메뉴 건너뛰기




Volumn 162, Issue 6, 2004, Pages 693-701

Backscatter and dose perturbations for low- to medium-energy electron point sources at the interface between materials with different atomic numbers

Author keywords

[No Author keywords available]

Indexed keywords

RADIOACTIVE MATERIAL;

EID: 9244223044     PISSN: 00337587     EISSN: None     Source Type: Journal    
DOI: 10.1667/RR3271     Document Type: Article
Times cited : (9)

References (27)
  • 1
    • 0029123821 scopus 로고
    • Monte Carlo study of electron spectra and dose from backscattered radiation in the vicinity of media interfaces for monoenergetic photons of 50-1250 keV
    • F. Verhaegen and J. Seuntjens, Monte Carlo study of electron spectra and dose from backscattered radiation in the vicinity of media interfaces for monoenergetic photons of 50-1250 keV. Radiat. Res. 143, 334-342 (1995).
    • (1995) Radiat. Res. , vol.143 , pp. 334-342
    • Verhaegen, F.1    Seuntjens, J.2
  • 2
    • 0029821641 scopus 로고    scopus 로고
    • Perturbation effects in dosimetry: Part I. Kilovoltage x-rays and electrons
    • A. E. Nahum, Perturbation effects in dosimetry: Part I. Kilovoltage x-rays and electrons. Phys. Med. Biol. 41, 1531-1580 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1531-1580
    • Nahum, A.E.1
  • 5
    • 0012787971 scopus 로고    scopus 로고
    • Interface dosimetry for kV and MV photon beams
    • J. Seuntjens and P. Mobit, Eds., Medical Physics Publishing, Madison, WI
    • F. Verhaegen and I. Das, Interface dosimetry for kV and MV photon beams. In Recent Developments in Accurate Radiation Dosimetry (J. Seuntjens and P. Mobit, Eds.), pp. 268-287. Medical Physics Publishing, Madison, WI, 2002.
    • (2002) Recent Developments in Accurate Radiation Dosimetry , pp. 268-287
    • Verhaegen, F.1    Das, I.2
  • 6
    • 0037459548 scopus 로고    scopus 로고
    • Interface perturbation effects in high-energy electron beams
    • F. Verhaegen, Interface perturbation effects in high-energy electron beams. Phys. Med. Biol. 48, 687-705 (2003).
    • (2003) Phys. Med. Biol. , vol.48 , pp. 687-705
    • Verhaegen, F.1
  • 7
    • 0018886276 scopus 로고
    • Electron backscattering
    • N. A. Baily, Electron backscattering. Med. Phys. 7, 514-519 (1980).
    • (1980) Med. Phys. , vol.7 , pp. 514-519
    • Baily, N.A.1
  • 8
    • 0345059774 scopus 로고    scopus 로고
    • Monte Carlo calculations of the dose backscatter factor for monoenergetic electrons
    • S. H. Cho and W. D. Reece, Monte Carlo calculations of the dose backscatter factor for monoenergetic electrons. Phys. Med. Biol. 44, 13-26 (1999).
    • (1999) Phys. Med. Biol. , vol.44 , pp. 13-26
    • Cho, S.H.1    Reece, W.D.2
  • 9
    • 1342330918 scopus 로고    scopus 로고
    • Dose backscatter factors for selected beta sources as a function of source, calcified plaque and contrast agent using Monte Carlo calculations
    • S. W. Lee and W. D. Reece, Dose backscatter factors for selected beta sources as a function of source, calcified plaque and contrast agent using Monte Carlo calculations. Phys. Med. Biol. 49, 583-599 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 583-599
    • Lee, S.W.1    Reece, W.D.2
  • 11
    • 0025188832 scopus 로고
    • Effect of tissue inhomogeneity on dose distribution of point sources of low-energy electrons
    • C. S. Kwok, P. J. Bialobzyski, S. K. Yu and W. V. Prestwich, Effect of tissue inhomogeneity on dose distribution of point sources of low-energy electrons. Med. Phys. 17, 786-793 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 786-793
    • Kwok, C.S.1    Bialobzyski, P.J.2    Yu, S.K.3    Prestwich, W.V.4
  • 12
    • 0025808645 scopus 로고
    • Effect of tissue inhomogeneity on dose distribution of continuous activity of low-energy electrons in bone marrow cavities with different topologies
    • C. S. Kwok, P. J. Bialobzyski and S. K. Yu, Effect of tissue inhomogeneity on dose distribution of continuous activity of low-energy electrons in bone marrow cavities with different topologies. Med. Phys. 18, 533-541 (1991).
    • (1991) Med. Phys. , vol.18 , pp. 533-541
    • Kwok, C.S.1    Bialobzyski, P.J.2    Yu, S.K.3
  • 14
    • 0141452172 scopus 로고    scopus 로고
    • Developments in the internal dosimetry of radiopharmaceuticals
    • M. G. Stabin, Developments in the internal dosimetry of radiopharmaceuticals. Radiat. Prot. Dosim. 105, 575-580 (2003).
    • (2003) Radiat. Prot. Dosim. , vol.105 , pp. 575-580
    • Stabin, M.G.1
  • 15
    • 0029779319 scopus 로고    scopus 로고
    • Microdosimetry and radiocurability: Modelling targeted therapy with beta-emitters
    • A. E. Nahum, Microdosimetry and radiocurability: Modelling targeted therapy with beta-emitters. Phys. Med. Biol. 41, 1957-1972 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 1957-1972
    • Nahum, A.E.1
  • 16
    • 0033972633 scopus 로고    scopus 로고
    • Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes
    • M. G. Stabin and M. W. Konijnenberg, Re-evaluation of absorbed fractions for photons and electrons in spheres of various sizes. J. Nucl. Med. 41, 149-160 (2000).
    • (2000) J. Nucl. Med. , vol.41 , pp. 149-160
    • Stabin, M.G.1    Konijnenberg, M.W.2
  • 17
    • 0025307874 scopus 로고
    • EGS4 Monte Carlo determination of the beta dose kernel in water
    • D. J. Simpkin and T. R. Mackie, EGS4 Monte Carlo determination of the beta dose kernel in water. Med. Phys. 17, 179-186 (1990).
    • (1990) Med. Phys. , vol.17 , pp. 179-186
    • Simpkin, D.J.1    Mackie, T.R.2
  • 18
    • 0028842671 scopus 로고
    • Relationships between tumor size and curability for uniformly targeted therapy with beta-emitting radionuclides
    • J. A. O'Donoghue, M. Bardies and T. E. Wheldon, Relationships between tumor size and curability for uniformly targeted therapy with beta-emitting radionuclides. J. Nucl. Med. 36, 1902-1909 (1995).
    • (1995) J. Nucl. Med. , vol.36 , pp. 1902-1909
    • O'Donoghue, J.A.1    Bardies, M.2    Wheldon, T.E.3
  • 20
    • 0035989990 scopus 로고    scopus 로고
    • Considerations of anthropometric, tissue volume, and tissue mass scaling for improved patient specificity of skeletal S values
    • W. E. Bolch, R. W. Patton, A. R. Shah, D. A. Rajon and D. W. Jokisch, Considerations of anthropometric, tissue volume, and tissue mass scaling for improved patient specificity of skeletal S values. Med. Phys. 29, 1054-1070 (2002).
    • (2002) Med. Phys. , vol.29 , pp. 1054-1070
    • Bolch, W.E.1    Patton, R.W.2    Shah, A.R.3    Rajon, D.A.4    Jokisch, D.W.5
  • 22
    • 0034104708 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version. Med. Phys. 27, 485 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 485
    • Kawrakow, I.1
  • 23
    • 0034023628 scopus 로고    scopus 로고
    • Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations
    • I. Kawrakow, Accurate condensed history Monte Carlo simulation of electron transport. II. Application to ion chamber response simulations. Med. Phys. 27, 499-513 (2000).
    • (2000) Med. Phys. , vol.27 , pp. 499-513
    • Kawrakow, I.1
  • 24
    • 0036229087 scopus 로고    scopus 로고
    • Dose perturbations at high-Z interfaces in kilovoltage photon beams: Comparison with Monte Carlo simulations and measurements
    • I. J. Das, V. P. Moskvin, A. Kassaee, T. Tabata and F. Verhaegen, Dose perturbations at high-Z interfaces in kilovoltage photon beams: comparison with Monte Carlo simulations and measurements. Radiat. Phys. Chem. 64, 173-179 (2002).
    • (2002) Radiat. Phys. Chem. , vol.64 , pp. 173-179
    • Das, I.J.1    Moskvin, V.P.2    Kassaee, A.3    Tabata, T.4    Verhaegen, F.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.