1
-
-
0000320482
-
Oximeter, an instrument for measuring continuously the oxygen saturation of arterial blood in man
-
Millikan GA. Oximeter, an instrument for measuring continuously the oxygen saturation of arterial blood in man. Rev Sci Instrum 1942;13:434-4.
-
(1942)
Rev Sci Instrum
, vol.13
, pp. 434-434
-
-
Millikan, G.A.1
-
2
-
-
0018924654
-
Spectrophotometric monitoring of arterial oxygen saturation in the fingertip
-
Yoshiya I, Shimada Y, Tanaka K. Spectrophotometric monitoring of arterial oxygen saturation in the fingertip. Med Biol Eng Comput 1980;18:27-32.
-
(1980)
Med Biol Eng Comput
, vol.18
, pp. 27-32
-
-
Yoshiya, I.1
Shimada, Y.2
Tanaka, K.3
-
3
-
-
0017571334
-
Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters
-
Jöbsis FF, Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science 1977;198:1264-7.
-
(1977)
Science
, vol.198
, pp. 1264-1267
-
-
Jöbsis, F.F.1
-
4
-
-
84975647283
-
Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties
-
Patterson MS, Chance B, Wilson BC. Time resolved reflectance and transmittance for the non-invasive measurement of tissue optical properties. Appl Optics 1989;28:2331-6.
-
(1989)
Appl Optics
, vol.28
, pp. 2331-2336
-
-
Patterson, M.S.1
Chance, B.2
Wilson, B.C.3
-
5
-
-
0023281071
-
Optical properties of human brain tissue, meninges and brain tumors in the spectral range of 200 to 900 run
-
Eggert HR, Blazek V. Optical properties of human brain tissue, meninges and brain tumors in the spectral range of 200 to 900 run. Neurosurgery 1987;21:459-64.
-
(1987)
Neurosurgery
, vol.21
, pp. 459-464
-
-
Eggert, H.R.1
Blazek, V.2
-
6
-
-
0024042308
-
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain
-
Chance B, Leigh JS, Miyake H, et al. Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain. Proc Natl Acad Sci USA 1988;85:4971-5.
-
(1988)
Proc Natl Acad Sci USA
, vol.85
, pp. 4971-4975
-
-
Chance, B.1
Leigh, J.S.2
Miyake, H.3
-
7
-
-
0023069288
-
Simulation of the point spread function for light in tissue by a Monte Carlo method
-
van der Zee P, Delpy DT. Simulation of the point spread function for light in tissue by a Monte Carlo method. Adv Exp Med Biol 1987;215:179-91.
-
(1987)
Adv Exp Med Biol
, vol.215
, pp. 179-191
-
-
Van der Zee, P.1
Delpy, D.T.2
-
8
-
-
0025756838
-
Measurement of regional cerebrovascular haemoglobin oxygen saturation in cats using optical spectroscopy
-
McCormick PW, Stewart M, Ray P, et al. Measurement of regional cerebrovascular haemoglobin oxygen saturation in cats using optical spectroscopy. Neurol Res 1991;13:65-70.
-
(1991)
Neurol Res
, vol.13
, pp. 65-70
-
-
McCormick, P.W.1
Stewart, M.2
Ray, P.3
-
9
-
-
0020351656
-
Rat brain monitoring by near-infrared spectroscopy: An assessment of possible clinical significance
-
Giannini I, Ferrari M, Carpi A, Fasella P. Rat brain monitoring by near-infrared spectroscopy: an assessment of possible clinical significance. Physiol Chem Phys 1982;14:295-305.
-
(1982)
Physiol Chem Phys
, vol.14
, pp. 295-305
-
-
Giannini, I.1
Ferrari, M.2
Carpi, A.3
Fasella, P.4
-
10
-
-
0022962664
-
Cerebral blood volume and hemoglobin oxygen saturation monitoring in neonatal brain by near IR spectroscopy
-
Ferrari M, De Marchis C, Giannini I, et al. Cerebral blood volume and hemoglobin oxygen saturation monitoring in neonatal brain by near IR spectroscopy. Adv Exp Med Biol 1986; 200:203-11.
-
(1986)
Adv Exp Med Biol
, vol.200
, pp. 203-211
-
-
Ferrari, M.1
De Marchis, C.2
Giannini, I.3
-
11
-
-
0025817318
-
Response of cerebral blood volume to changes in arterial carbon dioxide tension in preterm and term infants
-
Wyatt JS, Edwards AD, Cope M, et al. Response of cerebral blood volume to changes in arterial carbon dioxide tension in preterm and term infants. Pediatr Res 1991;29:553-7.
-
(1991)
Pediatr Res
, vol.29
, pp. 553-557
-
-
Wyatt, J.S.1
Edwards, A.D.2
Cope, M.3
-
12
-
-
0023019602
-
Quantification of cerebral oxygenation and haemodynamics in sick newborn infants by near infrared spectroscopy
-
Wyatt JS, Cope M, Delpy DT, et al. Quantification of cerebral oxygenation and haemodynamics in sick newborn infants by near infrared spectroscopy. Lancet 1986;2:1063-6.
-
(1986)
Lancet
, vol.2
, pp. 1063-1066
-
-
Wyatt, J.S.1
Cope, M.2
Delpy, D.T.3
-
13
-
-
0022330765
-
Monitoring cerebral oxygen sufficiency in anesthesia and surgery
-
Fox E, Jöbsis-Vandervliet FF, Mitnick MH. Monitoring cerebral oxygen sufficiency in anesthesia and surgery. Adv Exp Med Biol 1985;191:849-54.
-
(1985)
Adv Exp Med Biol
, vol.191
, pp. 849-854
-
-
Fox, E.1
Jöbsis-Vandervliet, F.F.2
Mitnick, M.H.3
-
14
-
-
0027382292
-
Cerebral oxygen metabolism during hypothermic circulatory arrest in humans
-
Ausman JI, McCormick PW, Stewart M, et al. Cerebral oxygen metabolism during hypothermic circulatory arrest in humans. J Neurosurg 1993;79:810-5.
-
(1993)
J Neurosurg
, vol.79
, pp. 810-815
-
-
Ausman, J.I.1
McCormick, P.W.2
Stewart, M.3
-
15
-
-
0025365380
-
Reperfusion hyperoxia hi brain after circulatory arrest in humans
-
Smith DS, Levy W, Maris M, Chance B. Reperfusion hyperoxia hi brain after circulatory arrest in humans. Anesthesiology 1990; 73:12-9.
-
(1990)
Anesthesiology
, vol.73
, pp. 12-19
-
-
Smith, D.S.1
Levy, W.2
Maris, M.3
Chance, B.4
-
17
-
-
1642622799
-
Generation and validation of an algorithm for brain oxygen monitoring
-
Pollard V, DeMelo E, Deyo DJ, et al. Generation and validation of an algorithm for brain oxygen monitoring [abstract]. Anesth Analg 1994;78:S343.
-
(1994)
Anesth Analg
, vol.78
-
-
Pollard, V.1
DeMelo, E.2
Deyo, D.J.3
-
18
-
-
0016140572
-
2 on cerebral blood volume, blood flow, and vascular mean transit time
-
2 on cerebral blood volume, blood flow, and vascular mean transit time. Stroke 1974;5:630-9.
-
(1974)
Stroke
, vol.5
, pp. 630-639
-
-
Grubb Jr., R.L.1
Raichle, M.E.2
Eichung, J.O.3
Ter-Pogossian, M.M.4
-
19
-
-
0019516159
-
Regulation of the cerebral circulation
-
Kontos HA. Regulation of the cerebral circulation. Annu Rev Physiol 1981;43:397-407.
-
(1981)
Annu Rev Physiol
, vol.43
, pp. 397-407
-
-
Kontos, H.A.1
-
20
-
-
0026093229
-
Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics
-
McCormick PW, Stewart M, Goetting M, et al. Noninvasive cerebral optical spectroscopy for monitoring cerebral oxygen delivery and hemodynamics. Crit Care Med 1991;19:89-97.
-
(1991)
Crit Care Med
, vol.19
, pp. 89-97
-
-
McCormick, P.W.1
Stewart, M.2
Goetting, M.3
-
21
-
-
0023865632
-
Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation
-
Wray S, Cope M, Delpy DT, et al. Characterization of the near infrared absorption spectra of cytochrome aa3 and haemoglobin for the non-invasive monitoring of cerebral oxygenation. Biochem Biophys Acta 1988;933:184-92.
-
(1988)
Biochem Biophys Acta
, vol.933
, pp. 184-192
-
-
Wray, S.1
Cope, M.2
Delpy, D.T.3
-
22
-
-
84975609463
-
The influence of path length on remote optical sensing properties of biological tissue
-
Nossal R, Bonner RF, Weiss GH. The influence of path length on remote optical sensing properties of biological tissue. Appl Optics 1989;28:2238-44.
-
(1989)
Appl Optics
, vol.28
, pp. 2238-2244
-
-
Nossal, R.1
Bonner, R.F.2
Weiss, G.H.3
-
24
-
-
0030059050
-
Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo
-
Pollard V, Prough DS, DeMelo AE, et al. Validation in volunteers of a near-infrared spectroscope for monitoring brain oxygenation in vivo. Anesth Analg 1996;82:269-77.
-
(1996)
Anesth Analg
, vol.82
, pp. 269-277
-
-
Pollard, V.1
Prough, D.S.2
DeMelo, A.E.3
-
25
-
-
0025883927
-
Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans
-
McCormick PW, Stewart M, Goetting MG, Balakrishnan G. Regional cerebrovascular oxygen saturation measured by optical spectroscopy in humans. Stroke 1991;22:596-602.
-
(1991)
Stroke
, vol.22
, pp. 596-602
-
-
McCormick, P.W.1
Stewart, M.2
Goetting, M.G.3
Balakrishnan, G.4
-
26
-
-
0027992411
-
Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation
-
Olsen KS, Madsen PL, Borme T, Schmidt JF. Evaluation of a 7.5 French pulmonary catheter for continuous monitoring of cerebral venous oxygen saturation. J Neurosurg Anesth 1994;6: 233-8.
-
(1994)
J Neurosurg Anesth
, vol.6
, pp. 233-238
-
-
Olsen, K.S.1
Madsen, P.L.2
Borme, T.3
Schmidt, J.F.4
-
28
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
29
-
-
0027182950
-
Near infrared spectroscopy in adults. Does the Invos 3100 really measure intracerebral oxygenation?
-
Harris DNF, Bailey SM. Near infrared spectroscopy in adults. Does the Invos 3100 really measure intracerebral oxygenation? Anaesthesia 1993;48:694-6.
-
(1993)
Anaesthesia
, vol.48
, pp. 694-696
-
-
Harris, D.N.F.1
Bailey, S.M.2
-
30
-
-
0001837034
-
Modulating cerebral oxygen delivery and extraction in acute traumatic coma
-
Wagner KA, ed. Boston: Butterworth
-
Cruz J, Miner ME. Modulating cerebral oxygen delivery and extraction in acute traumatic coma. In: Wagner KA, ed. Neurotrauma I. Boston: Butterworth, 1986:55-72.
-
(1986)
Neurotrauma i
, pp. 55-72
-
-
Cruz, J.1
Miner, M.E.2
-
32
-
-
9044227904
-
Cerebral vascular response to diminished arterial oxygen content and the effects of inhibition of NO synthesis
-
April 29-31, Allegheny General Hospital, Pittsburgh, PA. In press
-
vonKummer R. Cerebral vascular response to diminished arterial oxygen content and the effects of inhibition of NO synthesis [abstract]. Advances in the Clinical Aspects of Cerebral Blood Flow, April 29-31, 1994, Allegheny General Hospital, Pittsburgh, PA. In press.
-
(1994)
Advances in the Clinical Aspects of Cerebral Blood Flow
-
-
Vonkummer, R.1
-
35
-
-
0025134357
-
Cerebral oxygen availability by NIR spectroscopy during transient hypoxia in humans
-
Hampson NM, Camporesi EM, Stolp BW, et al. Cerebral oxygen availability by NIR spectroscopy during transient hypoxia in humans. J Appl Physiol 1990;69:907-13.
-
(1990)
J Appl Physiol
, vol.69
, pp. 907-913
-
-
Hampson, N.M.1
Camporesi, E.M.2
Stolp, B.W.3
-
37
-
-
0026501378
-
Intracerebral penetration of infrared light. Technical note
-
McCormick PW, Stewart M, Lewis G, et al. Intracerebral penetration of infrared light. Technical note. J Neurosurg 1992;76: 315-8.
-
(1992)
J Neurosurg
, vol.76
, pp. 315-318
-
-
McCormick, P.W.1
Stewart, M.2
Lewis, G.3
-
38
-
-
0024206831
-
Estimation of optical path length through tissue from direct time of flight measurement
-
Delpy DT, Cope M, van der Zee P, et al. Estimation of optical path length through tissue from direct time of flight measurement. Phys Med Biol 1988;33:1433-42.
-
(1988)
Phys Med Biol
, vol.33
, pp. 1433-1442
-
-
Delpy, D.T.1
Cope, M.2
Van der Zee, P.3
|