메뉴 건너뛰기




Volumn 19, Issue 4, 1997, Pages 387-393

Low frequency distortions of the electrocardiogram

Author keywords

A.C. amplifier; Backward filtering; Electrocardiogram; Filtering; Low frequency components; QRS complex; ST segment distortions; Time constant

Indexed keywords

AMPLIFIERS (ELECTRONIC); HIGH PASS FILTERS; PHASE SHIFT; SIGNAL DETECTION; SIGNAL DISTORTION; SIGNAL FILTERING AND PREDICTION;

EID: 0031171994     PISSN: 13504533     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1350-4533(96)00074-4     Document Type: Article
Times cited : (7)

References (19)
  • 1
    • 84938013158 scopus 로고
    • Recommendation for instruments in electrocardiography and vectorcardiography
    • Subcommittee on Instrumentation Committee on Electrocardiography - American Heart Association, Recommendation for instruments in electrocardiography and vectorcardiography. IEEE Transactions on Biomedical Engineering, 1967, 14, 60-68.
    • (1967) IEEE Transactions on Biomedical Engineering , vol.14 , pp. 60-68
  • 3
    • 0014981050 scopus 로고
    • Self balancing system for medical and physiological instrumentation
    • Cohen, A. and Longin, R. L., Self balancing system for medical and physiological instrumentation. IEEE Transactions on Biomedical Engineering, 1971, 18, 66-69.
    • (1971) IEEE Transactions on Biomedical Engineering , vol.18 , pp. 66-69
    • Cohen, A.1    Longin, R.L.2
  • 4
    • 0020001518 scopus 로고
    • Digital FIR filtering for removal of ECG baseline wander
    • Marques De Sa, J. P., Digital FIR filtering for removal of ECG baseline wander. Journal of Clinical Engineering, 1982, 7, 235-240.
    • (1982) Journal of Clinical Engineering , vol.7 , pp. 235-240
    • De Marques Sa, J.P.1
  • 5
    • 0022270421 scopus 로고
    • Removal of baseline wander and powerline interference from the ECG by an efficient FIR filter with reduced number of taps
    • Van Alsté, A. and Schilden, T. S., Removal of baseline wander and powerline interference from the ECG by an efficient FIR filter with reduced number of taps. IEEE Transactions on Biomedical Engineering, 1985, 32, 1052-1060.
    • (1985) IEEE Transactions on Biomedical Engineering , vol.32 , pp. 1052-1060
    • Van Alsté, A.1    Schilden, T.S.2
  • 6
    • 0020362241 scopus 로고
    • Ein universeller messverstarker mit DC kompensationsvergleicher auflosung allen messbereichen
    • Moller, D., Ein universeller Messverstarker mit DC Kompensationsvergleicher Auflosung allen Messbereichen. Biomedizinische Technik, 1982, 27, 147-152.
    • (1982) Biomedizinische Technik , vol.27 , pp. 147-152
    • Moller, D.1
  • 9
    • 0013920022 scopus 로고
    • The low frequency response of electrocardiographs, a frequent source of recording errors
    • Berson, A. S. and Pipberger, H. V., The low frequency response of electrocardiographs, a frequent source of recording errors. American Heart Journal, 1966, 71, 779-789.
    • (1966) American Heart Journal , vol.71 , pp. 779-789
    • Berson, A.S.1    Pipberger, H.V.2
  • 11
    • 0023966279 scopus 로고
    • Ambulatory monitoring of the ST segment using direct-recording Holter systems
    • Brose, J., Flachenecker, G. and Frey, A., Ambulatory monitoring of the ST segment using direct-recording Holter systems. Medical Instrumentation, 1988, 22, 2-11.
    • (1988) Medical Instrumentation , vol.22 , pp. 2-11
    • Brose, J.1    Flachenecker, G.2    Frey, A.3
  • 12
    • 0021837982 scopus 로고
    • Artefactual ST abnormalities due to electrocardiographic design
    • Taylor, D. I. and Vincent, R., Artefactual ST abnormalities due to electrocardiographic design. British Heart Journal, 1985, 54, 121-128.
    • (1985) British Heart Journal , vol.54 , pp. 121-128
    • Taylor, D.I.1    Vincent, R.2
  • 13
    • 0017580006 scopus 로고
    • ECG baseline stabilisation for screening analysis
    • Daskalov, I., Tomov, I. and Tomov, L., ECG baseline stabilisation for screening analysis. Advances in Cardiology, 1977, 19, 144-146.
    • (1977) Advances in Cardiology , vol.19 , pp. 144-146
    • Daskalov, I.1    Tomov, I.2    Tomov, L.3
  • 16
    • 0343584340 scopus 로고
    • Enlargement and hypertrophy
    • ed. P. W. Macfarlane and T. D. V. Lawrie. Pergamon Press, Oxford
    • Milliken, J. A., Macfarlane, P. W. and Lawrie, T. D. V., Enlargement and hypertrophy. In Comprehensive Electrocardiology, Vol. 1, ed. P. W. Macfarlane and T. D. V. Lawrie. Pergamon Press, Oxford, 1989, pp. 631-670.
    • (1989) Comprehensive Electrocardiology , vol.1 , pp. 631-670
    • Milliken, J.A.1    Macfarlane, P.W.2    Lawrie, T.D.V.3
  • 18
    • 0014140497 scopus 로고
    • Computer equalisation of low frequency components in tape recorder electrocardiographic signals
    • Arzbaecher, R. C., Woolsey, M. D. and Brody, D. A., Computer equalisation of low frequency components in tape recorder electrocardiographic signals. IEEE Transactions on Biomedical Engineering, 1969, 14, 252-257.
    • (1969) IEEE Transactions on Biomedical Engineering , vol.14 , pp. 252-257
    • Arzbaecher, R.C.1    Woolsey, M.D.2    Brody, D.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.