메뉴 건너뛰기




Volumn 4, Issue 4, 1998, Pages 175-179

The diagnostic accuracy of 0.2 Tesla dedicated MRI in traumatology;Die diagnostische sicherheit von 0.2 Tesla dedizierten MRT niederfeldgeraten in der traumatologie

Author keywords

Dedicated systems; Diagnostic accuracy; Image quality; Low field strength 0.2 Tesla; MRI

Indexed keywords

ADOLESCENT; ADULT; ARTICLE; CLINICAL TRIAL; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; FEMALE; HUMAN; IMAGE QUALITY; JOINT INJURY; MAGNETIC FIELD; MAJOR CLINICAL STUDY; MALE; NUCLEAR MAGNETIC RESONANCE IMAGING; PROSPECTIVE STUDY; TRAUMATOLOGY;

EID: 0031692469     PISSN: 10239332     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (3)

References (21)
  • 1
    • 0030995129 scopus 로고    scopus 로고
    • Imaging of stress injuries to bone. Radiography, scintigraphy and MR imaging
    • Deutsch AL, Coel MN, Mink JH. Imaging of stress injuries to bone. Radiography, scintigraphy and MR imaging. Clin Sports Med 1997; 16:275-90.
    • (1997) Clin Sports Med , vol.16 , pp. 275-290
    • Deutsch, A.L.1    Coel, M.N.2    Mink, J.H.3
  • 2
    • 0030950661 scopus 로고    scopus 로고
    • Accuracy of imaging the menisci on an in-office, dedicated, magnetic resonance imaging extremity system
    • Franklin PD, Lemon RA, Barden HS. Accuracy of imaging the menisci on an in-office, dedicated, magnetic resonance imaging extremity system. Am J Sports Med 1997; 25:382-8.
    • (1997) Am J Sports Med , vol.25 , pp. 382-388
    • Franklin, P.D.1    Lemon, R.A.2    Barden, H.S.3
  • 3
    • 0029982593 scopus 로고    scopus 로고
    • Magnetic resonance imaging of occult scaphoid fractures
    • Gaebler C, Kukla C, Breitenseher M et al. Magnetic resonance imaging of occult scaphoid fractures. J Trauma 1996; 41:73-6.
    • (1996) J Trauma , vol.41 , pp. 73-76
    • Gaebler, C.1    Kukla, C.2    Breitenseher, M.3
  • 4
    • 0030748053 scopus 로고    scopus 로고
    • Diagnosis of lateral ankle ligament injuries: Comparison between talar tilt, MRI and operative findings in 112 athletes
    • Gaebler C, Kukla C, Breitenseher M et al. Diagnosis of lateral ankle ligament injuries: Comparison between talar tilt, MRI and operative findings in 112 athletes. Acta Orthop Scand 1997; 68:286-90
    • (1997) Acta Orthop Scand , vol.68 , pp. 286-290
    • Gaebler, C.1    Kukla, C.2    Breitenseher, M.3
  • 5
    • 0028126072 scopus 로고
    • Magnetic resonance imaging of occult fractures of the proximal femur
    • Harmati N, Staron RB, Barax C et al. Magnetic resonance imaging of occult fractures of the proximal femur. Skeletal Radiol 1994; 23:19-22.
    • (1994) Skeletal Radiol , vol.23 , pp. 19-22
    • Harmati, N.1    Staron, R.B.2    Barax, C.3
  • 6
    • 0030968299 scopus 로고    scopus 로고
    • Economic considerations for the diagnosis and therapy of meniscal lesions: Can magnetic resnonance imaging help reduce the expense?
    • Weinstabl R, Muellner T, Vécsei V et al. Economic considerations for the diagnosis and therapy of meniscal lesions: Can magnetic resnonance imaging help reduce the expense? World J Surg 1997; 21:363-8.
    • (1997) World J Surg , vol.21 , pp. 363-368
    • Weinstabl, R.1    Muellner, T.2    Vécsei, V.3
  • 7
    • 0031241312 scopus 로고    scopus 로고
    • MRT Diagnose von Läsionen am vorderen Kreuzband. Vergleich von 1.0 Tesla und 0.2 Tesla - Erste Ergebnisse
    • Bankier A, Breitenseher M, Trattnig S et al. MRT Diagnose von Läsionen am vorderen Kreuzband. Vergleich von 1.0 Tesla und 0.2 Tesla - erste Ergebnisse. Radiologe 1997; 37:807-11.
    • (1997) Radiologe , vol.37 , pp. 807-811
    • Bankier, A.1    Breitenseher, M.2    Trattnig, S.3
  • 8
    • 0030776033 scopus 로고    scopus 로고
    • MRT bei radiologisch okkulten Kahnbeinfrakturen. Erste Erfahrungen von 1,0 Tesla (Ganzkorper-Mittelgerät) versus 0.2 Tesla (dediziertes Niederfeldgerät)
    • Breitenseher M, Trattnig S, Gäbler C et al. MRT bei radiologisch okkulten Kahnbeinfrakturen. Erste Erfahrungen von 1,0 Tesla (Ganzkorper-Mittelgerät) versus 0.2 Tesla (dediziertes Niederfeldgerät). Radiologe 1997; 37:812-8.
    • (1997) Radiologe , vol.37 , pp. 812-818
    • Breitenseher, M.1    Trattnig, S.2    Gäbler, C.3
  • 9
    • 0028996154 scopus 로고
    • Low-field MR Imaging in patients with clinically suspected acute spinal block
    • Heldman U, Thomsen HS, Mygind T. Low-field MR Imaging in patients with clinically suspected acute spinal block. Acta Radiol 1995; 36:15-8.
    • (1995) Acta Radiol , vol.36 , pp. 15-18
    • Heldman, U.1    Thomsen, H.S.2    Mygind, T.3
  • 10
    • 0030730692 scopus 로고    scopus 로고
    • Vergleich der diagnostischen Sicherheit in der Meniscusdiagnostik von MRT Untersuchungen an einem 0.2 T Niederfeldgerät und 1,5 T Hochfeldsystem
    • Rand T, Imhof H, Breitenseher MJ et al. Vergleich der diagnostischen Sicherheit in der Meniscusdiagnostik von MRT Untersuchungen an einem 0.2 T Niederfeldgerät und 1,5 T Hochfeldsystem. Radiologe 1997; 37:802-6.
    • (1997) Radiologe , vol.37 , pp. 802-806
    • Rand, T.1    Imhof, H.2    Breitenseher, M.J.3
  • 13
    • 0029917470 scopus 로고    scopus 로고
    • Dedicated MR system and acute trauma of the musculoskeletal system
    • Masiciocchi C. Dedicated MR system and acute trauma of the musculoskeletal system. Eur J Radiol 1996; 22:7-13.
    • (1996) Eur J Radiol , vol.22 , pp. 7-13
    • Masiciocchi, C.1
  • 14
    • 0025758415 scopus 로고
    • Ultra low field magnetic resonance imaging of acute cruciate ligament tears
    • Ekelund L, Björnebrink J, Elmquist LG. Ultra low field magnetic resonance imaging of acute cruciate ligament tears. Magn Reson Imaging 1991; 9:179-85.
    • (1991) Magn Reson Imaging , vol.9 , pp. 179-185
    • Ekelund, L.1    Björnebrink, J.2    Elmquist, L.G.3
  • 15
    • 0026001247 scopus 로고
    • Comparison of CT, low-field-strength MR imaging, and high-field-strength MR imaging
    • Orrison WW, Stimac GK, Stevens EA et al. Comparison of CT, low-field-strength MR imaging, and high-field-strength MR imaging. Radiology 1991; 181:121-7.
    • (1991) Radiology , vol.181 , pp. 121-127
    • Orrison, W.W.1    Stimac, G.K.2    Stevens, E.A.3
  • 16
    • 0002072626 scopus 로고
    • Magnetic resonance imaging in the detection of meniscal injuries
    • Loytsch M, Mink J, Crues JV et al. Magnetic resonance imaging in the detection of meniscal injuries. Magn Reson Imaging 1986; 4:185-9.
    • (1986) Magn Reson Imaging , vol.4 , pp. 185-189
    • Loytsch, M.1    Mink, J.2    Crues, J.V.3
  • 17
    • 0029037009 scopus 로고
    • MRT des Kniegelenkes: Erste Ergebnisse eines Vergleiches von 0.2 T- Spezialsy-stem mit 1,5 T Hochfeldmagnet
    • Kersting-Sommerhoff B, Gerhardt P, Golder W et al. MRT des Kniegelenkes: Erste Ergebnisse eines Vergleiches von 0.2 T- Spezialsy-stem mit 1,5 T Hochfeldmagnet. RöFo 1995; 162:390-5.
    • (1995) RöFo , vol.162 , pp. 390-395
    • Kersting-Sommerhoff, B.1    Gerhardt, P.2    Golder, W.3
  • 18
    • 0029688462 scopus 로고    scopus 로고
    • MRI of peripheral joints with a low-field dedicated system: A reliable and cost-effective alternative to hogh-field units
    • Kersting-Sommerhoff B, Hof N, Lenz P et al. MRI of peripheral joints with a low-field dedicated system: A reliable and cost-effective alternative to hogh-field units. Eur Radiol 1996; 6:561-5.
    • (1996) Eur Radiol , vol.6 , pp. 561-565
    • Kersting-Sommerhoff, B.1    Hof, N.2    Lenz, P.3
  • 19
    • 0028924910 scopus 로고
    • Low-field versus high-field MR imaging of the knee: A comparison of signal behaviour and diagnostic performance
    • Parizel PM, Dijkstra HAJ, Geenen GPJ et al. Low-field versus high-field MR imaging of the knee: A comparison of signal behaviour and diagnostic performance. Eur J Radiol 1995; 19:132-8.
    • (1995) Eur J Radiol , vol.19 , pp. 132-138
    • Parizel, P.M.1    Dijkstra, H.A.J.2    Geenen, G.P.J.3
  • 20
    • 0025937139 scopus 로고
    • MR study of normal joint function using a low field strength system
    • Minami M, Yoshikawa Y, Matsuoka Y et al. MR study of normal joint function using a low field strength system. JCAT 1991; 15:1017-23.
    • (1991) JCAT , vol.15 , pp. 1017-1023
    • Minami, M.1    Yoshikawa, Y.2    Matsuoka, Y.3
  • 21
    • 0030730691 scopus 로고    scopus 로고
    • MRT auf Niederfeld-tomographen (0.2 Tesla): Ein quantitativer Vergleich zu einem Gerät mittlerer Feldstärke (1.0 Tesla)
    • Trattnig S, Kontaxis G, Breitenseher M et al. MRT auf Niederfeld-tomographen (0.2 Tesla): Ein quantitativer Vergleich zu einem Gerät mittlerer Feldstärke (1.0 Tesla). Radiologe 1997; 37:773-7.
    • (1997) Radiologe , vol.37 , pp. 773-777
    • Trattnig, S.1    Kontaxis, G.2    Breitenseher, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.