메뉴 건너뛰기




Volumn 9, Issue 6, 1996, Pages 499-504

Cerebral monitoring

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA; BLOOD OXYGEN TENSION; BRAIN BLOOD FLOW; BRAIN FUNCTION; BRAIN METABOLISM; BRAIN PERFUSION; DIAGNOSTIC VALUE; DOPPLER FLOWMETRY; ELECTROENCEPHALOGRAM; EVOKED RESPONSE; FUNCTIONAL ASSESSMENT; HUMAN; INFRARED SPECTROSCOPY; INTENSIVE CARE; INTRACRANIAL PRESSURE; JUGULAR VEIN; OXIMETRY; PATIENT MONITORING; PRIORITY JOURNAL; SHORT SURVEY;

EID: 0029838275     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/00001503-199612000-00010     Document Type: Short Survey
Times cited : (3)

References (74)
  • 1
    • 0029092364 scopus 로고
    • Intracranial pressure and cerebral perfusion pressure in severe head injury
    • Lang EW, Chesnut RM: Intracranial pressure and cerebral perfusion pressure in severe head injury. New Horizons 1995, 3:400-409.
    • (1995) New Horizons , vol.3 , pp. 400-409
    • Lang, E.W.1    Chesnut, R.M.2
  • 2
    • 0029560419 scopus 로고
    • Cerebral perfusion pressure: Management protocol and clinical results
    • Rosner MJ, Rosner SD, Johnson AH: Cerebral perfusion pressure: management protocol and clinical results. J Neurosurg 1995, 83:949-962. An outstanding report (large clinical implications) on CPP management as primary end-point of severe head injury management. In this study, volume expansion, cerebral spinal fluid drainage, systemic vasopressors and mannitol, used to maintain a minimum CPP of at least 70mmHg, resulted in a significantly better outcome.
    • (1995) J Neurosurg , vol.83 , pp. 949-962
    • Rosner, M.J.1    Rosner, S.D.2    Johnson, A.H.3
  • 3
    • 0029125505 scopus 로고
    • Intracranial pressure monitoring techniques
    • Ghajar J: Intracranial pressure monitoring techniques. New Horizons 1995, 3:395-399.
    • (1995) New Horizons , vol.3 , pp. 395-399
    • Ghajar, J.1
  • 4
    • 0028905591 scopus 로고
    • Survey of critical care management of comatose head-injured patients in the United States
    • Ghajar J, Hariri RJ, Narayan RK, Iacono LA, Firlik K, Patterson RH: Survey of critical care management of comatose head-injured patients in the United States. Crit Care Med 1995, 23:560-567. An interesting survey report revealing more than ever the considerable variation in the current management of severe head injury.
    • (1995) Crit Care Med , vol.23 , pp. 560-567
    • Ghajar, J.1    Hariri, R.J.2    Narayan, R.K.3    Iacono, L.A.4    Firlik, K.5    Patterson, R.H.6
  • 5
    • 0029092362 scopus 로고
    • Cerebral blood flow in severe clinical head injury
    • Bouma GJ, Muizelaar JP: Cerebral blood flow in severe clinical head injury. New Horizons 1995, 3:384-394.
    • (1995) New Horizons , vol.3 , pp. 384-394
    • Bouma, G.J.1    Muizelaar, J.P.2
  • 6
    • 0029143398 scopus 로고
    • Transcranial Doppler measurements
    • Newel DW: Transcranial Doppler measurements. New Horizons 1995, 3:423-430.
    • (1995) New Horizons , vol.3 , pp. 423-430
    • Newel, D.W.1
  • 7
    • 0028868969 scopus 로고
    • Potential and limitations of transcranial color-coded sonography in stroke patients
    • Seidel G, Kaps M, Gerriets T: Potential and limitations of transcranial color-coded sonography in stroke patients. Stroke 1995, 26:2061-2066.
    • (1995) Stroke , vol.26 , pp. 2061-2066
    • Seidel, G.1    Kaps, M.2    Gerriets, T.3
  • 8
    • 0028807511 scopus 로고
    • Transcranial Doppler ultrasonography: What is its role in cardiac and vascular surgical patients?
    • Kahn RA, Slogoff FB, Reich DL, Konstadt SN: Transcranial Doppler ultrasonography: what is its role in cardiac and vascular surgical patients? J Cardiothor Vasc Anesth 1995, 9:589-597. A good review paper on the technical aspects and the clinical utility of TCD in cardiac and vascular surgical patients.
    • (1995) J Cardiothor Vasc Anesth , vol.9 , pp. 589-597
    • Kahn, R.A.1    Slogoff, F.B.2    Reich, D.L.3    Konstadt, S.N.4
  • 9
    • 0028906720 scopus 로고
    • Cerebrovascular carbon dioxide reactivity in carotid artery disease: Relation to intraoperative cerebral monitoring results in 100 carotid endarterectomies
    • Thiel A, Zickmann B, Stertmann WA, Wyderka T, Hempelman G: Cerebrovascular carbon dioxide reactivity in carotid artery disease: relation to intraoperative cerebral monitoring results in 100 carotid endarterectomies. Anesthesiology 1995, 52:655-661.
    • (1995) Anesthesiology , vol.52 , pp. 655-661
    • Thiel, A.1    Zickmann, B.2    Stertmann, W.A.3    Wyderka, T.4    Hempelman, G.5
  • 11
    • 0029027644 scopus 로고
    • The effect of acute hypocapnia on middle cerebral artery transcranial Doppler velocity during orthotopic liver transplantation: Changes at reperfusion
    • Doblar DD, Lim YC, Frenette L, Poplawski S, Ranjan D, Ronderos J: The effect of acute hypocapnia on middle cerebral artery transcranial Doppler velocity during orthotopic liver transplantation: changes at reperfusion. Anesth Analg 1995, 80:1194-1198.
    • (1995) Anesth Analg , vol.80 , pp. 1194-1198
    • Doblar, D.D.1    Lim, Y.C.2    Frenette, L.3    Poplawski, S.4    Ranjan, D.5    Ronderos, J.6
  • 12
    • 0028887478 scopus 로고
    • Noninvasive monitoring of cerebral perfusion by transcranial Doppler during fulminant hepatic failure and liver transplantation
    • Sidi A, Mahla M: Noninvasive monitoring of cerebral perfusion by transcranial Doppler during fulminant hepatic failure and liver transplantation. Anesth Analg 1995, 80:194-200.
    • (1995) Anesth Analg , vol.80 , pp. 194-200
    • Sidi, A.1    Mahla, M.2
  • 13
    • 0030070981 scopus 로고    scopus 로고
    • Comparison of transcranial Doppler ultrasonography and transesophageal echocardiography to monitor emboli during coronary artery bypass surgery
    • Barbut D, Yao FS, Hager DN, Kavanaugh P, Trifiletti RR, Gold JP: Comparison of transcranial Doppler ultrasonography and transesophageal echocardiography to monitor emboli during coronary artery bypass surgery. Stroke 1996, 27:87-90.
    • (1996) Stroke , vol.27 , pp. 87-90
    • Barbut, D.1    Yao, F.S.2    Hager, D.N.3    Kavanaugh, P.4    Trifiletti, R.R.5    Gold, J.P.6
  • 14
    • 0028874037 scopus 로고
    • Detection of cerebral microemboli by means of transcranial Doppler monitoring before and after carotid endarterectomy
    • Van Zuilen EV, Moll FL, Vermeulen FE, Mauser HW, Van Gijn J, Ackerstaff RG: Detection of cerebral microemboli by means of transcranial Doppler monitoring before and after carotid endarterectomy. Stroke 1995, 26:210-213.
    • (1995) Stroke , vol.26 , pp. 210-213
    • Van Zuilen, E.V.1    Moll, F.L.2    Vermeulen, F.E.3    Mauser, H.W.4    Van Gijn, J.5    Ackerstaff, R.G.6
  • 15
    • 0028812675 scopus 로고
    • Occurrence of transcranial Doppler high-intensity transient signals in patients with potential cardiac sources of embolism. A prospective study
    • Sliwka U, Job FP, Wissuwa D, Diehl RR, Flachskampf FA, Hanrath P, Noth J: Occurrence of transcranial Doppler high-intensity transient signals in patients with potential cardiac sources of embolism. A prospective study. Stroke 1995, 26:2067-2070.
    • (1995) Stroke , vol.26 , pp. 2067-2070
    • Sliwka, U.1    Job, F.P.2    Wissuwa, D.3    Diehl, R.R.4    Flachskampf, F.A.5    Hanrath, P.6    Noth, J.7
  • 16
    • 0030039382 scopus 로고    scopus 로고
    • Detection of intracranial internal carotid artery and middle cerebral artery vasospasm following subarachnoid hemorrhage
    • Burch CM, Wozniak MA, Sloan MA, Rothman MI, Rigamonti D, Permutt T, Numaguchi Y: Detection of intracranial internal carotid artery and middle cerebral artery vasospasm following subarachnoid hemorrhage. J Neuroimaging 1996, 6:8-15.
    • (1996) J Neuroimaging , vol.6 , pp. 8-15
    • Burch, C.M.1    Wozniak, M.A.2    Sloan, M.A.3    Rothman, M.I.4    Rigamonti, D.5    Permutt, T.6    Numaguchi, Y.7
  • 18
    • 0029030571 scopus 로고
    • The role of intraoperative transcranial Doppler monitoring in carotid artery surgery
    • Nedey C, Barjoud H, Chatelard P, Pizza E, Brunon AM, Adeleine P, Sabben F, Ganichot GF, Jurus C, Chatel C, Streichenberger R: The role of intraoperative transcranial Doppler monitoring in carotid artery surgery. Ann Vasc Surg 1995, 9:247-251. An interesting report on the feasibility and the clinical role of per-operative TCD in carotid artery surgery. As one-half of their patients also received continuous EEG-monitoring, they were able to make a comparison between real-time EEG and TCD recordings.
    • (1995) Ann Vasc Surg , vol.9 , pp. 247-251
    • Nedey, C.1    Barjoud, H.2    Chatelard, P.3    Pizza, E.4    Brunon, A.M.5    Adeleine, P.6    Sabben, F.7    Ganichot, G.F.8    Jurus, C.9    Chatel, C.10    Streichenberger, R.11
  • 19
    • 0028847097 scopus 로고
    • Transcranial Doppler sonography indicates critical brain perfusion during hemorrhagic hypotension in dogs
    • Werner C, Hoffman WE, Kochs E, Albrecht RF, Schulte am Esch J: Transcranial Doppler sonography indicates critical brain perfusion during hemorrhagic hypotension in dogs. Anesth Analg 1995, 81:1203-1207.
    • (1995) Anesth Analg , vol.81 , pp. 1203-1207
    • Werner, C.1    Hoffman, W.E.2    Kochs, E.3    Albrecht, R.F.4    Schulte Am Esch, J.5
  • 20
    • 0029129039 scopus 로고
    • Cerebral metabolic management
    • Robertson CS, Cormio M: Cerebral metabolic management. New Horizons 1995, 3:410-422. An excellent review (part of an excellent edition of New Horizons on 'Critical Care of Severe Head Injury'). This review explains the principles of jugular bulb oximetry in view of overall cerebral metabolism. Furthermore, therapeutic strategies are depicted to optimize cerebral metabolism, guided by jugular bulb oximetry.
    • (1995) New Horizons , vol.3 , pp. 410-422
    • Robertson, C.S.1    Cormio, M.2
  • 23
    • 0029961108 scopus 로고    scopus 로고
    • Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury
    • Souter MJ, Andrews PJ: Validation of the Edslab dual lumen oximetry catheter for continuous monitoring of jugular bulb oxygen saturation after severe head injury. Br J Anaesth 1996, 76:744-746.
    • (1996) Br J Anaesth , vol.76 , pp. 744-746
    • Souter, M.J.1    Andrews, P.J.2
  • 24
    • 0029040408 scopus 로고
    • Accuracy of continuous jugular bulb venous oximetry during intracranial surgery
    • Gunn HC, Matta BF, Lam AM, Mayberg TS: Accuracy of continuous jugular bulb venous oximetry during intracranial surgery. J Neurosurg Anesth 1995, 7:174-177.
    • (1995) J Neurosurg Anesth , vol.7 , pp. 174-177
    • Gunn, H.C.1    Matta, B.F.2    Lam, A.M.3    Mayberg, T.S.4
  • 25
    • 0028272254 scopus 로고
    • Jugular venous desaturationand outcome after head injury
    • Gopinath SP, Robertson CS, Contant CF: Jugular venous desaturation and outcome after head injury. J Neurol Neurosurg Psychiatry 1994, 57:717-723. The cornerstone of jugular bulb oximetry. The authors showed that jugular bulb desaturation was strongly associated with a poor neurological outcome. When the effect of jugular desaturation was adjusted for all other covariates which were found to be significant to outcome, including age, severity of injury, type of injury, lowest recorded CPP and highest recorded temperature, the incidence of jugular desaturation was still strongly significant to a worse neurological outcome (P=0.003).
    • (1994) J Neurol Neurosurg Psychiatry , vol.57 , pp. 717-723
    • Gopinath, S.P.1    Robertson, C.S.2    Contant, C.F.3
  • 26
    • 0029014677 scopus 로고
    • Continuous monitoring of jugular bulb oxygen saturation in comatose patients - Therapeutic implications
    • Schneider GH, Helden A, Lanksch WR, Unterberg A: Continuous monitoring of jugular bulb oxygen saturation in comatose patients - therapeutic implications. Acta Neurochir (Wien) 1995, 134:71-75.
    • (1995) Acta Neurochir (Wien) , vol.134 , pp. 71-75
    • Schneider, G.H.1    Helden, A.2    Lanksch, W.R.3    Unterberg, A.4
  • 27
    • 0029090351 scopus 로고
    • Detection of cerebral venous desaturation by continuous jugular bulb oximetry following acute neurotrauma
    • Lewis SB, Mybrugh JA, Reilly PL: Detection of cerebral venous desaturation by continuous jugular bulb oximetry following acute neurotrauma. Anesth Intensive Care 1995, 23:307-314.
    • (1995) Anesth Intensive Care , vol.23 , pp. 307-314
    • Lewis, S.B.1    Mybrugh, J.A.2    Reilly, P.L.3
  • 28
    • 0028863297 scopus 로고
    • Correlation of jugular venous oxygen saturation to spontaneous fluctuations of cerebral perfusion pressure in patients with severe head injury
    • Murr R, Schurer L: Correlation of jugular venous oxygen saturation to spontaneous fluctuations of cerebral perfusion pressure in patients with severe head injury. Neurol Research 1995, 17:329-333.
    • (1995) Neurol Research , vol.17 , pp. 329-333
    • Murr, R.1    Schurer, L.2
  • 29
    • 0029981324 scopus 로고    scopus 로고
    • Arterio-jugular differences of oxygen for bedside assessment of CO2-reactivity and autoregulation in the acute phase of severe head injury
    • Sahuquillo J, Poca MA, Ausina A, Baguene M, Garcia RM, Rubio E: Arterio-jugular differences of oxygen for bedside assessment of CO2-reactivity and autoregulation in the acute phase of severe head injury. Acta Neurochir (Wien) 1996, 138:435-444.
    • (1996) Acta Neurochir (Wien) , vol.138 , pp. 435-444
    • Sahuquillo, J.1    Poca, M.A.2    Ausina, A.3    Baguene, M.4    Garcia, R.M.5    Rubio, E.6
  • 30
    • 0028889655 scopus 로고
    • 2 during cerebral aneurysm surgery
    • 2 during cerebral aneurysm surgery. Br J Anaesth 1995, 75:527-530. A relevant report on use of jugular bulb oximetry to identify critical MAP, revealing that approximately 50% of their patients undergoing aneurysm clipping acutely after subarachnoid haemorrhage had a critical MAP below which cerebral hypoperfusion occurred.
    • (1995) Br J Anaesth , vol.75 , pp. 527-530
    • Moss, E.1    Dearden, N.M.2    Berridge, J.C.3
  • 32
    • 0029149461 scopus 로고
    • Theoretical analysis of cerebral venous blood hemoglobin oxygen saturation as an index of cerebral oxygenation during hypothermic cardiopulmonary bypass
    • 2 values observed during hypothermic cardiopulmonary bypass may indicate impaired oxygen transfer from haemoglobin to the brain and not luxury perfusion.
    • (1995) Anesthesiology , vol.83 , pp. 405-412
    • Dexter, F.1    Hindman, B.J.2
  • 33
    • 0029449699 scopus 로고
    • Near infra-red spectroscopy
    • Harris DNF: Near infra-red spectroscopy. Anaesthesia 1995, 50:1015-1016.
    • (1995) Anaesthesia , vol.50 , pp. 1015-1016
    • Harris, D.N.F.1
  • 34
    • 0028864027 scopus 로고
    • Cerebral near-infrared spectroscopy: Ready for prime time?
    • Prough DS: Cerebral near-infrared spectroscopy: ready for prime time? Crit Care Med 1995, 23:1624-1626.
    • (1995) Crit Care Med , vol.23 , pp. 1624-1626
    • Prough, D.S.1
  • 35
    • 0028784692 scopus 로고
    • Qualitative comparison of carbon dioxide-induced changes in cerebral near-infrared spectroscopy versus jugular venous oxygen saturation in adults with acute brain disease
    • Tateishi A, Maekawa T, Soejima Y, Sadmitsu D, Yamamoto M, Matsushita M, Nakashima K: Qualitative comparison of carbon dioxide-induced changes in cerebral near-infrared spectroscopy versus jugular venous oxygen saturation in adults with acute brain disease. Crit Care Med 1995, 23:1734-1738.
    • (1995) Crit Care Med , vol.23 , pp. 1734-1738
    • Tateishi, A.1    Maekawa, T.2    Soejima, Y.3    Sadmitsu, D.4    Yamamoto, M.5    Matsushita, M.6    Nakashima, K.7
  • 36
    • 0028841596 scopus 로고
    • Can cerebrovascular reactivity be measured with near-infrared spectroscopy?
    • Smielewski P, Kirkpatrick P, Minhas P, Pickard J, Czosnycka M: Can cerebrovascular reactivity be measured with near-infrared spectroscopy? Stroke 1995, 26:2285-2292.
    • (1995) Stroke , vol.26 , pp. 2285-2292
    • Smielewski, P.1    Kirkpatrick, P.2    Minhas, P.3    Pickard, J.4    Czosnycka, M.5
  • 37
    • 0029144311 scopus 로고
    • Near-infrared measurement of cerebral oxygenation. Correlation with electroencephalographic ischemia during ventricular fibrillation
    • Levy WJ, Levin S, Chance B: Near-infrared measurement of cerebral oxygenation. Correlation with electroencephalographic ischemia during ventricular fibrillation. Anesthesiology 1995, 83:738-746.
    • (1995) Anesthesiology , vol.83 , pp. 738-746
    • Levy, W.J.1    Levin, S.2    Chance, B.3
  • 38
    • 0029563270 scopus 로고
    • Cerebral oximetry: A useful monitor during carotid artery surgery
    • Duncan LA, Ruckley CV, Wildmsith JA: Cerebral oximetry: a useful monitor during carotid artery surgery. Anaesthesia 1995, 50:1041-1045.
    • (1995) Anaesthesia , vol.50 , pp. 1041-1045
    • Duncan, L.A.1    Ruckley, C.V.2    Wildmsith, J.A.3
  • 39
    • 0030070212 scopus 로고    scopus 로고
    • Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia
    • Samra S, Dorje P, Zelenock GB, Stanley JC: Cerebral oximetry in patients undergoing carotid endarterectomy under regional anesthesia. Stroke 1996, 27:49-55.
    • (1996) Stroke , vol.27 , pp. 49-55
    • Samra, S.1    Dorje, P.2    Zelenock, G.B.3    Stanley, J.C.4
  • 40
    • 0029089721 scopus 로고
    • Regional cerebral oxygenation during cardiopulmonary bypass
    • Baris RR, Israel AL, Amory DW, Benni P: Regional cerebral oxygenation during cardiopulmonary bypass. Perfusion 1995, 10:245-248.
    • (1995) Perfusion , vol.10 , pp. 245-248
    • Baris, R.R.1    Israel, A.L.2    Amory, D.W.3    Benni, P.4
  • 41
    • 84995178365 scopus 로고
    • A comparative study of two near infrared spectrophotometers for the assessment of cerebral haemodynamics
    • Colier WN, Van Haaren NJ, Oeseburg B: A comparative study of two near infrared spectrophotometers for the assessment of cerebral haemodynamics. Acta Anaesth Scand 1995, 39:101-105.
    • (1995) Acta Anaesth Scand , vol.39 , pp. 101-105
    • Colier, W.N.1    Van Haaren, N.J.2    Oeseburg, B.3
  • 42
    • 0030059050 scopus 로고    scopus 로고
    • Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo
    • Polard V, Prough DS, DeMelo E, Deyo DJ, Uchida T, Stoddart HF: Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo. Anesth Analg 1996, 82:269-277.
    • (1996) Anesth Analg , vol.82 , pp. 269-277
    • Polard, V.1    Prough, D.S.2    DeMelo, E.3    Deyo, D.J.4    Uchida, T.5    Stoddart, H.F.6
  • 43
    • 0030019817 scopus 로고    scopus 로고
    • The influence of carbon dioxide and body position on near-infrared spectroscopic assessment of cerebral hemoglobin oxygen saturation
    • Polard V, Prough DS, DeMelo E, Deyo DJ, Uchida T, Widman R: The influence of carbon dioxide and body position on near-infrared spectroscopic assessment of cerebral hemoglobin oxygen saturation. Anesth Analg 1996, 82:278-287.
    • (1996) Anesth Analg , vol.82 , pp. 278-287
    • Polard, V.1    Prough, D.S.2    DeMelo, E.3    Deyo, D.J.4    Uchida, T.5    Widman, R.6
  • 45
    • 0028952839 scopus 로고
    • An observational study of near-infrared spectroscopy during carotid endarterectomy
    • Kirkpatrick PJ, Smielewski P, Whitfield PC, Czosnyka M, Menoin D, Pickard JD: An observational study of near-infrared spectroscopy during carotid endarterectomy. J Neurosurg 1995, 82:756-763. An excellent report with accurate study design, proving that extracranial influence of NIRS recordings are minimal.
    • (1995) J Neurosurg , vol.82 , pp. 756-763
    • Kirkpatrick, P.J.1    Smielewski, P.2    Whitfield, P.C.3    Czosnyka, M.4    Menoin, D.5    Pickard, J.D.6
  • 46
    • 0029095736 scopus 로고
    • Early detection of delayed traumatic intracranial hematomas using near-infrared spectroscopy
    • Gopinath SP, Robertson CS, Contant CF, Narayan RK, Grossman RG, Chance B: Early detection of delayed traumatic intracranial hematomas using near-infrared spectroscopy. J Neurosurg 1995, 83:438-444. An important paper revealing that, despite all current deceiving reports on NIRS, one possible main indication may already be established.
    • (1995) J Neurosurg , vol.83 , pp. 438-444
    • Gopinath, S.P.1    Robertson, C.S.2    Contant, C.F.3    Narayan, R.K.4    Grossman, R.G.5    Chance, B.6
  • 47
    • 0028924077 scopus 로고
    • Neuromonitorage in anaesthesia
    • Wilden OHG, Ravussin P, Bisonnette B: Neuromonitorage in anaesthesia [in French]. Ann Fr Anesth Reanim 1995, 14:95-102. An excellent French review article reporting the essentials of commonly used cerebral monitoring techniques in anaesthesia.
    • (1995) Ann Fr Anesth Reanim , vol.14 , pp. 95-102
    • Wilden, O.H.G.1    Ravussin, P.2    Bisonnette, B.3
  • 49
    • 0028824443 scopus 로고
    • Methods for monitoring the level of sedation
    • Avramov WE, White PF: Methods for monitoring the level of sedation. Crit Care Clin 1995, 11:803-826. The authors reviewed not only the different techniques for monitoring the level of sedation but provided also an excellent overview about the technical aspects of the different techniques.
    • (1995) Crit Care Clin , vol.11 , pp. 803-826
    • Avramov, W.E.1    White, P.F.2
  • 50
    • 0029148334 scopus 로고
    • Comparison of isoflurane and desflurane anesthetic depth using suppression of the electroencephalogram in neurosurgical patients
    • Hoffman WE, Edelman G: Comparison of isoflurane and desflurane anesthetic depth using suppression of the electroencephalogram in neurosurgical patients. Anesth Analg 1995, 81:811-816.
    • (1995) Anesth Analg , vol.81 , pp. 811-816
    • Hoffman, W.E.1    Edelman, G.2
  • 54
    • 0029983237 scopus 로고    scopus 로고
    • Remifentanil versus alfentanil: Comparative pharmacokinetics and pharmacodynamics in healthy adult male volunteers
    • Egan TD, Minto CF, Hermann DJ, Barr J, Muir KT, Shafer SL: Remifentanil versus alfentanil: comparative pharmacokinetics and pharmacodynamics in healthy adult male volunteers. Anesthesiology 1996, 84:821-833.
    • (1996) Anesthesiology , vol.84 , pp. 821-833
    • Egan, T.D.1    Minto, C.F.2    Hermann, D.J.3    Barr, J.4    Muir, K.T.5    Shafer, S.L.6
  • 55
    • 0029132165 scopus 로고
    • Electroencephalographic characteristics of emergence from propofol/sufentanil total intravenous anesthesia
    • Traast HS, Kalkman CJ: Electroencephalographic characteristics of emergence from propofol/sufentanil total intravenous anesthesia. Anesth Analg 1995, 81:366-371.
    • (1995) Anesth Analg , vol.81 , pp. 366-371
    • Traast, H.S.1    Kalkman, C.J.2
  • 56
    • 0029050436 scopus 로고
    • Awareness detection during caesarean section under general anaesthesia using spectrum analysis
    • Gaitini L, Vaida S, Collins G, Somri M, Sabo E: Awareness detection during caesarean section under general anaesthesia using spectrum analysis. Can J Anaesth 1995, 42:377-381.
    • (1995) Can J Anaesth , vol.42 , pp. 377-381
    • Gaitini, L.1    Vaida, S.2    Collins, G.3    Somri, M.4    Sabo, E.5
  • 57
    • 0029927768 scopus 로고    scopus 로고
    • Semilinear canonical correlation applied to the measurement of the electro-encephalographic effects of midazolam and flumazenil reversal
    • Schnider TW, Minto CF, Fiset P, Gregg KM, Shafer SL: Semilinear canonical correlation applied to the measurement of the electro-encephalographic effects of midazolam and flumazenil reversal. Anesthesiology 1996, 84:510-519. The canonical univariate parameter, a new parameter extracted from EEG, was used to describe the drug effect of benzodiazepines and the antagonist flumazenil.
    • (1996) Anesthesiology , vol.84 , pp. 510-519
    • Schnider, T.W.1    Minto, C.F.2    Fiset, P.3    Gregg, K.M.4    Shafer, S.L.5
  • 58
    • 0029163415 scopus 로고
    • Stump pressure, electroencephalographic changes, and the contralateral carotid artery: Another look at selective shunting
    • Harada RN, Comerota AJ, Good GM, Hashemi HA, Hulihan JF: Stump pressure, electroencephalographic changes, and the contralateral carotid artery: another look at selective shunting. Am J Surg 1995, 170:45-53. A comparative study between stump pressure and 21-channel raw EEG analyses during carotid surgery.
    • (1995) Am J Surg , vol.170 , pp. 45-53
    • Harada, R.N.1    Comerota, A.J.2    Good, G.M.3    Hashemi, H.A.4    Hulihan, J.F.5
  • 59
    • 0029017626 scopus 로고
    • The reliability of quantitative electroencephalography as an indicator of cerebral ischemia
    • Adams DC, Heyer EJ, Emerson RG, Moeller JR, Spotnitz HM, Smith DH, Delphin E, Turner C: The reliability of quantitative electroencephalography as an indicator of cerebral ischemia. Anesth Analg 1995, 81:80-83. The authors used quantitative EEG to detect cerebral ischaemia and concluded that caution is warranted when using automated systems for intra-operative interpretation of EEG related to ischaemia.
    • (1995) Anesth Analg , vol.81 , pp. 80-83
    • Adams, D.C.1    Heyer, E.J.2    Emerson, R.G.3    Moeller, J.R.4    Spotnitz, H.M.5    Smith, D.H.6    Delphin, E.7    Turner, C.8
  • 60
    • 0030023299 scopus 로고    scopus 로고
    • Electroencephalogram bispectral analysis predicts the depth of midazolam induced sedation
    • Liu J, Singh H, White PF: Electroencephalogram bispectral analysis predicts the depth of midazolam induced sedation. Anesthesiology 1996, 84:64-69.
    • (1996) Anesthesiology , vol.84 , pp. 64-69
    • Liu, J.1    Singh, H.2    White, P.F.3
  • 61
    • 0028922812 scopus 로고
    • EEG bispectrum predicts movement during thiopental/isoflurane anesthesia
    • Sebel PS, Bowles SM, Saini V, Chamoun N: EEG bispectrum predicts movement during thiopental/isoflurane anesthesia. J Clin Monit 1995, 11:83-91.
    • (1995) J Clin Monit , vol.11 , pp. 83-91
    • Sebel, P.S.1    Bowles, S.M.2    Saini, V.3    Chamoun, N.4
  • 62
    • 0030031157 scopus 로고    scopus 로고
    • The bispectral index during induction of anesthesia with midazolam and propofol
    • Hoffman WE, Zsigmond E, Albrecht RF: The bispectral index during induction of anesthesia with midazolam and propofol. J Neurosurg Anesth 1996, 8:15-20.
    • (1996) J Neurosurg Anesth , vol.8 , pp. 15-20
    • Hoffman, W.E.1    Zsigmond, E.2    Albrecht, R.F.3
  • 63
    • 0028802881 scopus 로고
    • Propofol concentration and the bispectral index predicts suppression of learning during propofol/epidural anesthesia in volunteers
    • Leslie K, Sessler DI, Schroeder M, Walters K: Propofol concentration and the bispectral index predicts suppression of learning during propofol/epidural anesthesia in volunteers. Anesth Analg 1995, 81:1269-1274.
    • (1995) Anesth Analg , vol.81 , pp. 1269-1274
    • Leslie, K.1    Sessler, D.I.2    Schroeder, M.3    Walters, K.4
  • 64
    • 0030021080 scopus 로고    scopus 로고
    • Measuring the performance of anesthetic depth indicators
    • Smith WD, Dutton RC, Smith NT: Measuring the performance of anesthetic depth indicators. Anesthesiology 1996, 84:38-51 Prediction probability is an appropriate measure for evaluating and comparing the performance of different anaesthetic depth predictors, with bispectral analysis as the best predictor.
    • (1996) Anesthesiology , vol.84 , pp. 38-51
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 66
    • 0029089804 scopus 로고
    • Electrophysiologic monitoring in head injury
    • Sloan TB: Electrophysiologic monitoring in head injury. New Horizons 1995, 3:431-438.
    • (1995) New Horizons , vol.3 , pp. 431-438
    • Sloan, T.B.1
  • 67
    • 0028914054 scopus 로고
    • Mid-latency auditory evoked potentials and wakefulness during caesarean section
    • Schwender D, Madler C, Klasing S, Poppel E, Peter K: Mid-latency auditory evoked potentials and wakefulness during caesarean section. Eur J Anaesth 1995, 12:171-179.
    • (1995) Eur J Anaesth , vol.12 , pp. 171-179
    • Schwender, D.1    Madler, C.2    Klasing, S.3    Poppel, E.4    Peter, K.5
  • 69
    • 0029119651 scopus 로고
    • The effects of anesthesia with increasing end-expiratory concentrations of sevoflurane on midlatency auditory evoked potentials
    • Schwender D, Conzen P, Klasing S, Finsterer U, Poppel E, Klaus P: The effects of anesthesia with increasing end-expiratory concentrations of sevoflurane on midlatency auditory evoked potentials. Anesth Analg 1995, 81:817-822.
    • (1995) Anesth Analg , vol.81 , pp. 817-822
    • Schwender, D.1    Conzen, P.2    Klasing, S.3    Finsterer, U.4    Poppel, E.5    Klaus, P.6
  • 70
    • 0028933838 scopus 로고
    • Effects of sevoflurane on the middle latency auditory evoked response and the electroencephalographic power spectrum
    • Tatsumi K, Hiari K, Furuya H, Okuda T: Effects of sevoflurane on the middle latency auditory evoked response and the electroencephalographic power spectrum. Anesth Analg 1995, 80:940-943.
    • (1995) Anesth Analg , vol.80 , pp. 940-943
    • Tatsumi, K.1    Hiari, K.2    Furuya, H.3    Okuda, T.4
  • 71
    • 0028882093 scopus 로고
    • The auditory evoked potential and paediatric anaesthesia
    • O'Kelly SW, Smith DC, Pilkington SN: The auditory evoked potential and paediatric anaesthesia. Br J Anaesth 1995, 75:428-430.
    • (1995) Br J Anaesth , vol.75 , pp. 428-430
    • O'Kelly, S.W.1    Smith, D.C.2    Pilkington, S.N.3
  • 72
    • 0029012270 scopus 로고
    • Electrophysiological monitoring for selective shunting during carotid endarterectomy
    • Fiori L, Parenti G: Electrophysiological monitoring for selective shunting during carotid endarterectomy. J Neurosurg Anesth 1995, 7:168-173.
    • (1995) J Neurosurg Anesth , vol.7 , pp. 168-173
    • Fiori, L.1    Parenti, G.2
  • 73
    • 0029085067 scopus 로고
    • Neuromonitoring during hypothermic cardiopulmonary bypass
    • Gombotz H: Neuromonitoring during hypothermic cardiopulmonary bypass. J Neurosurg Anesth 1995, 7:289-296.
    • (1995) J Neurosurg Anesth , vol.7 , pp. 289-296
    • Gombotz, H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.