle H, et al: Transthoracic ventricular defibrillation in the 100 kg calf with unidirectional rectangular pulses. Circulation 1977;56:745-750.
    • (1977) Circulation , vol.56 , pp. 745-750
    • Gold, J.H.1    Schuder, J.C.2    Stoeckle, H.3
  • 32
    • 0019206011 scopus 로고
    • Bipolar catheter defibrillation in dogs using trapezoidal waveforms of various tilts
    • Wessale JL, Bourland JD, Tacker WA, et al: Bipolar catheter defibrillation in dogs using trapezoidal waveforms of various tilts. J Electrocardiol 1980;13:359-365.
    • (1980) J Electrocardiol , vol.13 , pp. 359-365
    • Wessale, J.L.1    Bourland, J.D.2    Tacker, W.A.3
  • 33
    • 0020605218 scopus 로고
    • Efficacy and safety of defibrillation with rectangular waves of 2- To 20-milliseconds duration
    • Niebauer MJ, Babbs CF, Geddes LA, et al: Efficacy and safety of defibrillation with rectangular waves of 2- to 20-milliseconds duration. Crit Care Med 1983; 11:95-98.
    • (1983) Crit Care Med , vol.11 , pp. 95-98
    • Niebauer, M.J.1    Babbs, C.F.2    Geddes, L.A.3
  • 34
    • 0022037126 scopus 로고
    • Fundamental criteria underlying the efficacy and safety of defibrillating current waveforms
    • Geddes LA, Niebauer MJ, Babbs CF, et al: Fundamental criteria underlying the efficacy and safety of defibrillating current waveforms. Med Biol Eng Comp 1985;23:122-130.
    • (1985) Med Biol Eng Comp , vol.23 , pp. 122-130
    • Geddes, L.A.1    Niebauer, M.J.2    Babbs, C.F.3
  • 35
    • 0025637041 scopus 로고
    • Strength-duration and probability of success curves for defibrillation with biphasic waveforms
    • Feeser SA, Tang AS, Kavanagh KM, et al: Strength-duration and probability of success curves for defibrillation with biphasic waveforms. Circulation 1990;82: 2128-2141.
    • (1990) Circulation , vol.82 , pp. 2128-2141
    • Feeser, S.A.1    Tang, A.S.2    Kavanagh, K.M.3
  • 36
    • 0027453975 scopus 로고
    • Optimization of biphasic waveforms for human nonthoracotomy defibrillation
    • Swartz JF, Fletcher RD, Karasik PE: Optimization of biphasic waveforms for human nonthoracotomy defibrillation. Circulation 1993;88:2646-2654.
    • (1993) Circulation , vol.88 , pp. 2646-2654
    • Swartz, J.F.1    Fletcher, R.D.2    Karasik, P.E.3
  • 37
    • 4243512616 scopus 로고
    • The effect of biphasic shock waveform tilt upon defibrillation efficacy
    • Li HG, Yee R, Mehra R, et al: The effect of biphasic shock waveform tilt upon defibrillation efficacy. (Abstract) Circulation 1993;88:I-113.
    • (1993) Circulation , vol.88
    • Li, H.G.1    Yee, R.2    Mehra, R.3
  • 38
    • 8544284066 scopus 로고
    • Effects of tilt on biphasic defibrillation efficacy in patients
    • Natale A, VanHout W, DeGroot P, et al: Effects of tilt on biphasic defibrillation efficacy in patients. (Abstract) Circulation 1993;88:I-114.
    • (1993) Circulation , vol.88
    • Natale, A.1    Vanhout, W.2    DeGroot, P.3
  • 39
    • 85024993122 scopus 로고
    • Improved biphasic defibrillation with a lower first phase tilt
    • Hahn SJ, Heil JE, Lin Y, et al: Improved biphasic defibrillation with a lower first phase tilt. (Abstract) Circulation 1994;90:I-175.
    • (1994) Circulation , vol.90
    • Hahn, S.J.1    Heil, J.E.2    Lin, Y.3
  • 40
    • 0028034988 scopus 로고
    • A minimal model of the single capacitor biphasic defibrillation waveform
    • Kroll MW: A minimal model of the single capacitor biphasic defibrillation waveform. PACE 1994;17: 1782-1792.
    • (1994) PACE , vol.17 , pp. 1782-1792
    • Kroll, M.W.1
  • 41
    • 8544275810 scopus 로고
    • Reduction of defibrillation energy requirements with a new biphasic waveform
    • Tchou PJ, Krum D, Akhtar M, et al: Reduction of defibrillation energy requirements with a new biphasic waveform. (Abstract) PACE 1990;13:506.
    • (1990) PACE , vol.13 , pp. 506
    • Tchou, P.J.1    Krum, D.2    Akhtar, M.3
  • 42
    • 8544240106 scopus 로고
    • Repolarization resynchronization may underline the efficacy of biphasic shocks
    • Wang T, Kwaku KF, Dillon SM: Repolarization resynchronization may underline the efficacy of biphasic shocks. (Abstract) Circulation 1994;90:I-446.
    • (1994) Circulation , vol.90
    • Wang, T.1    Kwaku, K.F.2    Dillon, S.M.3
  • 43
    • 8544262912 scopus 로고
    • Does the synchrony of repolarization after monophasic and biphasic field stimuation differ?
    • Sobie EA, Tung L: Does the synchrony of repolarization after monophasic and biphasic field stimuation differ? (Abstract) PACE 1995;18:808.
    • (1995) PACE , vol.18 , pp. 808
    • Sobie, E.A.1    Tung, L.2
  • 44
    • 8544279960 scopus 로고    scopus 로고
    • Dispersion of repolarization prior to electrical ventricular defibrillation predicts outcome
    • Matula MH, Fong S, Brooks MJ, et al: Dispersion of repolarization prior to electrical ventricular defibrillation predicts outcome. (Abstract) PACE 1996; 19:623.
    • (1996) PACE , vol.19 , pp. 623
    • Matula, M.H.1    Fong, S.2    Brooks, M.J.3
  • 45
    • 0029020832 scopus 로고
    • Responses of the transmembrane potential of myocardial cells during a shock
    • Zhou X, Rollins DL, Smith WM, et al: Responses of the transmembrane potential of myocardial cells during a shock. J Cardiovasc Electrophysiol 1995;6:252-263.
    • (1995) J Cardiovasc Electrophysiol , vol.6 , pp. 252-263
    • Zhou, X.1    Rollins, D.L.2    Smith, W.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.