Volumn 13, Issue 3, 1994, Pages 526-537

Precision and Accuracy of Regional Radioactivity Quantitation Using the Maximum Likelihood EM Reconstruction Algorithm

Author keywords

[No Author keywords available]

Indexed keywords

BRAIN; IMAGE CODING; IMAGE QUALITY; IMAGE RECONSTRUCTION; ITERATIVE METHODS; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; POSITRON EMISSION TOMOGRAPHY; RADIOACTIVITY;

EID: 0028496882     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/42.310884     Document Type: Article
Times cited : (52)

References (40)
  • 1
    • 0020194763 scopus 로고
    • Maximum likelihood reconstruction for emission tomography
    • L. A. Shepp and Y. Vardi, “Maximum likelihood reconstruction for emission tomography,” IEEE Trans. Med. Imag., vol. MI-1, pp. 113-122, 1982.
    • (1982) IEEE Trans. Med. Imag. , vol.MI-1 , pp. 113-122
    • Shepp, L.A.1    Vardi, Y.2
  • 2
    • 0021327145 scopus 로고
    • EM reconstruction algorithms for emission and transmission tomography
    • K. Lange and R. Carson, “EM reconstruction algorithms for emission and transmission tomography,” J. Comput. Assist. Tomogr., vol. 8, pp. 306-316, 1984.
    • (1984) J. Comput. Assist. Tomogr. , vol.8 , pp. 306-316
    • Lange, K.1    Carson, R.2
  • 4
    • 0018367149 scopus 로고
    • Quantitation in positron emission computed tomography: 1. Effect of object size
    • E. J. Hoffman, S. C. Huang, and M. E. Phelps, “Quantitation in positron emission computed tomography: 1. Effect of object size,” J. Comput. Assist. Tomogr., vol. 3, 299-308, 1979.
    • (1979) J. Comput. Assist. Tomogr. , vol.3
    • Hoffman, E.J.1    Huang, S.C.2    Phelps, M.E.3
  • 5
    • 0021370790 scopus 로고
    • Maximum-likelihood reconstruction for single-photon emission computed-tomography
    • M. Miller, D. Snyder, and T. Miller, “Maximum-likelihood reconstruction for single-photon emission computed-tomography,” IEEE Trans. Nucl. Sci., vol. NS-32, pp. 769-778, 1985.
    • (1985) IEEE Trans. Nucl. Sci. , vol.NS-32 , pp. 769-778
    • Miller, M.1    Snyder, D.2    Miller, T.3
  • 6
    • 84942486688 scopus 로고
    • Towards a practical implementation of the MLE algorithm
    • J. Llacer, S. Andreae, and E. Veklerov, ' ‘Towards a practical implementation of the MLE algorithm,” IEEE Trans. Med. Imag., vol. 8, pp. 186-193, 1986.
    • (1986) IEEE Trans. Med. Imag. , vol.8 , pp. 186-193
    • Llacer, J.1    Andreae, S.2    Veklerov, E.3
  • 7
    • 0022683404 scopus 로고
    • Accelerated iterative reconstruction for positron emission tomography based on the EM algorithm for maximum likelihood estimation
    • R. Lewitt and G. Muehllehner, “Accelerated iterative reconstruction for positron emission tomography based on the EM algorithm for maximum likelihood estimation,” IEEE Trans. Med. Imag., vol. MI-5, pp. 16-22, 1986.
    • (1986) IEEE Trans. Med. Imag. , vol.MI-5 , pp. 16-22
    • Lewitt, R.1    Muehllehner, G.2
  • 8
    • 0023314408 scopus 로고
    • Implementing and accelerating the EM algorithm for positron emission tomography
    • L. Kaufman, “Implementing and accelerating the EM algorithm for positron emission tomography,” IEEE Trans. Med. Imag., vol. 6, pp. 37-51, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 37-51
    • Kaufman, L.1
  • 9
    • 0023422273 scopus 로고
    • Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography
    • D. Snyder, M. Miller, L. Thomas, and D. Politte, “Noise and edge artifacts in maximum-likelihood reconstructions for emission tomography,” IEEE Trans. Med. Imag., vol.,6, pp. 228-238, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 228-238
    • Snyder, D.1    Miller, M.2    Thomas, L.3    Politte, D.4
  • 10
    • 0023363465 scopus 로고
    • A fast reconstruction algorithm for stationary positron emission tomography based on a modified EM algorithm
    • E. Tanaka, “A fast reconstruction algorithm for stationary positron emission tomography based on a modified EM algorithm,” IEEE Trans. Med. Imag., vol. 6, pp. 98-105, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 98-105
    • Tanaka, E.1
  • 11
    • 0025419552 scopus 로고
    • Image improvements in positron-emission tomography due to measuring differential time-of-flight and using maximum-likelihood estimation
    • D. Politte, “Image improvements in positron-emission tomography due to measuring differential time-of-flight and using maximum-likelihood estimation,” IEEE Trans. Med. vol. 37, 737-742, 1990.
    • (1990) IEEE Trans. Med. , vol.37 , pp. 737-742
    • Politte, D.1
  • 12
    • 0025814380 scopus 로고
    • The use of cross-validation as a stopping rule in emission tomography image reconstruction
    • K. Coakley and J. Llacer, “The use of cross-validation as a stopping rule in emission tomography image reconstruction,” in SPIE Medical Imaging V. pp. 226-233, 1991.
    • (1991) SPIE Medical Imaging V. , pp. 226-233
    • Coakley, K.1    Llacer, J.2
  • 13
    • 0026121689 scopus 로고
    • Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography
    • D. Politte and D. Snyder, “Corrections for accidental coincidences and attenuation in maximum-likelihood image reconstruction for positron-emission tomography,” IEEE Trans. Med. Imag., vol. 10, pp. 82-89, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 82-89
    • Politte, D.1    Snyder, D.2
  • 14
    • 0020702884 scopus 로고
    • Utilizing side information in emission tomography
    • D. Snyder, “Utilizing side information in emission tomography,” IEEE Trans. Med. Imag., vol. NS-31, pp. 533-537, 1984.
    • (1984) IEEE Trans. Med. Imag. , vol.NS-31 , pp. 533-537
    • Snyder, D.1
  • 15
    • 0023421482 scopus 로고
    • A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography
    • E. Levitan and G. Herman, “A maximum a posteriori probability expectation maximization algorithm for image reconstruction in emission tomography,” IEEE Trans. Med. Imag., vol. 6, pp. 185-192, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 185-192
    • Levitan, E.1    Herman, G.2
  • 16
    • 0024738904 scopus 로고
    • On Bayesian image reconstruction from projections: Uniform and nonuniform a priori source information
    • Z. Liang, R. Jaszczak, and K. Greer, “On Bayesian image reconstruction from projections: Uniform and nonuniform a priori source information,” IEEE Trans. Med. Imag., vol. 8, pp. 227-235, 1989.
    • (1989) IEEE Trans. Med. Imag. , vol.8 , pp. 227-235
    • Liang, Z.1    Jaszczak, R.2    Greer, K.3
  • 17
    • 0025414894 scopus 로고
    • Bayesian image reconstruction in positron emission tomography
    • C. Chen, V. Johnson, W. Wong, X. Hu, and C. Metz, “Bayesian image reconstruction in positron emission tomography,” IEEE Trans. Med. Imag., vol. 37, pp. 636-641, 1990.
    • (1990) IEEE Trans. Med. Imag. , vol.37 , pp. 636-641
    • Chen, C.1    Johnson, V.2    Wong, W.3    Hu, X.4    Metz, C.5
  • 18
    • 0025587714 scopus 로고
    • Convergence of EM image reconstruction algorithms with Gibbs smoothing
    • K. Lange, “Convergence of EM image reconstruction algorithms with Gibbs smoothing,” IEEE Trans. Med. Imag., vol. 9, 439-446, 1990.
    • (1990) IEEE Trans. Med. Imag. , vol.9 , pp. 439-446
    • Lange, K.1
  • 19
    • 0025447299 scopus 로고
    • A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images
    • J. Nunez and J. Llacer, “A fast Bayesian reconstruction algorithm for emission tomography with entropy prior converging to feasible images,” IEEE Trans. Med. Imag., vol. 9, pp. 159-171, 1990.
    • (1990) IEEE Trans. Med. Imag. , vol.9 , pp. 159-171
    • Nunez, J.1    Llacer, J.2
  • 20
    • 0026406219 scopus 로고
    • Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions
    • J. Liow and S. Strother, “Practical tradeoffs between noise, quantitation, and number of iterations for maximum likelihood-based reconstructions,” IEEE Trans. Med. Imag., vol. 10, 563-571, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 563-571
    • Liow, J.1    Strother, S.2
  • 21
    • 84942484854 scopus 로고
    • Performance of maximum likelihood based image reconstruction for quantitative imaging
    • J. S. Liow and S. C. Strother, “Performance of maximum likelihood based image reconstruction for quantitative imaging,” in IEEE Nuclear Science Symp. and Medical Imaging Conf., pp. 2078-2083, 1991.
    • (1991) IEEE Nuclear Science Symp. and Medical Imaging Conf. , pp. 2078-2083
    • Liow, J.S.1    Strother, S.C.2
  • 22
    • 0022536597 scopus 로고
    • A maximum likelihood method for region-of-interest evaluation in emission tomography
    • R. E. Carson, “A maximum likelihood method for region-of-interest evaluation in emission tomography,” J. Comput. Assist. Tomogr., vol. 10, pp. 654-663, 1986.
    • (1986) J. Comput. Assist. Tomogr. , vol.10 , pp. 654-663
    • Carson, R.E.1
  • 23
    • 84942487426 scopus 로고
    • Evaluation of a fast maximum likelihood method for estimation of region-of-interest values in emission tomography
    • R. E. Carson, G. W. Berg, M. V. Green, and S. M. Larson, “Evaluation of a fast maximum likelihood method for estimation of region-of-interest values in emission tomography,” J. Nucl. Med., vol. 27, 895, 1986.
    • (1986) J. Nucl. Med. , vol.27
    • Carson, R.E.1    Berg, G.W.2    Green, M.V.3    Larson, S.M.4
  • 25
    • 0026121711 scopus 로고
    • Performance evaluation of the PC-2048: A new 15-slice encoded-crystal PET scanner for neurological studies
    • A. C. Evans, C. J. Thompson, S. Marrett, E. Meyer, and M. Mazza, “Performance evaluation of the PC-2048: A new 15-slice encoded-crystal PET scanner for neurological studies,” IEEE Trans. Med. Imag., vol. 10, pp. 90-98, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 90-98
    • Evans, A.C.1    Thompson, C.J.2    Marrett, S.3    Meyer, E.4    Mazza, M.5
  • 26
    • 0020660172 scopus 로고
    • Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections
    • M. Bergstrom, L. Eriksson, C. Bohm, G. Blomqvist, and J. Litton, “Correction for scattered radiation in a ring detector positron camera by integral transformation of the projections,” J. Comput. Assist. Tomogr., vol. 7, pp. 42-50, 1983.
    • (1983) J. Comput. Assist. Tomogr. , vol.7 , pp. 42-50
    • Bergstrom, M.1    Eriksson, L.2    Bohm, C.3    Blomqvist, G.4    Litton, J.5
  • 27
    • 0023421618 scopus 로고
    • Errors in reprojection methods in computerized tomography
    • H. Trussell, H. Orun-Ozturk, and M. Civanlar, “Errors in reprojection methods in computerized tomography,” IEEE Trans. Med. Imag., vol. 6, pp. 220-227, 1987.
    • (1987) IEEE Trans. Med. Imag. , vol.6 , pp. 220-227
    • Trussell, H.1    Orun-Ozturk, H.2    Civanlar, M.3
  • 28
    • 0026392246 scopus 로고
    • Parallelization of the EM algorithm for 3-D PET image reconstruction
    • C. Chen, S. Lee, and Z. Cho, “Parallelization of the EM algorithm for 3-D PET image reconstruction,” IEEE Trans. Med. Imag., vol. 10, pp. 513-522, 1991.
    • (1991) IEEE Trans. Med. Imag. , vol.10 , pp. 513-522
    • Chen, C.1    Lee, S.2    Cho, Z.3
  • 30
    • 0027398350 scopus 로고
    • The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction
    • J. S. Liow and S. C. Strother, “The convergence of object dependent resolution in maximum likelihood based tomographic image reconstruction,” Phys. Med. Biol., vol. 38, pp. 55-70, 1993.
    • (1993) Phys. Med. Biol. , vol.38 , pp. 55-70
    • Liow, J.S.1    Strother, S.C.2
  • 31
    • 0025414253 scopus 로고
    • Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts
    • S. C. Strother, M. E. Casey, and E. J. Hoffman, “Measuring PET scanner sensitivity: Relating countrates to image signal-to-noise ratios using noise equivalent counts,” IEEE Trans. Med. Imag., vol. 37, pp. 783-788, 1990.
    • (1990) IEEE Trans. Med. Imag. , vol.37 , pp. 783-788
    • Strother, S.C.1    Casey, M.E.2    Hoffman, E.J.3
  • 32
    • 0023684146 scopus 로고
    • Anatomical-functional correlation using an adjustable MRI-based region of interest atlas with positron emission tomography
    • A. C. Evans, C. Beil, S. Marrett, C. J. Thompson, and A. Hakim, “Anatomical-functional correlation using an adjustable MRI-based region of interest atlas with positron emission tomography,” J. Cereb. Blood Flow Metab., vol. 8, pp. 513-530, 1988.
    • (1988) J. Cereb. Blood Flow Metab. , vol.8 , pp. 513-530
    • Evans, A.C.1    Beil, C.2    Marrett, S.3    Thompson, C.J.4    Hakim, A.5
  • 33
    • 0010240533 scopus 로고
    • An optimized maximum likelihood approach to positron emission tomography reconstruction
    • J. S. Coakley and J. Llacer, “An optimized maximum likelihood approach to positron emission tomography reconstruction,” in IEEE Nuclear Science Symp. and Medical Imaging Conf., pp. 2084-2088, 1991.
    • (1991) IEEE Nuclear Science Symp. and Medical Imaging Conf. , pp. 2084-2088
    • Coakley, J.S.1    Llacer, J.2
  • 34
    • 84942485855 scopus 로고
    • Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images
    • D. W. Wilson and B. M. W. Tsui, “Noise properties of filtered-backprojection and ML-EM reconstructed emission tomographic images,” in IEEE Nuclear Science Symp. and Medical Imaging Conf. pp. 1114-1116, 1992.
    • (1992) IEEE Nuclear Science Symp. and Medical Imaging Conf. , pp. 1114-1116
    • Wilson, D.W.1    Tsui, B.M.W.2
  • 35
    • 11744258349 scopus 로고
    • Noise and signal decoupling in maximum likelihood reconstructions and Metz filters for PET images
    • J. S. Liow and S. C. Strother, “Noise and signal decoupling in maximum likelihood reconstructions and Metz filters for PET images,” in IEEE Nuclear Science Symp. and Medical Imaging Conf. pp. 901-903, 1992.
    • (1992) IEEE Nuclear Science Symp. and Medical Imaging Conf. , pp. 901-903
    • Liow, J.S.1    Strother, S.C.2
  • 36
    • 0021059165 scopus 로고
    • Effect of tissue heterogeneity on the measurement of cerebral blood flow with the equilibrium C1502 inhalation technique
    • P. Herscovitch and M. E. Raichle, “Effect of tissue heterogeneity on the measurement of cerebral blood flow with the equilibrium C1502 inhalation technique,” J. Cereb. Blood Flow Metab., vol. 3, pp. 407-415, 1983.
    • (1983) J. Cereb. Blood Flow Metab. , vol.3 , pp. 407-415
    • Herscovitch, P.1    Raichle, M.E.2
  • 37
    • 0026784876 scopus 로고
    • Errors introduced by tissue heterogeneity in estimation of local cerebral glucose utilization with current kinetic models of the [18F] fluorodeoxyglucose method
    • K. Schmidt, G. Lucignani, R. M. Moresco, G. Rizzo, M. C. Gilardi, C. Messa, F. Colombo, F. Fazio, and L. Sokoloff, “Errors introduced by tissue heterogeneity in estimation of local cerebral glucose utilization with current kinetic models of the [18F] fluorodeoxyglucose method,” J. Cereb. Blood Flow Metab., vol. 12, pp. 823-834, 1992.
    • (1992) J. Cereb. Blood Flow Metab. , vol.12 , pp. 823-834
    • Schmidt, K.1    Lucignani, G.2    Moresco, R.M.3    Rizzo, G.4    Gilardi, M.C.5    Messa, C.6    Colombo, F.7    Fazio, F.8    Sokoloff, L.9
  • 39
    • 0025287084 scopus 로고
    • Correction of PET data for partial volume effects in human cerebral cortex by MR imaging
    • May
    • C. C. Meltzer, J. P. Leal, H. S. Mayberg, H. N. Wagner, and J. J. Frost, “Correction of PET data for partial volume effects in human cerebral cortex by MR imaging,” J. Comput. Assist. Tomogr., vol. 14, pp. 561-570, 1990.
    • (1990) J. Comput. Assist. Tomogr. , vol.14 , pp. 561-570
    • Meltzer, C.C.1    Leal, J.P.2    Mayberg, H.S.3    Wagner, H.N.4    Frost, J.J.5
  • 40
    • 0026700928 scopus 로고
    • Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects
    • H. W. Muller-Gartner, J. M. Links, J. L. Prince, R. N. Bryan, E. McVeigh, J. P. Leal, C. Davatzikos, and J. J. Frost, “Measurement of radiotracer concentration in brain gray matter using positron emission tomography: MRI-based correction for partial volume effects,” J. Cereb. Blood Flow Metab., vol. 12, pp. 571-583, 1992.
    • (1992) J. Cereb. Blood Flow Metab. , vol.12 , pp. 571-583
    • Muller-Gartner, H.W.1    Links, J.M.2    Prince, J.L.3    Bryan, R.N.4    McVeigh, E.5    Leal, J.P.6    Davatzikos, C.7    Frost, J.J.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.