Volumn 6, Issue 4, 1996, Pages 561-565

MRI of peripheral joints with a low-field dedicated system: A reliable and cost-effective alternative to high-field units?

Author keywords

Dedicated MR system; Knee; Low field MRI

Indexed keywords

ACUTE DISEASE; ANKLE; ARTHROPATHY; ARTHROSCOPY; ARTICLE; CHRONIC DISEASE; COMPARATIVE STUDY; COMPUTER PROGRAM; COMPUTER SYSTEM; COST BENEFIT ANALYSIS; COST CONTROL; ECONOMICS; ELBOW; EQUIPMENT DESIGN; HAND; HUMAN; IMAGE ENHANCEMENT; INSTRUMENTATION; KNEE; METHODOLOGY; NUCLEAR MAGNETIC RESONANCE IMAGING; PATHOLOGY; PROSPECTIVE STUDY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; TARSAL JOINT; WRIST;

EID: 0029688462     PISSN: 09387994     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF00182495     Document Type: Article
Times cited : (41)

References (14)
  • 1
    • 0025754211 scopus 로고
    • Magnetic resonance imaging of meniscal and cruciate injuries of the knee
    • Boeree NR, Watkinson AF, Ackroyd CE, Johnson C (1991) Magnetic resonance imaging of meniscal and cruciate injuries of the knee. J Bone Joint Surg 73B: 452-457
    • (1991) J Bone Joint Surg , vol.73 B , pp. 452-457
    • Boeree, N.R.1    Watkinson, A.F.2    Ackroyd, C.E.3    Johnson, C.4
  • 3
    • 0025975858 scopus 로고
    • The clinical value of magnetic resonance imaging in the evaluation of meniscal disorders
    • Raunest J, Oberle K, Loehnert J, Hötzinger H (1991) The clinical value of magnetic resonance imaging in the evaluation of meniscal disorders. J Bone Joint Surg 73: 11-16
    • (1991) J Bone Joint Surg , vol.73 , pp. 11-16
    • Raunest, J.1    Oberle, K.2    Loehnert, J.3    Hötzinger, H.4
  • 4
    • 0027171844 scopus 로고
    • MR diagnosis of internal derangement of the knee: Effect of field strength on efficacy
    • Barnett J (1993) MR diagnosis of internal derangement of the knee: effect of field strength on efficacy. AJR 161: 115-118
    • (1993) AJR , vol.161 , pp. 115-118
    • Barnett, J.1
  • 5
    • 0025202137 scopus 로고
    • MR scanning of the acutely injured knee: Sensitive but is it cost effective?
    • Boden SD, Panos PA, Vailas JC (1990) MR scanning of the acutely injured knee: sensitive but is it cost effective? Arthroscopy 6: 306-310
    • (1990) Arthroscopy , vol.6 , pp. 306-310
    • Boden, S.D.1    Panos, P.A.2    Vailas, J.C.3
  • 7
    • 0028303342 scopus 로고
    • Economic and cost-effectiveness investigations of radiologic practices
    • Powe NR (1994) Economic and cost-effectiveness investigations of radiologic practices. Radiology 192: 11-18
    • (1994) Radiology , vol.192 , pp. 11-18
    • Powe, N.R.1
  • 8
    • 0028269067 scopus 로고
    • New imaging technology and cost containment
    • Hillman BJ (1994) New imaging technology and cost containment. AJR 162: 503-506
    • (1994) AJR , vol.162 , pp. 503-506
    • Hillman, B.J.1
  • 9
    • 0025287925 scopus 로고
    • MR imaging of the knee: A prospective trial using a low field strength magnet
    • James P, Buirski P (1990) MR imaging of the knee: a prospective trial using a low field strength magnet. Australas Radiol 34: 59-63
    • (1990) Australas Radiol , vol.34 , pp. 59-63
    • James, P.1    Buirski, P.2
  • 10
    • 84889549229 scopus 로고
    • MRI of the knee joint-comparison of low field (0.2T) and high field (1.5T) imaging
    • Wien 1994, abstract
    • Kladny B, Glückert K, Swoboda B, Trittor F (1994) MRI of the knee joint-comparison of low field (0.2T) and high field (1.5T) imaging. The 5th SICOT Trainees Meeting, Wien 1994, abstract
    • (1994) The 5th SICOT Trainees Meeting
    • Kladny, B.1    Glückert, K.2    Swoboda, B.3    Trittor, F.4
  • 11
    • 0025375964 scopus 로고
    • MR imaging of the knee with a 0.064 T permanent magnet
    • Rothschild PA, Domesek JM, Kaufman L et al. (1990) MR imaging of the knee with a 0.064 T permanent magnet. Radiology 175: 775-778
    • (1990) Radiology , vol.175 , pp. 775-778
    • Rothschild, P.A.1    Domesek, J.M.2    Kaufman, L.3
  • 13
    • 0029037009 scopus 로고
    • MR Tomographie des Knies. Erste Ergebnisse eines Vergleichs zwischen 0.2T Spezialsystem und 1.5T Hochfeldgerät
    • Kersting-Sommerhoff B, Hof N, Golder W, Riel KA, Gerhardt P (1995) MR Tomographie des Knies. Erste Ergebnisse eines Vergleichs zwischen 0.2T Spezialsystem und 1.5T Hochfeldgerät. Fortschr Röntgenstr 162 (5): 390-395
    • (1995) Fortschr Röntgenstr , vol.162 , Issue.5 , pp. 390-395
    • Kersting-Sommerhoff, B.1    Hof, N.2    Golder, W.3    Riel, K.A.4    Gerhardt, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.