메뉴 건너뛰기




Volumn 129, Issue 2, 2000, Pages 129-135

Optical coherence tomography and scanning laser polarimetry in normal, ocular hypertensive, and glaucomatous eyes

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ARTICLE; AUTOMATION; DIAGNOSTIC ACCURACY; FEMALE; GLAUCOMA; HUMAN; HUMAN CELL; HUMAN TISSUE; INTRAOCULAR HYPERTENSION; MAJOR CLINICAL STUDY; MALE; OPTICAL COHERENCE TOMOGRAPHY; PERIMETRY; POLARIMETRY; PRIORITY JOURNAL; RETINA NERVE CELL; SCANNING LASER OPHTHALMOSCOPE; THICKNESS; VISUAL FIELD;

EID: 0343048393     PISSN: 00029394     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9394(99)00294-9     Document Type: Article
Times cited : (168)

References (21)
  • 1
    • 0029044003 scopus 로고
    • Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes
    • Weinreb R.N., Shakiba S., Zangwill L. Scanning laser polarimetry to measure the nerve fiber layer of normal and glaucomatous eyes. Am J Ophthalmol. 119:1995;627-636.
    • (1995) Am J Ophthalmol , vol.119 , pp. 627-636
    • Weinreb, R.N.1    Shakiba, S.2    Zangwill, L.3
  • 2
    • 0031890436 scopus 로고    scopus 로고
    • Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry
    • Hoh S.T., Ishikawa H., Greenfield D.S., Liebmann J.M., Chew S.J., Ritch R. Peripapillary nerve fiber layer thickness measurement reproducibility using scanning laser polarimetry. J Glaucoma. 7:1998;12-15.
    • (1998) J Glaucoma , vol.7 , pp. 12-15
    • Hoh, S.T.1    Ishikawa, H.2    Greenfield, D.S.3    Liebmann, J.M.4    Chew, S.J.5    Ritch, R.6
  • 3
    • 0031049984 scopus 로고    scopus 로고
    • The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry
    • Tjon-Fo-Sang M.J., Lemij H.G. The sensitivity and specificity of nerve fiber layer measurements in glaucoma as determined with scanning laser polarimetry. Am J Ophthalmol. 123:1997;62-69.
    • (1997) Am J Ophthalmol , vol.123 , pp. 62-69
    • Tjon-Fo-Sang, M.J.1    Lemij, H.G.2
  • 4
    • 0029851416 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography
    • Schuman J.S., Pedut-Kloizman T., Hertzmark E., et al. Reproducibility of nerve fiber layer thickness measurements using optical coherence tomography. Ophthalmology. 103:1996;1889-1898.
    • (1996) Ophthalmology , vol.103 , pp. 1889-1898
    • Schuman, J.S.1    Pedut-Kloizman, T.2    Hertzmark, E.3
  • 5
    • 0028948087 scopus 로고
    • Optical coherence tomography of the human retina
    • Hee M.R., Izatt J.A., Swanson E.A., et al. Optical coherence tomography of the human retina. Arch Ophthalmol. 113:1995;325-332.
    • (1995) Arch Ophthalmol , vol.113 , pp. 325-332
    • Hee, M.R.1    Izatt, J.A.2    Swanson, E.A.3
  • 6
    • 0031948247 scopus 로고    scopus 로고
    • Reproducibility of retinal thickness measurements in normal eyes using optical coherence tomography
    • Baumann M., Gentile R.C., Liebmann J.M., Ritch R. Reproducibility of retinal thickness measurements in normal eyes using optical coherence tomography. Ophthalmic Surg Lasers. 29:1998;280-285.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 280-285
    • Baumann, M.1    Gentile, R.C.2    Liebmann, J.M.3    Ritch, R.4
  • 7
    • 0001188112 scopus 로고
    • Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal ellipsometer
    • Dreher A.W., Reiter K., Weinreb R.N. Spatially resolved birefringence of the retinal nerve fiber layer assessed with a retinal ellipsometer. Appl Optom. 31:1992;3730-3749.
    • (1992) Appl Optom , vol.31 , pp. 3730-3749
    • Dreher, A.W.1    Reiter, K.2    Weinreb, R.N.3
  • 8
    • 0029068398 scopus 로고
    • Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography
    • Schuman J.S., Hee M.R., Puliafito C.A., et al. Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography. Arch Ophthalmol. 113:1995;586-596.
    • (1995) Arch Ophthalmol , vol.113 , pp. 586-596
    • Schuman, J.S.1    Hee, M.R.2    Puliafito, C.A.3
  • 9
    • 0025329536 scopus 로고
    • Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness
    • Weinreb R.N., Dreher A.W., Coleman A., Quigley H., Shaw B., Reiter K. Histopathologic validation of Fourier-ellipsometry measurements of retinal nerve fiber layer thickness. Arch Ophthalmol. 108:1990;557-560.
    • (1990) Arch Ophthalmol , vol.108 , pp. 557-560
    • Weinreb, R.N.1    Dreher, A.W.2    Coleman, A.3    Quigley, H.4    Shaw, B.5    Reiter, K.6
  • 10
    • 0026254046 scopus 로고
    • Optical coherence tomography
    • Huang D., Swanson E.A., Lin C.P., et al. Optical coherence tomography. Science. 254:1991;1178-1181.
    • (1991) Science , vol.254 , pp. 1178-1181
    • Huang, D.1    Swanson, E.A.2    Lin, C.P.3
  • 11
    • 2642613663 scopus 로고    scopus 로고
    • Factors affecting image acquisition during scanning laser polarimetry
    • Hoh S.T., Greenfield D.S., Ishikawa H., et al. Factors affecting image acquisition during scanning laser polarimetry. Ophthalmic Surg Lasers. 29:1998;545-551.
    • (1998) Ophthalmic Surg Lasers , vol.29 , pp. 545-551
    • Hoh, S.T.1    Greenfield, D.S.2    Ishikawa, H.3
  • 12
    • 0031459317 scopus 로고    scopus 로고
    • Reproducibility of retardation measurements with the Nerve Fiber Analyzer II
    • Zangwill L., Berry C.A., Garden V.S., Weinreb R.N. Reproducibility of retardation measurements with the Nerve Fiber Analyzer II. J Glaucoma. 6:1997;384-389.
    • (1997) J Glaucoma , vol.6 , pp. 384-389
    • Zangwill, L.1    Berry, C.A.2    Garden, V.S.3    Weinreb, R.N.4
  • 13
    • 0027294851 scopus 로고
    • Reproducibility of optic nerve head topography measurements in eyes with undilated pupils
    • Lusky M., Bosem M.E., Weinreb R.N. Reproducibility of optic nerve head topography measurements in eyes with undilated pupils. J Glaucoma. 2:1993;104-109.
    • (1993) J Glaucoma , vol.2 , pp. 104-109
    • Lusky, M.1    Bosem, M.E.2    Weinreb, R.N.3
  • 14
    • 0026058265 scopus 로고
    • Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner
    • Dreher A.W., Tso P.C., Weinreb R.N. Reproducibility of topographic measurements of the normal and glaucomatous optic nerve head with the laser tomographic scanner. Am J Ophthalmol. 111:1991;221.
    • (1991) Am J Ophthalmol , vol.111 , pp. 221
    • Dreher, A.W.1    Tso, P.C.2    Weinreb, R.N.3
  • 15
    • 0027312137 scopus 로고
    • Reproducibility of topographic parameters obtained with the Heidelberg Retina Tomograph
    • Mikelberg F.S., Wijsman K., Schulzer M. Reproducibility of topographic parameters obtained with the Heidelberg Retina Tomograph. J Glaucoma. 2:1993;101-103.
    • (1993) J Glaucoma , vol.2 , pp. 101-103
    • Mikelberg, F.S.1    Wijsman, K.2    Schulzer, M.3
  • 16
    • 0028939507 scopus 로고
    • Correlation of peripapillary retinal height and visual field in glaucoma and normal subjects
    • Tsai C.S., Zangwill L., Sample P.A., Garden V., Bartsch D.-U., Weinreb R.N. Correlation of peripapillary retinal height and visual field in glaucoma and normal subjects. J Glaucoma. 4:1995;110-116.
    • (1995) J Glaucoma , vol.4 , pp. 110-116
    • Tsai, C.S.1    Zangwill, L.2    Sample, P.A.3    Garden, V.4    Bartsch, D.-U.5    Weinreb, R.N.6
  • 17
    • 0028864556 scopus 로고
    • Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma
    • Weinreb R.N., Shakiba S., Sample P.A., et al. Association between quantitative nerve fiber layer measurement and visual field loss in glaucoma. Am J Ophthalmol. 120:1995;732-738.
    • (1995) Am J Ophthalmol , vol.120 , pp. 732-738
    • Weinreb, R.N.1    Shakiba, S.2    Sample, P.A.3
  • 18
    • 0031474377 scopus 로고    scopus 로고
    • A comparison of healthy, ocular hypertensive, and glaucomatous optic disc topographic parameters
    • Iester M., Broadway D.C., Mikelberg F.S., Drance S.M. A comparison of healthy, ocular hypertensive, and glaucomatous optic disc topographic parameters. J Glaucoma. 6:1997;363-370.
    • (1997) J Glaucoma , vol.6 , pp. 363-370
    • Iester, M.1    Broadway, D.C.2    Mikelberg, F.S.3    Drance, S.M.4
  • 19
    • 0029741678 scopus 로고    scopus 로고
    • Measurement by Nerve Fiber Analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension
    • Tjon-Fo-Sang M.J., de Vries J., Lemij H.G. Measurement by Nerve Fiber Analyzer of retinal nerve fiber layer thickness in normal subjects and patients with ocular hypertension. Am J Ophthalmol. 122:1996;220-227.
    • (1996) Am J Ophthalmol , vol.122 , pp. 220-227
    • Tjon-Fo-Sang, M.J.1    De Vries, J.2    Lemij, H.G.3
  • 20
    • 0029738124 scopus 로고    scopus 로고
    • Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy
    • Zangwill L.M., Van Horn S., Lima M.D.S., Sample P.A., Weinreb R.N. Optic nerve head topography in ocular hypertensive eyes using confocal scanning laser ophthalmoscopy. Am J Ophthalmol. 122:1996;520-525.
    • (1996) Am J Ophthalmol , vol.122 , pp. 520-525
    • Zangwill, L.M.1    Van Horn, S.2    Lima, M.D.S.3    Sample, P.A.4    Weinreb, R.N.5
  • 21
    • 0032470784 scopus 로고    scopus 로고
    • Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry
    • Choplin N.T., Lundy D.C., Dreher A.W. Differentiating patients with glaucoma from glaucoma suspects and normal subjects by nerve fiber layer assessment with scanning laser polarimetry. Ophthalmology. 105:1998;2068-2076.
    • (1998) Ophthalmology , vol.105 , pp. 2068-2076
    • Choplin, N.T.1    Lundy, D.C.2    Dreher, A.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.