-
3
-
-
0029937808
-
Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobinocyanide standard (4th edition)
-
Zwart A, van Assendelft OW, Bull BS, et al. Recommendations for reference method for haemoglobinometry in human blood (ICSH standard 1995) and specifications for international haemiglobinocyanide standard (4th edition). J Clin Pathol 1996;49:271-4.
-
(1996)
J Clin Pathol
, vol.49
, pp. 271-274
-
-
Zwart, A.1
Van Assendelft, O.W.2
Bull, B.S.3
-
4
-
-
0017802956
-
International Committee for standardization in haematology. recommendations for reference method for haemoglobinometry in human blood (ICSH standard EP 6/2: 1977) and specifications for international haemiglobincyanide reference preparation (ICSH standard EP 6/3: 1977)
-
International Committee for Standardization in Haematology
-
International Committee for Standardization in Haematology. International Committee for standardization in haematology. recommendations for reference method for haemoglobinometry in human blood (ICSH standard EP 6/2: 1977) and specifications for international haemiglobincyanide reference preparation (ICSH standard EP 6/3: 1977). J Clin Pathol 1978;31:139-43.
-
(1978)
J Clin Pathol
, vol.31
, pp. 139-143
-
-
-
5
-
-
0034955316
-
Estimating the prevalence of anaemia: A comparison of three methods
-
Sari M, de Pee S, Martini E, et al. Estimating the prevalence of anaemia: A comparison of three methods. Bull World Health Organ 2001;79:506-11.
-
(2001)
Bull World Health Organ
, vol.79
, pp. 506-511
-
-
Sari, M.1
De Pee, S.2
Martini, E.3
-
6
-
-
84961411532
-
Methods for hemoglobin estimation: A review of "what works"
-
Srivastava T, Negandhi H, Neogi SB, et al. Methods for hemoglobin estimation: A review of "what works". J Hematol Transfus 2014;2:1028-35.
-
(2014)
J Hematol Transfus
, vol.2
, pp. 1028-1035
-
-
Srivastava, T.1
Negandhi, H.2
Neogi, S.B.3
-
7
-
-
0023006885
-
Quality control in hematology
-
Gulati GL, Hyun BH. Quality control in hematology. Clin Lab Med 1986;6:675-88.
-
(1986)
Clin Lab Med
, vol.6
, pp. 675-688
-
-
Gulati, G.L.1
Hyun, B.H.2
-
9
-
-
85115872503
-
-
Sysmex XE-2100 Operator's Manual. Kobe Japan
-
Sysmex XE-2100 Operator's Manual. Functional description. Kobe Japan 2007.
-
(2007)
Functional Description
-
-
-
10
-
-
84920896721
-
Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: A method-comparison study
-
Karakochuk CD, Janmohamed A, Whitfield KC, et al. Evaluation of two methods to measure hemoglobin concentration among women with genetic hemoglobin disorders in Cambodia: A method-comparison study. Clin Chim Acta 2015;441:148-55.
-
(2015)
Clin Chim Acta
, vol.441
, pp. 148-155
-
-
Karakochuk, C.D.1
Janmohamed, A.2
Whitfield, K.C.3
-
13
-
-
85115843936
-
Technical letter: Principle of the method/procedure used in the HemoCue Hb 301 system
-
Palsson R. Technical letter: principle of the method/procedure used in the HemoCue Hb 301 system. Angelholm, 2007.
-
(2007)
Angelholm
-
-
Palsson, R.1
-
14
-
-
85007311460
-
A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia
-
Rappaport AI, Karakochuk CD, Whitfield KC, et al. A method comparison study between two hemoglobinometer models (Hemocue Hb 301 and Hb 201+) to measure hemoglobin concentrations and estimate anemia prevalence among women in Preah Vihear, Cambodia. Int J Lab Hematol 2017;39:95-100.
-
(2017)
Int J Lab Hematol
, vol.39
, pp. 95-100
-
-
Rappaport, A.I.1
Karakochuk, C.D.2
Whitfield, K.C.3
-
15
-
-
84858600400
-
Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum Hospital, Sudan
-
Adam I, Ahmed S, Mahmoud MH, et al. Comparison of HemoCue® hemoglobin-meter and automated hematology analyzer in measurement of hemoglobin levels in pregnant women at Khartoum Hospital, Sudan. Diagn Pathol 2012;7:30.
-
(2012)
Diagn Pathol
, vol.7
, pp. 30
-
-
Adam, I.1
Ahmed, S.2
Mahmoud, M.H.3
-
16
-
-
0028085648
-
An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica
-
Hudson-Thomas M, Bingham KC, Simmons WK. An evaluation of the HemoCue for measuring haemoglobin in field studies in Jamaica. Bull World Health Organ 1994;72:423-6.
-
(1994)
Bull World Health Organ
, vol.72
, pp. 423-426
-
-
Hudson-Thomas, M.1
Bingham, K.C.2
Simmons, W.K.3
-
17
-
-
84963668249
-
Diagnostic accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 point-of-care hemoglobin meters in a central laboratory and a community based clinic in Durban, South Africa
-
Jaggernath M, Naicker R, Madurai S, et al. Diagnostic accuracy of the HemoCue Hb 301, STAT-Site MHgb and URIT-12 point-of-care hemoglobin meters in a central laboratory and a community based clinic in Durban, South Africa. PLoS One 2016;11:e0152184.
-
(2016)
PLoS One
, vol.11
, pp. 0e0152184
-
-
Jaggernath, M.1
Naicker, R.2
Madurai, S.3
-
19
-
-
41849147528
-
Comparison of the analytic performance between the B-HB and HB-201+ HemoCue® hemoglobinometers for venous and capillary blood under field work conditions
-
Monárrez-Espino J, Roos N. Comparison of the analytic performance between the B-HB and HB-201+ HemoCue® hemoglobinometers for venous and capillary blood under field work conditions. Ecol Food Nutr 2008;47:159-69.
-
(2008)
Ecol Food Nutr
, vol.47
, pp. 159-169
-
-
Monárrez-Espino, J.1
Roos, N.2
-
20
-
-
68749114145
-
Evaluation of a portable hemoglobin photometer in pregnant women in a high altitude area: A pilot study
-
Zhou X, Yan H, Xing Y, et al. Evaluation of a portable hemoglobin photometer in pregnant women in a high altitude area: A pilot study. BMC Public Health 2009;9:228.
-
(2009)
BMC Public Health
, vol.9
, pp. 228
-
-
Zhou, X.1
Yan, H.2
Xing, Y.3
-
21
-
-
4544365096
-
Comparison between the HemoCue and an automated counter for measuring hemoglobin
-
Paiva AdeA, Rondó PHC, Silva SSdeB, et al. Comparison between the HemoCue and an automated counter for measuring hemoglobin. Rev Saude Publica 2004;38:585-7.
-
(2004)
Rev Saude Publica
, vol.38
, pp. 585-587
-
-
Paiva Dea, A.1
Rondó, P.H.C.2
Silva De S, S.B.3
-
22
-
-
1842846647
-
Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: A validation study
-
Neufeld L, García-Guerra A, Sánchez-Francia D, et al. Hemoglobin measured by Hemocue and a reference method in venous and capillary blood: A validation study. Salud Publica Mex 2002;44:219-27.
-
(2002)
Salud Publica Mex
, vol.44
, pp. 219-227
-
-
Neufeld, L.1
García-Guerra, A.2
Sánchez-Francia, D.3
-
23
-
-
0031966529
-
Measurement of haemoglobin using single drops of skin puncture blood: Is precision acceptable
-
Conway AM, Hinchliffe RF, Earland J, et al. Measurement of haemoglobin using single drops of skin puncture blood: is precision acceptable J Clin Pathol 1998;51:248-50.
-
(1998)
J Clin Pathol
, vol.51
, pp. 248-250
-
-
Conway, A.M.1
Hinchliffe, R.F.2
Earland, J.3
-
24
-
-
84982872963
-
Hemoglobin assessment: Precision and practicability evaluated in the Netherlands-the HAPPEN study
-
Baart AM, de Kort WLAM, van den Hurk K, et al. Hemoglobin assessment: precision and practicability evaluated in the Netherlands-the HAPPEN study. Transfusion 2016;56:1984-93.
-
(2016)
Transfusion
, vol.56
, pp. 1984-1993
-
-
Baart, A.M.1
De Kort, W.L.A.M.2
Van Den Hurk, K.3
-
25
-
-
84876731478
-
Capillary versus venous haemoglobin determination in the assessment of healthy blood donors
-
Patel AJ, Wesley R, Leitman SF, et al. Capillary versus venous haemoglobin determination in the assessment of healthy blood donors. Vox Sang 2013;104:317-23.
-
(2013)
Vox Sang
, vol.104
, pp. 317-323
-
-
Patel, A.J.1
Wesley, R.2
Leitman, S.F.3
-
26
-
-
22144438628
-
Hemoglobin screening in prospective blood donors: Comparison of different blood samples and different quantitative methods
-
Radtke H, Polat G, Kalus U, et al. Hemoglobin screening in prospective blood donors: comparison of different blood samples and different quantitative methods. Transfus Apher Sci 2005;33:31-5.
-
(2005)
Transfus Apher Sci
, vol.33
, pp. 31-35
-
-
Radtke, H.1
Polat, G.2
Kalus, U.3
-
27
-
-
83555174543
-
Reliability of capillary hemoglobin screening under routine conditions
-
Ziemann M, Lizardo B, Geusendam G, et al. Reliability of capillary hemoglobin screening under routine conditions. Transfusion 2011;51:2714-9.
-
(2011)
Transfusion
, vol.51
, pp. 2714-2719
-
-
Ziemann, M.1
Lizardo, B.2
Geusendam, G.3
-
30
-
-
0942287451
-
-
INACG Steering CommiteeNestel P, Washington, D. C
-
INACG Steering CommiteeNestel P. Adjusting hemoglobin values in program surveys. Washington, D. C, 2002. http:// pdf. usaid. gov/ pdf_ docs/ Pnacq927. pdf
-
(2002)
Adjusting Hemoglobin Values in Program Surveys
-
-
-
31
-
-
84908219488
-
Statistical methods for assessing agreement between two methods of clinical measurement
-
Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;1:307-10.
-
(1986)
Lancet
, vol.1
, pp. 307-310
-
-
Bland, J.M.1
Altman, D.G.2
-
32
-
-
0000004140
-
Measurement in medicine: The analysis of method comparison studies
-
Altman DG, Bland JM. Measurement in medicine: The analysis of method comparison studies. J R Stat Soc 1983;32:307-17.
-
(1983)
J R Stat Soc
, vol.32
, pp. 307-317
-
-
Altman, D.G.1
Bland, J.M.2
-
33
-
-
0024521543
-
A concordance correlation coefficient to evaluate reproducibility
-
Lin LI. A concordance correlation coefficient to evaluate reproducibility. Biometrics 1989;45:255-68.
-
(1989)
Biometrics
, vol.45
, pp. 255-268
-
-
Lin, L.I.1
-
34
-
-
0032973798
-
Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood
-
Morris SS, Ruel MT, Cohen RJ, et al. Precision, accuracy, and reliability of hemoglobin assessment with use of capillary blood. Am J Clin Nutr 1999;69:1243-8.
-
(1999)
Am J Clin Nutr
, vol.69
, pp. 1243-1248
-
-
Morris, S.S.1
Ruel, M.T.2
Cohen, R.J.3
-
36
-
-
84882388733
-
Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors
-
Shahshahani HJ, Meraat N, Mansouri F. Evaluation of the validity of a rapid method for measuring high and low haemoglobin levels in whole blood donors. Blood Transfus 2013;11:385-90.
-
(2013)
Blood Transfus
, vol.11
, pp. 385-390
-
-
Shahshahani, H.J.1
Meraat, N.2
Mansouri, F.3
-
37
-
-
85017513639
-
Effects of preanalytical factors on hemoglobin measurement: A comparison of two HemoCue® point-of-care analyzers
-
Whitehead RD, Zhang M, Sternberg MR, et al. Effects of preanalytical factors on hemoglobin measurement: A comparison of two HemoCue® point-of-care analyzers. Clin Biochem 2017;50:513-20.
-
(2017)
Clin Biochem
, vol.50
, pp. 513-520
-
-
Whitehead, R.D.1
Zhang, M.2
Sternberg, M.R.3
-
38
-
-
85068058531
-
Hemoglobin concentration and anemia diagnosis in venous and capillary blood: Biological basis and policy implications
-
Neufeld LM, Larson LM, Kurpad A, et al. Hemoglobin concentration and anemia diagnosis in venous and capillary blood: biological basis and policy implications. Ann N Y Acad Sci 2019;1450:172-89.
-
(2019)
Ann N y Acad Sci
, vol.1450
, pp. 172-189
-
-
Neufeld, L.M.1
Larson, L.M.2
Kurpad, A.3
-
39
-
-
85047894504
-
Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children
-
Hinnouho G-M, Barffour MA, Wessells KR, et al. Comparison of haemoglobin assessments by HemoCue and two automated haematology analysers in young Laotian children. J Clin Pathol 2018;71:532-8.
-
(2018)
J Clin Pathol
, vol.71
, pp. 532-538
-
-
Hinnouho, G.-M.1
Barffour, M.A.2
Wessells, K.R.3
-
40
-
-
79954594760
-
Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting
-
Nkrumah B, Nguah SB, Sarpong N, et al. Hemoglobin estimation by the HemoCue® portable hemoglobin photometer in a resource poor setting. BMC Clin Pathol 2011;11:5.
-
(2011)
BMC Clin Pathol
, vol.11
, pp. 5
-
-
Nkrumah, B.1
Nguah, S.B.2
Sarpong, N.3
-
41
-
-
84947968161
-
Drop-to-drop variation in the cellular components of fingerprick blood: Implications for point-of-care diagnostic development
-
Bond MM, Richards-Kortum RR. Drop-to-drop variation in the cellular components of fingerprick blood: implications for point-of-care diagnostic development. Am J Clin Pathol 2015;144:885-94.
-
(2015)
Am J Clin Pathol
, vol.144
, pp. 885-894
-
-
Bond, M.M.1
Richards-Kortum, R.R.2
-
42
-
-
0029314397
-
High humidity affects HemoCue microcuvette function
-
Henderson MA, Irwin MG. High humidity affects HemoCue microcuvette function. Anaesth Intensive Care 1995;23:407.
-
(1995)
Anaesth Intensive Care
, vol.23
, pp. 407
-
-
Henderson, M.A.1
Irwin, M.G.2
-
43
-
-
0036042209
-
High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia
-
Nguyen HT. High humidity affects HemoCue cuvette function and HemoCue haemoglobin estimation in tropical Australia. J Paediatr Child Health 2002;38:427-8.
-
(2002)
J Paediatr Child Health
, vol.38
, pp. 427-428
-
-
Nguyen, H.T.1
-
44
-
-
67650599131
-
Influence of tourniquet application on venous blood sampling for serum chemistry, hematological parameters, leukocyte activation and erythrocyte mechanical properties
-
Cengiz M, Ulker P, Meiselman HJ, et al. Influence of tourniquet application on venous blood sampling for serum chemistry, hematological parameters, leukocyte activation and erythrocyte mechanical properties. Clin Chem Lab Med 2009;47:769-76.
-
(2009)
Clin Chem Lab Med
, vol.47
, pp. 769-776
-
-
Cengiz, M.1
Ulker, P.2
Meiselman, H.J.3
-
45
-
-
33645793259
-
The influence of the tourniquet time on hematological testing for antidoping purposes
-
Lippi G, Salvagno GL, Solero GP, et al. The influence of the tourniquet time on hematological testing for antidoping purposes. Int J Sports Med 2006;27:359-62.
-
(2006)
Int J Sports Med
, vol.27
, pp. 359-362
-
-
Lippi, G.1
Salvagno, G.L.2
Solero, G.P.3
-
46
-
-
85021244991
-
Variation in haemoglobin measurement across different HemoCue devices and device operators in rural Cambodia
-
Rappaport AI, Barr SI, Green TJ, et al. Variation in haemoglobin measurement across different HemoCue devices and device operators in rural Cambodia. J Clin Pathol 2017;70:615-8.
-
(2017)
J Clin Pathol
, vol.70
, pp. 615-618
-
-
Rappaport, A.I.1
Barr, S.I.2
Green, T.J.3
-
47
-
-
85021843473
-
The effect of oral iron with or without multiple micronutrients on hemoglobin concentration and hemoglobin response among nonpregnant Cambodian women of reproductive age: A 2 X 2 factorial, double-blind, randomized controlled supplementation trial
-
Karakochuk CD, Barker MK, Whitfield KC, et al. The effect of oral iron with or without multiple micronutrients on hemoglobin concentration and hemoglobin response among nonpregnant Cambodian women of reproductive age: A 2 X 2 factorial, double-blind, randomized controlled supplementation trial. Am J Clin Nutr 2017;106:233-44.
-
(2017)
Am J Clin Nutr
, vol.106
, pp. 233-244
-
-
Karakochuk, C.D.1
Barker, M.K.2
Whitfield, K.C.3
-
48
-
-
85040040287
-
An evaluation of hemoglobin measurement tools and their accuracy and reliability when screening for child anemia in Rwanda: A randomized study
-
Parker M, Han Z, Abu-Haydar E, et al. An evaluation of hemoglobin measurement tools and their accuracy and reliability when screening for child anemia in Rwanda: A randomized study. PLoS One 2018;13:e0187663.
-
(2018)
PLoS One
, vol.13
, pp. 0e0187663
-
-
Parker, M.1
Han, Z.2
Abu-Haydar, E.3
|