메뉴 건너뛰기




Volumn 52, Issue 2, 1997, Pages 231-239

Ion deposition experiments as a tool for the study of the spatial distribution of analyte ions in the second vacuum stage of an inductively coupled plasma mass spectrometer

Author keywords

ICP MS; Ion beam; Space charge

Indexed keywords

ATOMS; DEPOSITION; ELECTRIC SPACE CHARGE; FLUORESCENCE; ION BEAMS; NICKEL; PARTICLES (PARTICULATE MATTER); PLASMA APPLICATIONS; SCANNING ELECTRON MICROSCOPY; VACUUM; X RAY SPECTROSCOPY;

EID: 0031074017     PISSN: 05848547     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0584-8547(96)01576-5     Document Type: Article
Times cited : (19)

References (12)
  • 1
    • 0002204069 scopus 로고
    • Matrix-effect observations in inductively coupled plasma mass spectrometry
    • S.H. Tan and G. Horlick, Matrix-effect observations in inductively coupled plasma mass spectrometry, J. Anal. Atom. Spectrom., 2 (1987) 745.
    • (1987) J. Anal. Atom. Spectrom. , vol.2 , pp. 745
    • Tan, S.H.1    Horlick, G.2
  • 2
    • 45949127897 scopus 로고
    • Study of the effects of concomitant elements in inductively coupled plasma mass spectrometry
    • D. Beauchemin, J.W. McLaren and S.S. Berman, Study of the effects of concomitant elements in inductively coupled plasma mass spectrometry, Spectrochim. Acta, Part B, 42 (1987) 467.
    • (1987) Spectrochim. Acta, Part B , vol.42 , pp. 467
    • Beauchemin, D.1    McLaren, J.W.2    Berman, S.S.3
  • 3
    • 0000758476 scopus 로고
    • Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry
    • G.R. Gillson, D.J. Douglas, J.E. Fulford, K.W. Halligan and S.D. Tanner, Nonspectroscopic interelement interferences in inductively coupled plasma mass spectrometry, Anal. Chem., 60 (1988) 1472.
    • (1988) Anal. Chem. , vol.60 , pp. 1472
    • Gillson, G.R.1    Douglas, D.J.2    Fulford, J.E.3    Halligan, K.W.4    Tanner, S.D.5
  • 4
    • 0001530559 scopus 로고
    • Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer - III. Monitoring the ion beam
    • D.M. Chambers, B.S. Ross and G.M. Hieftje, Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer - III. Monitoring the ion beam, Spectrochim. Acta, Part B, 46 (1991) 785.
    • (1991) Spectrochim. Acta, Part B , vol.46 , pp. 785
    • Chambers, D.M.1    Ross, B.S.2    Hieftje, G.M.3
  • 5
    • 0008919949 scopus 로고
    • Alteration of the ion-optic lens configuration to eliminate mass-dependent matrix-interference effects in inductively coupled plasma-mass spectrometry
    • B.S. Ross and G.M. Hieftje, Alteration of the ion-optic lens configuration to eliminate mass-dependent matrix-interference effects in inductively coupled plasma-mass spectrometry, Spectrochim. Acta, Part B, 46 (1991) 1263.
    • (1991) Spectrochim. Acta, Part B , vol.46 , pp. 1263
    • Ross, B.S.1    Hieftje, G.M.2
  • 6
    • 0026875967 scopus 로고
    • Space charge in ICP-MS: Calculations and implications
    • S.D. Tanner, Space charge in ICP-MS: calculations and implications, Spectrochim. Acta, Part B, 47 (1992) 809.
    • (1992) Spectrochim. Acta, Part B , vol.47 , pp. 809
    • Tanner, S.D.1
  • 7
    • 37049077622 scopus 로고
    • Gas dynamics of the inductively coupled plasma mass spectrometry interface
    • D.J. Douglas and J.B. French, Gas dynamics of the inductively coupled plasma mass spectrometry interface, J. Anal. Atom. Spectrom., 3 (1988) 743.
    • (1988) J. Anal. Atom. Spectrom. , vol.3 , pp. 743
    • Douglas, D.J.1    French, J.B.2
  • 8
    • 0001530557 scopus 로고
    • Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer - I. Langmuir probe measurements
    • D.M. Chambers, J. Poehlman, P. Yang and G.M. Hieftje, Fundamental studies of the sampling process in an inductively coupled plasma mass spectrometer - I. Langmuir probe measurements, Spectrochim. Acta, Part B, 46 (1991) 741.
    • (1991) Spectrochim. Acta, Part B , vol.46 , pp. 741
    • Chambers, D.M.1    Poehlman, J.2    Yang, P.3    Hieftje, G.M.4
  • 9
    • 0041322317 scopus 로고    scopus 로고
    • Spatially resolved measurements of ion density behind the skimmer of an inductively coupled plasma mass spectrometer
    • X. Chen and R.S. Houk, Spatially resolved measurements of ion density behind the skimmer of an inductively coupled plasma mass spectrometer, Spectrochim. Acta, Part B, 51 (1996) 41.
    • (1996) Spectrochim. Acta, Part B , vol.51 , pp. 41
    • Chen, X.1    Houk, R.S.2
  • 10
    • 0029035760 scopus 로고
    • Space-charge effects and ion distribution in plasma source mass spectrometry
    • G. Li, Y. Dang and G.M. Hiefje, Space-charge effects and ion distribution in plasma source mass spectrometry, J. Mass Spectrom., 30 (1995) 841.
    • (1995) J. Mass Spectrom. , vol.30 , pp. 841
    • Li, G.1    Dang, Y.2    Hiefje, G.M.3
  • 12
    • 0030191015 scopus 로고    scopus 로고
    • Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry
    • H. Niu and R.S. Houk, Fundamental aspects of ion extraction in inductively coupled plasma mass spectrometry, Spectrochim. Acta, Part B, 51 (1996) 779.
    • (1996) Spectrochim. Acta, Part B , vol.51 , pp. 779
    • Niu, H.1    Houk, R.S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.