메뉴 건너뛰기




Volumn 19, Issue 6, 2004, Pages 495-498

The pneumatic tourniquet technique for endoscopic radial artery harvest

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARM; ARTERY GRAFT; ARTICLE; CLINICAL ARTICLE; CONTROLLED STUDY; CORONARY ARTERY RECANALIZATION; CUFF; DONOR; ENDOSCOPIC SURGERY; ESTHETICS; FEMALE; FOLLOW UP; HEART MUSCLE ISCHEMIA; HUMAN; INFECTION; INTERMETHOD COMPARISON; MALE; RADIAL ARTERY; SURGICAL INSTRUMENT; SURGICAL TECHNIQUE; TOURNIQUET; VASOSPASM;

EID: 9744222552     PISSN: 08860440     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.0886-0440.2004.04099.x     Document Type: Article
Times cited : (9)

References (16)
  • 1
    • 0032746937 scopus 로고    scopus 로고
    • A randomized trial of endoscopic versus open saphenous vein harvest in coronary bypass surgery
    • Puskas JD, Wright CE, Miller PK, et al: A randomized trial of endoscopic versus open saphenous vein harvest in coronary bypass surgery. Ann Thorac Surg 1999;68:1509-1512.
    • (1999) Ann Thorac Surg , vol.68 , pp. 1509-1512
    • Puskas, J.D.1    Wright, C.E.2    Miller, P.K.3
  • 2
    • 0031843481 scopus 로고    scopus 로고
    • Endoscopic vein harvest for coronary artery bypass grafting: Techniques and outcomes
    • Davis Z, Jacobs HK, Zhang M, et al: Endoscopic vein harvest for coronary artery bypass grafting: Techniques and outcomes. J Thorac Cardiovasc Surg 1998;116(2):228-235.
    • (1998) J Thorac Cardiovasc Surg , vol.116 , Issue.2 , pp. 228-235
    • Davis, Z.1    Jacobs, H.K.2    Zhang, M.3
  • 3
    • 0033495221 scopus 로고    scopus 로고
    • Endoscopic saphenous vein harvest decreases leg wound complication in coronary artery bypass grafting patients
    • Kan CD, Luo CY, Yang YJ: Endoscopic saphenous vein harvest decreases leg wound complication in coronary artery bypass grafting patients. J Card Surg 1999;14(3):157-162.
    • (1999) J Card Surg , vol.14 , Issue.3 , pp. 157-162
    • Kan, C.D.1    Luo, C.Y.2    Yang, Y.J.3
  • 4
    • 0001372089 scopus 로고    scopus 로고
    • Intercellular and vascular cell adhesion molecule levels in endoscopic and open saphenous vein harvesting for coronary artery bypass surgery
    • Alrawi SJ, Samee M, Raju R, et al: Intercellular and vascular cell adhesion molecule levels in endoscopic and open saphenous vein harvesting for coronary artery bypass surgery. Heart Surg Forum 2000;3(3):241-245.
    • (2000) Heart Surg Forum , vol.3 , Issue.3 , pp. 241-245
    • Alrawi, S.J.1    Samee, M.2    Raju, R.3
  • 5
    • 0034088978 scopus 로고    scopus 로고
    • Endoscopic and traditional saphenous vein harvest: A histologic comparison
    • Griffith GL, Allen KB, Waller BF, et al: Endoscopic and traditional saphenous vein harvest: A histologic comparison. Ann Thorac Surg 2000;69(2):520-523.
    • (2000) Ann Thorac Surg , vol.69 , Issue.2 , pp. 520-523
    • Griffith, G.L.1    Allen, K.B.2    Waller, B.F.3
  • 6
    • 0035046669 scopus 로고    scopus 로고
    • Should we use video-assisted endoscopic vein harvesting as a standard technique?
    • Rodrigus IE, Stockman B, Amsel BJ, et al: Should we use video-assisted endoscopic vein harvesting as a standard technique? Heart Surg Forum 2001;4(1):53-55.
    • (2001) Heart Surg Forum , vol.4 , Issue.1 , pp. 53-55
    • Rodrigus, I.E.1    Stockman, B.2    Amsel, B.J.3
  • 7
    • 0033401438 scopus 로고    scopus 로고
    • Endoscopic verses open saphenous vein harvest: The effect on post-operative outcomes
    • Hayward TZ, Hey LA, Newman LL, et al: Endoscopic verses open saphenous vein harvest: The effect on post-operative outcomes. Ann Thorac Surg 1999;68:2107-2111.
    • (1999) Ann Thorac Surg , vol.68 , pp. 2107-2111
    • Hayward, T.Z.1    Hey, L.A.2    Newman, L.L.3
  • 8
    • 0026480558 scopus 로고
    • Revival of the radial artery for coronary artery bypass grafting
    • Acar C, Jebara VA, Portoghese M, et al: Revival of the radial artery for coronary artery bypass grafting. Ann Thoracic Surg 1992;54(4):652-659.
    • (1992) Ann Thoracic Surg , vol.54 , Issue.4 , pp. 652-659
    • Acar, C.1    Jebara, V.A.2    Portoghese, M.3
  • 9
    • 0036147974 scopus 로고    scopus 로고
    • The radial artery in coronary surgery: A 5-year experience-Clinical and angiographic results
    • Tatoulis J, Royse A, Buxton B, et al: The radial artery in coronary surgery: A 5-year experience-Clinical and angiographic results. Ann Thorac Surg 2002;73:143-148.
    • (2002) Ann Thorac Surg , vol.73 , pp. 143-148
    • Tatoulis, J.1    Royse, A.2    Buxton, B.3
  • 10
    • 0032451595 scopus 로고    scopus 로고
    • Endoscopic harvesting of the radial artery as a coronary artery bypass graft
    • Terada Y, Uchida A, Fukuda I, et al: Endoscopic harvesting of the radial artery as a coronary artery bypass graft. Ann Thorac Surg 1998;66:2123-2124.
    • (1998) Ann Thorac Surg , vol.66 , pp. 2123-2124
    • Terada, Y.1    Uchida, A.2    Fukuda, I.3
  • 11
    • 0036327865 scopus 로고    scopus 로고
    • Endoscopic radial artery harvesting: Results of first 300 patients
    • Connoly MW, Torrillo LH, Stauder MJ, et al: Endoscopic radial artery harvesting: results of first 300 patients. Ann Thorac Surg 2002;74(2):502-505.
    • (2002) Ann Thorac Surg , vol.74 , Issue.2 , pp. 502-505
    • Connoly, M.W.1    Torrillo, L.H.2    Stauder, M.J.3
  • 12
    • 0034945492 scopus 로고    scopus 로고
    • Arm complications after radial artery procurement for coronary bypass operation
    • Greene MA, Malias MA: Arm complications after radial artery procurement for coronary bypass operation. Ann Thorac Surg 2001;72(1):126-128.
    • (2001) Ann Thorac Surg , vol.72 , Issue.1 , pp. 126-128
    • Greene, M.A.1    Malias, M.A.2
  • 13
    • 0032828624 scopus 로고    scopus 로고
    • Permanent nerve injury in the forearm following radial artery harvest: A report of two cases
    • Arons JA, Collins N, Arons MS: Permanent nerve injury in the forearm following radial artery harvest: A report of two cases. Ann Plast Surg 1999;43:299-301.
    • (1999) Ann Plast Surg , vol.43 , pp. 299-301
    • Arons, J.A.1    Collins, N.2    Arons, M.S.3
  • 14
    • 0019510883 scopus 로고
    • The pneumatic tourniquet: A biochemical and electrophysiological study
    • Hurst LN, Weiglein O, Brown WF, et al: The pneumatic tourniquet: A biochemical and electrophysiological study. Plast Reconstr Surg 1982;67(5):648-652.
    • (1982) Plast Reconstr Surg , vol.67 , Issue.5 , pp. 648-652
    • Hurst, L.N.1    Weiglein, O.2    Brown, W.F.3
  • 15
    • 0018961075 scopus 로고
    • Tourniquet time-How long?
    • Klenerman L. Tourniquet time-How long? Hand 1980;12(3):231-232.
    • (1980) Hand , vol.12 , Issue.3 , pp. 231-232
    • Klenerman, L.1
  • 16
    • 0028016127 scopus 로고
    • Bipolar coagulation at different energy levels: Effect on patency
    • Hood JM, Lubahn JD: Bipolar coagulation at different energy levels: Effect on patency. Microsurgery 1994;15(8):594-597.
    • (1994) Microsurgery , vol.15 , Issue.8 , pp. 594-597
    • Hood, J.M.1    Lubahn, J.D.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.