-
1
-
-
0001818020
-
SQUID Concepts and Systems
-
eds.: H. Weinstock and M. Niesenoff, NATO ASI Series, Berlin: Springer
-
J. Clarke, “SQUID Concepts and Systems”, in: Superconducting Electronics, eds.: H. Weinstock and M. Niesenoff, NATO ASI Series, vol. 59, Berlin: Springer, 1989, pp. 87–148.
-
(1989)
Superconducting Electronics
, vol.59
, pp. 87-148
-
-
Clarke, J.1
-
2
-
-
26144433413
-
SQUID Magnetometers for Low-Frequency Applications
-
Sept.
-
T. Ryhänen, H. Seppä, R. Ilmoniemi and J. Knuutila, “SQUID Magnetometers for Low-Frequency Applications”, J. Low Temp. Phys., 76, 287–386, Sept. 1989.
-
(1989)
J. Low Temp. Phys.
, vol.76
, pp. 287-386
-
-
Ryhänen, T.1
Seppä, H.2
Ilmoniemi, R.3
Knuutila, J.4
-
3
-
-
85050559763
-
SQUID Sensors
-
eds: W. Göpel, J. Hesse, J.N. Zemel, Magnetic Sensors, eds.: R. Boll, K.J. Overshott, Weinheim: VCH
-
H. Koch, “SQUID Sensors”, in: Sensors - A Comprehensive Survey, eds: W. Göpel, J. Hesse, J.N. Zemel, vol. 5, Magnetic Sensors, eds.: R. Boll, K.J. Overshott, Weinheim: VCH, 1989, 381–445.
-
(1989)
Sensors - A Comprehensive Survey
, vol.5
, pp. 381-445
-
-
Koch, H.1
-
5
-
-
36749108668
-
High Quality Refratory Josephson Tunnel Junction Utilizing Thin Aluminium Layers
-
M. Gurvitch, M.A. Washington, and H.A. Higgins, “High Quality Refratory Josephson Tunnel Junction U tilizing Thin Aluminium Layers”, Appl. Phys. Lett., 42, 472–474, 1983.
-
(1983)
Appl. Phys. Lett.
, vol.42
, pp. 472-474
-
-
Gurvitch, M.1
Washington, M.A.2
Higgins, H.A.3
-
7
-
-
0347272826
-
A Novel Modulation Technique for 1/f-Noise Reduction in dc SQUIDs
-
March
-
V. Foglietti, W.J. Gallagher, and R.H. Koch, “A Novel Modulation Technique for 1/f-Noise Reduction in dc SQUIDs,” IEEE Trans. Magn., MAG-23, 1150–1153, March 1987.
-
(1987)
IEEE Trans. Magn.
, vol.MAG-23
, pp. 1150-1153
-
-
Foglietti, V.1
Gallagher, W.J.2
Koch, R.H.3
-
8
-
-
0024628984
-
Measured Performance Parameters of Gradiometers with digital Output
-
March
-
D. Drung, E. Crocoll, R. Herwig, M. Neuhaus, and W. Jutzi, “Measured Performance Parameters of Gradiometers with digital Output,” IEEE Trans. Magn., MAG-25, 1034–1037, March 1989.
-
(1989)
IEEE Trans. Magn.
, vol.MAG-25
, pp. 1034-1037
-
-
Drung, D.1
Crocoll, E.2
Herwig, R.3
Neuhaus, M.4
Jutzi, W.5
-
9
-
-
0000999940
-
Effect of damping resistance on voltage versus flux relation of a dc SQUID with large inductance and critical current
-
March
-
K. Enpuku, K. Sueoka, K. Yoshida, and F. Irie, “Effect of damping resistance on voltage versus flux relation of a dc SQUID with large inductance and critical current”, J. Appl. Phys., 57, 1691–1697, March 1985.
-
(1985)
J. Appl. Phys.
, vol.57
, pp. 1691-1697
-
-
Enpuku, K.1
Sueoka, K.2
Yoshida, K.3
Irie, F.4
-
10
-
-
0023398943
-
Effects on dc SQUID Characteristics of Damping of Input Coil Resonances
-
August
-
J. Knuutila, A. Ahonen, and C.D. Tesche, “Effects on dc SQUID Characteristics of Damping of Input Coil Resonances”, J. Low Temp. Phys., 68, 269–284, August 1987.
-
(1987)
J. Low Temp. Phys.
, vol.68
, pp. 269-284
-
-
Knuutila, J.1
Ahonen, A.2
Tesche, C.D.3
-
11
-
-
84939367248
-
Optimization and Performance of Integrated dc SQUIDs Fabricated Using a Simplified Four-Level Process
-
this volume.
-
R. Cantor, T. Ryhänen, D. Drung, H. Koch, and H. Seppä, “Optimization and Performance of Integrated dc SQUIDs Fabricated Using a Simplified Four-Level Process”, this volume.
-
-
-
Cantor, R.1
Ryhänen, T.2
Drung, D.3
Koch, H.4
Seppä, H.5
-
12
-
-
0010646123
-
Characterization of Brain Noise Using a High Sensitivity 7-Channel Magnetometer
-
eds.: K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S.J. Williamson, Tokyo Denki University Press, Tokyo
-
J. Knuutila and M.S. Hämäläinen, “Characterization of Brain Noise Using a High Sensitivity 7-Channel Magnetometer”, in: Biomagnetism’87, eds.: K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S.J. Williamson, Tokyo Denki University Press, Tokyo, pp. 186–189, 1988.
-
(1988)
Biomagnetism’87
, pp. 186-189
-
-
Knuutila, J.1
Hämäläinen, M.S.2
-
13
-
-
0001654776
-
Low-noise high-speed dc superconducting quantum interference device magnetometer with simplified feedback electronics
-
July
-
D. Drung, R. Cantor, M. Peters, H.J. Scheer, and H. Koch, “Low-noise high-speed dc superconducting quantum interference device magnetometer with simplified feedback electronics”, Appl. Phys. Lett., 57, 406–408, July 1990.
-
(1990)
Appl. Phys. Lett.
, vol.57
, pp. 406-408
-
-
Drung, D.1
Cantor, R.2
Peters, M.3
Scheer, H.J.4
Koch, H.5
-
14
-
-
84916169089
-
A dc SQUID Magnetometer with Nb-SixNy-Nb Junctions
-
Tokyo: Japanese Society of Applied Physics, June
-
R. Cantor, D. Drung, M. Peters, H.J. Scheer, and H. Koch, “A dc SQUID Magnetometer with Nb-Si x N y -Nb Junctions”, in: Extented Abstracts of 1989 International Superconductivity Electronics Conference ISEC’89, Tokyo: Japanese Society of Applied Physics, pp. 63–65, June 1989.
-
(1989)
Extented Abstracts of 1989 International Superconductivity Electronics Conference ISEC’89
, pp. 63-65
-
-
Cantor, R.1
Drung, D.2
Peters, M.3
Scheer, H.J.4
Koch, H.5
-
15
-
-
33748626150
-
Integrated dc SQUID Magnetometer with Simplified Read-out
-
March
-
R. Cantor, D. Drung, M. Peters, HJ. Scheer, and H. Koch, “Integrated dc SQUID Magnetometer with Simplified Read-out”, Supercond. Sci. Technol., 3, 108–112, March 1990.
-
(1990)
Supercond. Sci. Technol.
, vol.3
, pp. 108-112
-
-
Cantor, R.1
Drung, D.2
Peters, M.3
Scheer, H.J.4
Koch, H.5
-
16
-
-
84939360662
-
2-Channel DC-SQUID Magnetometer System for Biomagnetic magnetic Application
-
eds.: K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S.J. Williamson, Tokyo Denki University Press, Tokyo
-
M. Nakanishi, M. Koyanagi, H. Kado, N. Kasai, and T. Endo, “2-Channel DC-SQUID Magnetometer System for Biomagnetic magnetic Application”, in: Biomagnetism’87, eds.: K. Atsumi, M. Kotani, S. Ueno, T. Katila, and S.J. Williamson, Tokyo Denki University Press, Tokyo, pp. 446–449, 1988.
-
(1988)
Biomagnetism’87
, pp. 446-449
-
-
Nakanishi, M.1
Koyanagi, M.2
Kado, H.3
Kasai, N.4
Endo, T.5
-
17
-
-
0015145158
-
Sensitivity Enhancement of Superconducting Quantum Interference Devices through the Use of Fractional-Turn Loops
-
Oct.
-
J.E. Zimmerman, “Sensitivity Enhancement of Superconducting Quantum Interference Devices through the Use of Fractional-Turn Loops”, J. Appl. Phys., 42, 4483–4487, Oct. 1971.
-
(1971)
J. Appl. Phys.
, vol.42
, pp. 4483-4487
-
-
Zimmerman, J.E.1
-
18
-
-
36549103723
-
Plasma nitridation process for the fabrication of all-refractory Josephson junctions
-
March
-
R. Cantor, D. Drung, M. Peters, and H. Koch, “Plasma nitridation process for the fabrication of all-refractory Josephson junctions”, J. Appl. Phys., 67, 3038–3042, March 1990.
-
(1990)
J. Appl. Phys.
, vol.67
, pp. 3038-3042
-
-
Cantor, R.1
Drung, D.2
Peters, M.3
Koch, H.4
-
19
-
-
84939369051
-
Integrated dc SQUID Magnetometer with High dV/dB
-
this volume.
-
D. Drung, R. Cantor, M. Peters, T. Ryhänen and H. Koch, “Integrated dc SQUID Magnetometer with High dV/dB”, this volume.
-
-
-
Drung, D.1
Cantor, R.2
Peters, M.3
Ryhänen, T.4
Koch, H.5
-
20
-
-
0002470275
-
The Berlin magnetically shielded room (BMSR). Section B - Performances
-
eds.: S.N. Erné, H.D. Hahlbohm, and H. Lübbig, de Gruyter, Berlin
-
S.N. Erné H.D. Hahlbohm, H. Scheer, and Z. Trontelj, “The Berlin magnetically shielded room (BMSR). Section B - Performances”, in: Biomagnetism, eds.: S.N. Erné, H.D. Hahlbohm, and H. Lübbig, de Gruyter, Berlin, pp. 79–87, 1981.
-
(1981)
Biomagnetism
, pp. 79-87
-
-
Erné, S.N.1
Hahlbohm, H.D.2
Scheer, H.3
Trontelj, Z.4
-
21
-
-
84939371155
-
-
patent pending.
-
S.N. Erné, patent pending.
-
-
-
Erné, S.N.1
|