-
1
-
-
85027176849
-
-
1989.
-
S. Schneider, K. Abraham-Fuchs, G. Daalmans, W. Folberth, H. E. Hoenig, H. Reichenberger, G. Rohrlein, H. Seifen, and A. Wirth, "Development and performance of a multichannel system for studies of biomagnetic signals of brain and heart," in Adv. Biomagnetism, eds. S. J. Williamson et al., New York: Plenum Press, pp. 669-672, 1989.
-
K. Abraham-Fuchs, G. Daalmans, W. Folberth, H. E. Hoenig, H. Reichenberger, G. Rohrlein, H. Seifen, and A. Wirth, "Development and Performance of a Multichannel System for Studies of Biomagnetic Signals of Brain and Heart," in Adv. Biomagnetism, Eds. S. J. Williamson Et Al., New York: Plenum Press, Pp. 669-672
-
-
Schneider, S.1
-
2
-
-
0026124444
-
-
1991.
-
A.I. Ahonen, M.S. Hämäläinen, M. J. Kajola, J. E. T. Knuutila, O. V. Lounasmma, J. T. Simola, C. D. Tesche, and V. A. Vilkman, "Multichannel SQUID system for brain research," IEEE Trans. Magn. vol.27, pp. 2786-2792, 1991.
-
M.S. Hämäläinen, M. J. Kajola, J. E. T. Knuutila, O. V. Lounasmma, J. T. Simola, C. D. Tesche, and V. A. Vilkman, "Multichannel SQUID System for Brain Research," IEEE Trans. Magn. Vol.27, Pp. 2786-2792
-
-
Ahonen, A.I.1
-
3
-
-
85027156247
-
-
14th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. (Lyon), pp. 46-50, 1992.
-
D. Cheyne, J. Vrba, D. Crisp, K. Betts, M. Burbank, T. Cheung, A. Fife, G. Haid, P. Kubik, S. Lee, J. McCubbin, J. Mckay, D. Mckenzie, P. Spear, B. Taylor, M. Tillotson, H. Weinberg, E. Basar, and T. Tsuda, "Use of an unshielded, 64-channel whole-cortex MEG system in the study of normal and pathological brain function," in Proc. Satel. Symp. Neurosci. Technol., 14th Ann. Int. Conf. IEEE Eng. Med. Biol. Soc. (Lyon), pp. 46-50, 1992.
-
Use of an Unshielded, 64-channel Whole-cortex MEG System in the Study of Normal and Pathological Brain Function," in Proc. Satel. Symp. Neurosci. Technol.
-
-
Cheyne, D.1
Vrba, J.2
Crisp, D.3
Betts, K.4
Burbank, M.5
Cheung, T.6
Fife, A.7
Haid, G.8
Kubik, P.9
Lee S10
McCubbin, J.11
Mckay, J.12
Mckenzie, D.13
Spear, P.14
Taylor, B.15
Tillotson, M.16
Weinberg, H.17
Basar, E.18
Tsuda, T.19
-
4
-
-
0027559055
-
-
1993.
-
O. Dössei, S. David, M. Fuchs, J. Kruger, K. -M. LUdeke, and H.-A. Wischmann, "A modular 31-channel SQUID system for biomagnetic measurements," IEEE Trans. Appl. Supercond., vol.3, pp. 1883-1886, 1993.
-
S. David, M. Fuchs, J. Kruger, K. -M. LUdeke, and H.-A. Wischmann, "A Modular 31-channel SQUID System for Biomagnetic Measurements," IEEE Trans. Appl. Supercond., Vol.3, Pp. 1883-1886
-
-
Dössei, O.1
-
5
-
-
0029309521
-
-
1995.
-
H. Kado, G. Uehara, H. Ogata, and H. Itozaki, "Multichannel SQUID," IEICE Trans. Electron., vol. E78-C, pp. 511-518, 1995.
-
G. Uehara, H. Ogata, and H. Itozaki, "Multichannel SQUID," IEICE Trans. Electron., Vol. E78-C, Pp. 511-518
-
-
Kado, H.1
-
6
-
-
85027118557
-
-
1981.
-
S. N. Erne, H. D. Hahlbohm, H. Scheer, and Ï. Trontelj, "The Berlin magnetically shielded room (BMSR) section B : performances," in Biomagnetism, eds. S. N. Erné et al., Berlin, New York, De Gruyter, pp. 79-87, 1981.
-
H. D. Hahlbohm, H. Scheer, and Ï. Trontelj, "The Berlin Magnetically Shielded Room (BMSR) Section B : Performances," in Biomagnetism, Eds. S. N. Erné Et Al., Berlin, New York, De Gruyter, Pp. 79-87
-
-
Erne, S.N.1
-
7
-
-
0001654776
-
-
1990.
-
D. Drung, R. Cantor, M. Peters, H.J. Scheer, and H. Koch, "Low-noise high speed dc superconducting quantum interference device magnetometer with simplified feedback electronics," Appl. Phys. Lett., vol. 57, pp. 406-408, 1990.
-
R. Cantor, M. Peters, H.J. Scheer, and H. Koch, "Low-noise High Speed Dc Superconducting Quantum Interference Device Magnetometer with Simplified Feedback Electronics," Appl. Phys. Lett., Vol. 57, Pp. 406-408
-
-
Drung, D.1
-
8
-
-
0026121480
-
-
1991.
-
H. Seppä, A. Ahonen, J. Knuutila, J. Simola, and V. Vilkman, "Dc-SQUID electronics based on adaptive positive feedback: experiments," IEEE Trans. Magn., vol. 27, pp. 2488-2490, 1991.
-
A. Ahonen, J. Knuutila, J. Simola, and V. Vilkman, "Dc-SQUID Electronics Based on Adaptive Positive Feedback: Experiments," IEEE Trans. Magn., Vol. 27, Pp. 2488-2490
-
-
Seppä, H.1
-
9
-
-
0026352787
-
-
1991.
-
P. Carolli, L. Chiaventi, R. Leoni, M. Pullaro, and G. S. Spagnolo, "A planar second-order DC SQUID gradiometer," Clin. Phys. Physiol. Meas., vol. 12, Supple. B, pp. 13-19, 1991.
-
L. Chiaventi, R. Leoni, M. Pullaro, and G. S. Spagnolo, "A Planar Second-order DC SQUID Gradiometer," Clin. Phys. Physiol. Meas., Vol. 12, Supple. B, Pp. 13-19
-
-
Carolli, P.1
-
10
-
-
0028429252
-
-
1994.
-
D. Drung and H. Koch, "An integrated dc SQUID magnetometer with variable additional positive feed back," Supercond. Sci. Technol., vol. 7, no. 5, pp. 242-245, 1994.
-
"An Integrated Dc SQUID Magnetometer with Variable Additional Positive Feed Back," Supercond. Sci. Technol., Vol. 7, No. 5, Pp. 242-245
-
-
Drung, D.1
Koch, H.2
-
11
-
-
0026121897
-
-
vol. 27, no. 2, pp. 2793-2796, 1991.
-
H. Koch, R. Cantor, D. Drung, S. N. Erne, K. P. Matthies, M. Peters, T. Ryhänen, H. J. Scheer, and H. D. Hahlbohm, "A 37 channel dc SQUID magnetometer system," IEEE Trans. Magn., vol. 27, no. 2, pp. 2793-2796, 1991.
-
A 37 Channel Dc SQUID Magnetometer System," IEEE Trans. Magn.
-
-
Koch, H.1
Cantor, R.2
Drung, D.3
Erne, S.N.4
Matthies, K.P.5
Peters, M.6
Ryhänen, T.7
Scheer, H.J.8
Hahlbohm, H.D.9
-
12
-
-
85027158323
-
-
Berlin, pp. 5I7-520, 1992.
-
O. Dössei, B. David, M. Fuchs, J. Kruger, W. H. Kullmann, and K. M. Liideke, "A modular 19-channel SQUID system for biomagnetic measurements," in Proc. SQUID'91, Berlin, pp. 5I7-520, 1992.
-
A Modular 19-channel SQUID System for Biomagnetic Measurements," in Proc. SQUID'91
-
-
Dössei, O.1
David, B.2
Fuchs, M.3
Kruger, J.4
Kullmann, W.H.5
Liideke, K.M.6
-
13
-
-
85027152479
-
-
1991.
-
H.J. M. ter Brake, J. Flokstra, E. P. Houwman, D. Veldhuis, W. Jaszczuk, R. Stammis, G. K. van Ancum, and H. Rogalla, "On the SQUID-modules for the UT multichannel neuromagnetometer," Proc. SQUID'91, pp. 521-524, 1991.
-
J. Flokstra, E. P. Houwman, D. Veldhuis, W. Jaszczuk, R. Stammis, G. K. Van Ancum, and H. Rogalla, "On the SQUID-modules for the UT Multichannel Neuromagnetometer," Proc. SQUID'91, Pp. 521-524
-
-
Ter Brake, H.J.M.1
-
14
-
-
0027555130
-
-
1993.
-
N. Shimizu, N. Chiba, S. Yabe, T. Ishikawa, K. Chinone, and S. Kiryu, "Performance of dc SQUIDs fabricated on 4-inch silicon wafer," IEEE Trans. Appl. Supercond., vol. 3, no. 1, pp. 1828-1831, 1993.
-
N. Chiba, S. Yabe, T. Ishikawa, K. Chinone, and S. Kiryu, "Performance of Dc SQUIDs Fabricated on 4-inch Silicon Wafer," IEEE Trans. Appl. Supercond., Vol. 3, No. 1, Pp. 1828-1831
-
-
Shimizu, N.1
-
15
-
-
0027694358
-
-
1993.
-
K. Chinone, T. Ataka, and N. Shimizu, "Easy process for fabrication of high-reliability dc-SQUIDs," IEEE Trans. Magn., vol. 29, no. 6, pp. 3562-3564, 1993.
-
T. Ataka, and N. Shimizu, "Easy Process for Fabrication of High-reliability Dc-SQUIDs," IEEE Trans. Magn., Vol. 29, No. 6, Pp. 3562-3564
-
-
Chinone, K.1
-
16
-
-
0028756078
-
-
1994.
-
Y. Hirata, S. Kuriki, S. Nakayama, K. Chinone, T. Ataka, K. Ikeda, and Y. Kamioka, "Design and development of a 19-channel SQUID magnetometer system," in Proe. IEEE IMTC, Hamamatsu, pp. 1369-1371, 1994.
-
S. Kuriki, S. Nakayama, K. Chinone, T. Ataka, K. Ikeda, and Y. Kamioka, "Design and Development of a 19-channel SQUID Magnetometer System," in Proe. IEEE IMTC, Hamamatsu, Pp. 1369-1371
-
-
Hirata, Y.1
-
17
-
-
0004857261
-
-
1987.
-
S. Kuriki, M. Matsuda, and A. Naya, "Dc SQUID made of NbN/a-Si/NbN tunnel junctions," IEEE Trans. Magn., vol. MAG-23, pp. 1064-1067, 1987.
-
M. Matsuda, and A. Naya, "Dc SQUID Made of NbN/a-Si/NbN Tunnel Junctions," IEEE Trans. Magn., Vol. MAG-23, Pp. 1064-1067
-
-
Kuriki, S.1
-
18
-
-
85027165615
-
-
1991.
-
K. Okuda, H. Takeuchi, M. Mukai, S. Kuriki, Y. Uchikawa, and M. Kotani, "Designing and inspecting system of prefabricated magnetically shielded room for biomagnetism," in Abst. of 8th Int. Conf. Biomagnetism, Münster, pp. 367-368, 1991.
-
H. Takeuchi, M. Mukai, S. Kuriki, Y. Uchikawa, and M. Kotani, "Designing and Inspecting System of Prefabricated Magnetically Shielded Room for Biomagnetism," in Abst. of 8th Int. Conf. Biomagnetism, Münster, Pp. 367-368
-
-
Okuda, K.1
|