메뉴 건너뛰기




Volumn 111, Issue 12, 2004, Pages 2278-2283

Optical coherence tomography detects characteristic retinal nerve fiber layer thickness corresponding to band atrophy of the optic discs

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; AREA UNDER THE CURVE; ARTICLE; BRAIN TUMOR; CALCULATION; CLINICAL ARTICLE; FEMALE; HOMONYMOUS HEMIANOPIA; HUMAN; MALE; NERVE FIBER; OPTIC CHIASM; OPTIC DISK ANOMALY; OPTIC DISK ATROPHY; OPTICAL COHERENCE TOMOGRAPHY; PRIORITY JOURNAL; RETINA NERVE CELL; VISUAL FIELD DEFECT;

EID: 9644307902     PISSN: 01616420     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ophtha.2004.05.035     Document Type: Article
Times cited : (116)

References (30)
  • 2
    • 0025969940 scopus 로고
    • Pituitary adenomas: Automatic static perimetry and Goldmann perimetry: A comparative study of 345 visual field charts
    • M. Grochowicki, A. Vighetto, S. Berquet Pituitary adenomas: automatic static perimetry and Goldmann perimetry A comparative study of 345 visual field charts Br J Ophthalmol 75 1991 219 221
    • (1991) Br J Ophthalmol , vol.75 , pp. 219-221
    • Grochowicki, M.1    Vighetto, A.2    Berquet, S.3
  • 3
    • 0002829950 scopus 로고
    • The primate chiasm: Details of visual fiber organization studied by silver impregnation techniques
    • W.F. Hoyt, O. Luis The primate chiasm Details of visual fiber organization studied by silver impregnation techniques Arch Ophthalmol 70 1963 69 85
    • (1963) Arch Ophthalmol , vol.70 , pp. 69-85
    • Hoyt, W.F.1    Luis, O.2
  • 5
    • 0037232860 scopus 로고    scopus 로고
    • Quantitative analysis of axonal loss in band atrophy of the optic nerve using scanning laser polarimetry
    • M.L. Monteiro, F.A. Medeiros, M.R. Ostroscki Quantitative analysis of axonal loss in band atrophy of the optic nerve using scanning laser polarimetry Br J Ophthalmol 8 2003 32 37
    • (2003) Br J Ophthalmol , vol.8 , pp. 32-37
    • Monteiro, M.L.1    Medeiros, F.A.2    Ostroscki, M.R.3
  • 6
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • D. Huang, E.A. Swanson, C.P. Lin Optical coherence tomography Science 54 1991 1178 1181
    • (1991) Science , vol.54 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 7
    • 0028914826 scopus 로고
    • Optical coherence tomography: A new tool for glaucoma diagnosis
    • J.S. Schuman, M.R. Hee, A.V. Arya Optical coherence tomography: a new tool for glaucoma diagnosis Curr Opin Ophthalmol 6 1995 89 95
    • (1995) Curr Opin Ophthalmol , vol.6 , pp. 89-95
    • Schuman, J.S.1    Hee, M.R.2    Arya, A.V.3
  • 8
    • 0029851416 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    • J.S. Schuman, T. Pedut-Kloizman, E. Hertzmark Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography Ophthalmology 103 1996 1889 1898
    • (1996) Ophthalmology , vol.103 , pp. 1889-1898
    • Schuman, J.S.1    Pedut-Kloizman, T.2    Hertzmark, E.3
  • 9
    • 0033653784 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
    • E.Z. Blumenthal, J.M. Williams, R.N. Weinreb Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography Ophthalmology 107 2000 2278 2282
    • (2000) Ophthalmology , vol.107 , pp. 2278-2282
    • Blumenthal, E.Z.1    Williams, J.M.2    Weinreb, R.N.3
  • 10
    • 0037228533 scopus 로고    scopus 로고
    • Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes
    • P. Carpineto, M. Ciancaglini, E. Zuppardi Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes Ophthalmology 110 2003 190 195
    • (2003) Ophthalmology , vol.110 , pp. 190-195
    • Carpineto, P.1    Ciancaglini, M.2    Zuppardi, E.3
  • 11
    • 0037375923 scopus 로고    scopus 로고
    • Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography
    • A. Kanamori, M. Nakamura, M.F. Escano Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography Am J Ophthalmol 135 2003 513 520
    • (2003) Am J Ophthalmol , vol.135 , pp. 513-520
    • Kanamori, A.1    Nakamura, M.2    Escano, M.F.3
  • 12
    • 0033986066 scopus 로고    scopus 로고
    • The retinal nerve fiber layer thickness in ocular hypertensive, normal, and glaucomatous eyes with optical coherence tomography
    • C. Bowd, R.N. Weinreb, J.M. Williams, L.M. Zangwill The retinal nerve fiber layer thickness in ocular hypertensive, normal, and glaucomatous eyes with optical coherence tomography Arch Ophthalmol 118 2000 22 26
    • (2000) Arch Ophthalmol , vol.118 , pp. 22-26
    • Bowd, C.1    Weinreb, R.N.2    Williams, J.M.3    Zangwill, L.M.4
  • 13
    • 0036143054 scopus 로고    scopus 로고
    • Retinal nerve fiber layer analysis: Relationship between optical coherence tomography and red-free photography
    • M.A. Soliman, T.J. Van Den Berg, A.A. Ismaeil Retinal nerve fiber layer analysis relationship between optical coherence tomography and red-free photography Am J Ophthalmol 133 2002 187 195
    • (2002) Am J Ophthalmol , vol.133 , pp. 187-195
    • Soliman, M.A.1    Van Den Berg, T.J.2    Ismaeil, A.A.3
  • 14
    • 0033761768 scopus 로고    scopus 로고
    • A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma
    • L.M. Zangwill, J. Williams, C.C. Berry A comparison of optical coherence tomography and retinal nerve fiber layer photography for detection of nerve fiber layer damage in glaucoma Ophthalmology 107 2000 1309 1315
    • (2000) Ophthalmology , vol.107 , pp. 1309-1315
    • Zangwill, L.M.1    Williams, J.2    Berry, C.C.3
  • 15
    • 0343048393 scopus 로고    scopus 로고
    • Optical coherence tomography and scanning laser polarimetry in normal, ocular hypertensive, and glaucomatous eyes
    • S.T. Hoh, D.S. Greenfield, A. Mistlberger Optical coherence tomography and scanning laser polarimetry in normal, ocular hypertensive, and glaucomatous eyes Am J Ophthalmol 129 2000 129 135
    • (2000) Am J Ophthalmol , vol.129 , pp. 129-135
    • Hoh, S.T.1    Greenfield, D.S.2    Mistlberger, A.3
  • 16
    • 0034943558 scopus 로고    scopus 로고
    • Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph
    • L.M. Zangwill, C. Bowd, C.C. Berry Discriminating between normal and glaucomatous eyes using the Heidelberg Retina Tomograph, GDx Nerve Fiber Analyzer, and Optical Coherence Tomograph Arch Ophthalmol 119 2001 985 993
    • (2001) Arch Ophthalmol , vol.119 , pp. 985-993
    • Zangwill, L.M.1    Bowd, C.2    Berry, C.C.3
  • 17
    • 0034909890 scopus 로고    scopus 로고
    • Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function
    • C. Bowd, L.M. Zangwill, C.C. Berry Detecting early glaucoma by assessment of retinal nerve fiber layer thickness and visual function Invest Ophthalmol Vis Sci 42 2001 1993 2003
    • (2001) Invest Ophthalmol Vis Sci , vol.42 , pp. 1993-2003
    • Bowd, C.1    Zangwill, L.M.2    Berry, C.C.3
  • 18
    • 0346729846 scopus 로고    scopus 로고
    • Optical coherence tomography to detect and manage retinal disease and glaucoma
    • G.J. Jaffe, J. Caprioli Optical coherence tomography to detect and manage retinal disease and glaucoma Am J Ophthalmol 137 2004 156 169
    • (2004) Am J Ophthalmol , vol.137 , pp. 156-169
    • Jaffe, G.J.1    Caprioli, J.2
  • 19
    • 0020524559 scopus 로고
    • A method of comparing the areas under receiver operating characteristic curves derived from the same cases
    • J.A. Hanley, B.J. McNeil A method of comparing the areas under receiver operating characteristic curves derived from the same cases Radiology 148 1983 839 843
    • (1983) Radiology , vol.148 , pp. 839-843
    • Hanley, J.A.1    McNeil, B.J.2
  • 21
    • 0020042426 scopus 로고
    • Optic nerve damage in human glaucoma: III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy
    • H.A. Quigley, E.M. Addicks, W.R. Green Optic nerve damage in human glaucoma III. Quantitative correlation of nerve fiber loss and visual field defect in glaucoma, ischemic neuropathy, papilledema, and toxic neuropathy Arch Ophthalmol 100 1982 135 146
    • (1982) Arch Ophthalmol , vol.100 , pp. 135-146
    • Quigley, H.A.1    Addicks, E.M.2    Green, W.R.3
  • 22
    • 0018949713 scopus 로고
    • Band atrophy of the optic nerve: The histology of temporal hemianopsia
    • R. Unsold, W.F. Hoyt Band atrophy of the optic nerve The histology of temporal hemianopsia Arch Ophthalmol 98 1980 1637 1638
    • (1980) Arch Ophthalmol , vol.98 , pp. 1637-1638
    • Unsold, R.1    Hoyt, W.F.2
  • 23
    • 0027300008 scopus 로고
    • Axonal loss in band atrophy of the optic nerve in craniopharyngioma: A quantitative analysis
    • F.S. Mikelberg, H.M. Yidegiligne Axonal loss in band atrophy of the optic nerve in craniopharyngioma: a quantitative analysis Can J Ophthalmol 28 1993 69 71
    • (1993) Can J Ophthalmol , vol.28 , pp. 69-71
    • Mikelberg, F.S.1    Yidegiligne, H.M.2
  • 24
    • 0037377158 scopus 로고    scopus 로고
    • Abnormalities of scanning laser polarimetry associated with pituitary adenoma
    • M. Tanito, N. Itai, T. Goto Abnormalities of scanning laser polarimetry associated with pituitary adenoma Am J Ophthalmol 135 2003 565 567
    • (2003) Am J Ophthalmol , vol.135 , pp. 565-567
    • Tanito, M.1    Itai, N.2    Goto, T.3
  • 25
    • 0033829006 scopus 로고    scopus 로고
    • Effects of artefacts on scanning laser polarimetry of retinal nerve fibre layer thickness measurement
    • S. Kogure, T. Chiba, T. Kinoshita Effects of artefacts on scanning laser polarimetry of retinal nerve fibre layer thickness measurement Br J Ophthalmol 84 2000 1013 1017
    • (2000) Br J Ophthalmol , vol.84 , pp. 1013-1017
    • Kogure, S.1    Chiba, T.2    Kinoshita, T.3
  • 26
    • 0031750197 scopus 로고    scopus 로고
    • Retinal nerve fibre layer polarimetry: Histological and clinical comparison
    • J.E. Morgan, A. Waldock, G. Jeffery, A. Cowey Retinal nerve fibre layer polarimetry: histological and clinical comparison Br J Ophthalmol 82 1998 684 690
    • (1998) Br J Ophthalmol , vol.82 , pp. 684-690
    • Morgan, J.E.1    Waldock, A.2    Jeffery, G.3    Cowey, A.4
  • 27
    • 0023070873 scopus 로고
    • Corneal polarization in the living human eye explained with a biaxial model
    • G.J. Van Blokland, S.C. Verhelst Corneal polarization in the living human eye explained with a biaxial model J Opt Soc Am A 4 1987 82 90
    • (1987) J Opt Soc Am a , vol.4 , pp. 82-90
    • Van Blokland, G.J.1    Verhelst, S.C.2
  • 28
    • 0033858678 scopus 로고    scopus 로고
    • Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry
    • D.S. Greenfield, R.W. Knighton, X.R. Huang Effect of corneal polarization axis on assessment of retinal nerve fiber layer thickness by scanning laser polarimetry Am J Ophthalmol 129 2000 715 722
    • (2000) Am J Ophthalmol , vol.129 , pp. 715-722
    • Greenfield, D.S.1    Knighton, R.W.2    Huang, X.R.3
  • 29
    • 0036240518 scopus 로고    scopus 로고
    • Correction for the erroneous compensation of anterior segment birefringence with the scanning laser polarimeter for glaucoma diagnosis
    • D.F. Garway-Heath, M.J. Greaney, J. Caprioli Correction for the erroneous compensation of anterior segment birefringence with the scanning laser polarimeter for glaucoma diagnosis Invest Ophthalmol Vis Sci 43 2002 1465 1474
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1465-1474
    • Garway-Heath, D.F.1    Greaney, M.J.2    Caprioli, J.3
  • 30
    • 0037314187 scopus 로고    scopus 로고
    • Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation
    • R.N. Weinreb, C. Bowd, L.M. Zangwill Glaucoma detection using scanning laser polarimetry with variable corneal polarization compensation Arch Ophthalmol 12 2003 218 224
    • (2003) Arch Ophthalmol , vol.12 , pp. 218-224
    • Weinreb, R.N.1    Bowd, C.2    Zangwill, L.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.