1
-
-
0028899193
-
Interrupting transmission from patients with unsuspected tuberculosis: A unique role for upper-room ultraviolet air disinfection
-
Nardell, E. A. (1995) Interrupting transmission from patients with unsuspected tuberculosis: a unique role for upper-room ultraviolet air disinfection. Am. J. Infect. Control 23, 156-164.
-
(1995)
Am. J. Infect. Control
, vol.23
, pp. 156-164
-
-
Nardell, E.A.1
-
2
-
-
0035700808
-
Estimation of tuberculosis risk and incidence under upper-room ultraviolet germicidal irradiation in a waiting room in a hypothetical scenario
-
Ko, G., H. A. Burge, E. A. Nardell and K. M. Thompson (2001) Estimation of tuberculosis risk and incidence under upper-room ultraviolet germicidal irradiation in a waiting room in a hypothetical scenario. Risk Anal. 4, 657-673.
-
(2001)
Risk Anal.
, vol.4
, pp. 657-673
-
-
Ko, G.1
Burge, H.A.2
Nardell, E.A.3
Thompson, K.M.4
-
3
-
-
0017253040
-
Ultraviolet susceptibility of BCG and virulent tubercle bacilli
-
Riley, R. L., M. Knight and G. Middlebrook (1976) Ultraviolet susceptibility of BCG and virulent tubercle bacilli. Am. Rev. Respir. Dis. 113, 413-418.
-
(1976)
Am. Rev. Respir. Dis.
, vol.113
, pp. 413-418
-
-
Riley, R.L.1
Knight, M.2
Middlebrook, G.3
-
4
-
-
2042548103
-
-
American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., Atlanta, GA
-
First, M. W., E. A. Nardell, W. Chaisson and R. Riley (1999) Guidelines for the Application of Upper-room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion - Parts I and II. American Society of Heating, Refrigeration and Air-Conditioning Engineers, Inc., Atlanta, GA.
-
(1999)
Guidelines for the Application of Upper-room Ultraviolet Germicidal Irradiation for Preventing Transmission of Airborne Contagion - Parts I and II
-
-
First, M.W.1
Nardell, E.A.2
Chaisson, W.3
Riley, R.4
-
5
-
-
0036151232
-
The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms
-
Ko, G., M. W. First and H. A. Burge (2002) The characterization of upper-room ultraviolet germicidal irradiation in inactivating airborne microorganisms. Environ. Health Perspect. 110, 95-101.
-
(2002)
Environ. Health Perspect.
, vol.110
, pp. 95-101
-
-
Ko, G.1
First, M.W.2
Burge, H.A.3
-
6
-
-
0026707513
-
Effect of ultraviolet germicidal lamps on airborne microorganisms in an outpatient waiting room
-
Macher, J. M., L. E. Alevantis, Y. -L Chang and K. -S. Liu (1992) Effect of ultraviolet germicidal lamps on airborne microorganisms in an outpatient waiting room. Appl. Occup. Environ. Hyg. 7, 505-513.
-
(1992)
Appl. Occup. Environ. Hyg.
, vol.7
, pp. 505-513
-
-
Macher, J.M.1
Alevantis, L.E.2
Chang, Y.-L.3
Liu, K.-S.4
-
7
-
-
33947635429
-
Characterization of ultraviolet upper room air disinfection devices
-
Dumyahn, T. and M. First (1999) Characterization of ultraviolet upper room air disinfection devices. Am. Ind. Hyg. Assoc. J. 60, 219-227.
-
(1999)
Am. Ind. Hyg. Assoc. J.
, vol.60
, pp. 219-227
-
-
Dumyahn, T.1
First, M.2
-
8
-
-
0033194783
-
Dosimetry of room-air germicidal (254 nm) radiation using spherical actinometry
-
Rahn, R. O., P. Xu and S. Miller (1999) Dosimetry of room-air germicidal (254 nm) radiation using spherical actinometry. Photochem. Photobiol. 70, 314-318.
-
(1999)
Photochem. Photobiol.
, vol.70
, pp. 314-318
-
-
Rahn, R.O.1
Xu, P.2
Miller, S.3
-
9
-
-
0028845003
-
Estimation of fluence rate from irradiance measurements with a cosine corrected sensor
-
Bjorn, L. O. (1995) Estimation of fluence rate from irradiance measurements with a cosine corrected sensor. J. Photochem. Photobiol. B: Biol. 29, 179-183.
-
(1995)
J. Photochem. Photobiol. B: Biol.
, vol.29
, pp. 179-183
-
-
Bjorn, L.O.1
-
10
-
-
0034460895
-
Effective UVGI system design through improved modeling
-
Kowalski, W. J. and W. P. Bahnfleth (2000) Effective UVGI system design through improved modeling. ASHRAE Trans. 106(2), 4-13.
-
(2000)
ASHRAE Trans.
, vol.106
, Issue.2
, pp. 4-13
-
-
Kowalski, W.J.1
Bahnfleth, W.P.2
-
11
-
-
0032994592
-
A multi-zone model evaluation of the efficiency of upper-room air ultraviolet germicidal irradiation
-
Nicas, M. and S. L. Miller (1999) A multi-zone model evaluation of the efficiency of upper-room air ultraviolet germicidal irradiation. Appl. Occup. Environ. Hyg. 14, 317-328.
-
(1999)
Appl. Occup. Environ. Hyg.
, vol.14
, pp. 317-328
-
-
Nicas, M.1
Miller, S.L.2
-
12
-
-
0034861690
-
Predicting the ultraviolet radiation distribution in a room with multilouvered germicidal fixtures
-
Rudnick, S. N. (2001) Predicting the ultraviolet radiation distribution in a room with multilouvered germicidal fixtures. Am. Ind. Hyg. Assoc. J. 62, 434-445.
-
(2001)
Am. Ind. Hyg. Assoc. J.
, vol.62
, pp. 434-445
-
-
Rudnick, S.N.1
-
13
-
-
0001218464
-
Potassium iodide as a chemical actinometer of 254-nm radiation: Use of iodate as an electron scavenger
-
Rahn, R. O. (1997) Potassium iodide as a chemical actinometer of 254-nm radiation: use of iodate as an electron scavenger. Photochem. Photobiol. 66, 450-455.
-
(1997)
Photochem. Photobiol.
, vol.66
, pp. 450-455
-
-
Rahn, R.O.1
-
14
-
-
0037220814
-
Efficacy of ultraviolet germicidal irradiation of upper-room air in activating airborne bacterial spores and mycobacteria in full-scale studies
-
Xu, Peng, J. Peccia, P. Fabian, J. W. Martyny, K. P. Fennelly, M. Hernandez and S. L. Miller (2003) Efficacy of ultraviolet germicidal irradiation of upper-room air in activating airborne bacterial spores and mycobacteria in full-scale studies. Atmos. Environ. 37, 405-419.
-
(2003)
Atmos. Environ.
, vol.37
, pp. 405-419
-
-
Xu, P.1
Peccia, J.2
Fabian, P.3
Martyny, J.W.4
Fennelly, K.P.5
Hernandez, M.6
Miller, S.L.7
-
16
-
-
0034285029
-
Calculation of ultraviolet fluence rate distributions in an annular reactor: Significance of refraction and reflection
-
Bolton, J. R. (2000) Calculation of ultraviolet fluence rate distributions in an annular reactor: significance of refraction and reflection. Water Res. 34, 3315-3324.
-
(2000)
Water Res.
, vol.34
, pp. 3315-3324
-
-
Bolton, J.R.1
-
17
-
-
0242365543
-
Quantum yield of the iodide-iodate chemical actinometer: Dependence on wavelength and concentration
-
Rahn, R. O., M. Stefan, J. R. Bolton, E. Goren, P. -S. Shaw, and K. R. Lykke (2003) Quantum yield of the iodide-iodate chemical actinometer: dependence on wavelength and concentration. Photochem. Photobiol. 78, 146-152.
-
(2003)
Photochem. Photobiol.
, vol.78
, pp. 146-152
-
-
Rahn, R.O.1
Stefan, M.2
Bolton, J.R.3
Goren, E.4
Shaw, P.-S.5
Lykke, K.R.6
-
19
-
-
0034852923
-
Effects of relative humidity on the ultraviolet induced inactivation of airborne bacteria
-
Peccia, J., H. M. Werth, S. Miller and M. Hernandez (2001) Effects of relative humidity on the ultraviolet induced inactivation of airborne bacteria. Aerosol Sci. Technol. 35, 728-740.
-
(2001)
Aerosol Sci. Technol.
, vol.35
, pp. 728-740
-
-
Peccia, J.1
Werth, H.M.2
Miller, S.3
Hernandez, M.4
|