메뉴 건너뛰기




Volumn 15, Issue 11, 2004, Pages

A new sub-nanosecond LED at 280 nm: Application to protein fluorescence

Author keywords

Fluorescence decay time; Fluorescence lifetime; LED; Light emitting diode; Protein fluorescence; Pulsed optical sources; Sensors

Indexed keywords

FLUORESCENCE; LASER PULSES; PROTEINS; RESEARCH;

EID: 8744238133     PISSN: 09570233     EISSN: None     Source Type: Journal    
DOI: 10.1088/0957-0233/15/11/L02     Document Type: Article
Times cited : (83)

References (20)
  • 2
    • 0036530470 scopus 로고    scopus 로고
    • Nitride semiconductors
    • Akasaki I 2002 Nitride semiconductors J. Cryst. Growth 237-239 905-11
    • (2002) J. Cryst. Growth , vol.237-239 , pp. 905-911
    • Akasaki, I.1
  • 3
    • 0029480979 scopus 로고
    • Light emitting diode-based nanosecond ultraviolet light source for fluorescence lifetime measurements
    • Araki T and Misawa H 1995 Light emitting diode-based nanosecond ultraviolet light source for fluorescence lifetime measurements Rev. Sci. Instrum. 66 5469-72
    • (1995) Rev. Sci. Instrum. , vol.66 , pp. 5469-5472
    • Araki, T.1    Misawa, H.2
  • 4
    • 0033726824 scopus 로고    scopus 로고
    • A pulsed light-emitting-diode system for stimulation of luminescence
    • Chithambo, M L and Galloway R B 2000 A pulsed light-emitting-diode system for stimulation of luminescence Meas. Sci. Technol. 11 418-24
    • (2000) Meas. Sci. Technol. , vol.11 , pp. 418-424
    • Chithambo, M.L.1    Galloway, R.B.2
  • 6
    • 0031100933 scopus 로고    scopus 로고
    • An ultraviolet nanosecond light pulse generator using a light emitting diode for test of photodetectors
    • Araki T, Fujisawa, Y and Hashimoto M 1997 An ultraviolet nanosecond light pulse generator using a light emitting diode for test of photodetectors Rev. Sci. Instrum. 68 1365-8
    • (1997) Rev. Sci. Instrum. , vol.68 , pp. 1365-1368
    • Araki, T.1    Fujisawa, Y.2    Hashimoto, M.3
  • 8
    • 0027958069 scopus 로고
    • The use of fluorescence methods to monitor unfolding transitions in proteins
    • Eftink M R 1994 The use of fluorescence methods to monitor unfolding transitions in proteins Biophys. J. 66 482-502
    • (1994) Biophys. J. , vol.66 , pp. 482-502
    • Eftink, M.R.1
  • 9
    • 0018337803 scopus 로고
    • Subnanosecond motions of tryptophan residues in proteins
    • Munro I, Pecht I and Stryer L 1979 Subnanosecond motions of tryptophan residues in proteins Proc. Natl Acad. Sci. USA 76 56-60
    • (1979) Proc. Natl Acad. Sci. USA , vol.76 , pp. 56-60
    • Munro, I.1    Pecht, I.2    Stryer, L.3
  • 10
    • 0002647421 scopus 로고
    • Laser sources and microchannel plate detectors for pulse fluorometry
    • ed J R Lakowicz (New York: Plenum)
    • Small E W 1991 Laser sources and microchannel plate detectors for pulse fluorometry Topics in Fluorescence Spectroscopy vol 1: Techniques ed J R Lakowicz (New York: Plenum) pp 97-182
    • (1991) Topics in Fluorescence Spectroscopy Techniques , vol.1 , pp. 97-182
    • Small, E.W.1
  • 12
    • 0002983460 scopus 로고
    • Time domain fluorescence spectroscopy using time-correlated single-photon counting
    • ed J R Lakowicz (New York: Plenum)
    • Birch D J S and Imhof R E 1991 Time domain fluorescence spectroscopy using time-correlated single-photon counting Topics in Fluorescence Spectroscopy vol 1: Techniques ed J R Lakowicz (New York: Plenum) pp 1-95
    • (1991) Topics in Fluorescence Spectroscopy Techniques , vol.1 , pp. 1-95
    • Birch, D.J.S.1    Imhof, R.E.2
  • 16
    • 33751158445 scopus 로고
    • Enzymes and other proteins entrapped in sol-gel materials
    • Avnir D, Braun S, Lev O and Ottolenghi M 1994 Enzymes and other proteins entrapped in sol-gel materials Chem. Mater. 6 1605-14
    • (1994) Chem. Mater. , vol.6 , pp. 1605-1614
    • Avnir, D.1    Braun, S.2    Lev, O.3    Ottolenghi, M.4
  • 17
    • 0035872921 scopus 로고    scopus 로고
    • Near-infrared fluorescence lifetime assay for serum glucose based on allophycocyanin-labelled concanavalin A
    • McCartney L J, Pickup J C, Rolinski O J and Birch D J S 2001 Near-infrared fluorescence lifetime assay for serum glucose based on allophycocyanin-labelled concanavalin A Anal. Biochem. 292 216-21
    • (2001) Anal. Biochem. , vol.292 , pp. 216-221
    • McCartney, L.J.1    Pickup, J.C.2    Rolinski, O.J.3    Birch, D.J.S.4
  • 18
    • 0030606337 scopus 로고    scopus 로고
    • Steady-state and time-resolved fluorescence measurements for studying molecular interactions: Interaction of a calcium-binding probe with proteins
    • Hirshfield K M, Toptygin D, Grandhige G, Kim H, Packard B Z and Brand L 1996 Steady-state and time-resolved fluorescence measurements for studying molecular interactions: interaction of a calcium-binding probe with proteins Biophys. Chem. 62 25-38
    • (1996) Biophys. Chem. , vol.62 , pp. 25-38
    • Hirshfield, K.M.1    Toptygin, D.2    Grandhige, G.3    Kim, H.4    Packard, B.Z.5    Brand, L.6
  • 19
    • 33750927821 scopus 로고
    • Fluorescence decay of tryptophan conformers in aqueous solution
    • Szabo A G and Rayner D M 1980 Fluorescence decay of tryptophan conformers in aqueous solution J. Am. Chem. Soc. 102 554-63
    • (1980) J. Am. Chem. Soc. , vol.102 , pp. 554-563
    • Szabo, A.G.1    Rayner, D.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.