-
1
-
-
33646852780
-
Characterizing the inflammatory response to cardiopulmonary bypass in children
-
Kozik DJ, Tweddell JS. Characterizing the inflammatory response to cardiopulmonary bypass in children. Ann Thorac Surg 2006;81:S2347–54.
-
(2006)
Ann Thorac Surg
, vol.81
, pp. S2347-S2354
-
-
Kozik, D.J.1
Tweddell, J.S.2
-
2
-
-
0034103920
-
Modeling flow effects on thrombotic deposition in a membrane oxygenator
-
Gartner MJ, Wilhelm CR, Gage KL, Fabrizio MC, Wagner WR. Modeling flow effects on thrombotic deposition in a membrane oxygenator. Artif Organs 2000;24:29–36.
-
(2000)
Artif Organs
, vol.24
, pp. 29-36
-
-
Gartner, M.J.1
Wilhelm, C.R.2
Gage, K.L.3
Fabrizio, M.C.4
Wagner, W.R.5
-
3
-
-
0033019915
-
Hollow fiber membrane contactors
-
Gabelman A, Hwang S-T. Hollow fiber membrane contactors. J Membr Sci 1999;159:61–106.
-
(1999)
J Membr Sci
, vol.159
, pp. 61-106
-
-
Gabelman, A.1
Hwang, S.-T.2
-
5
-
-
0027906728
-
Baffled membrane modules made with hollow fiber fabric
-
Wang KL, Cussler EL. Baffled membrane modules made with hollow fiber fabric. J Membr Sci 1993;85:265–78.
-
(1993)
J Membr Sci
, vol.85
, pp. 265-278
-
-
Wang, K.L.1
Cussler, E.L.2
-
6
-
-
0032491874
-
Absorption of CO2 in a transverse flow hollow fiber membrane module having a few wraps of the fiber mat
-
Bhaumik D, Majumdar S, Sirkar KK. Absorption of CO2 in a transverse flow hollow fiber membrane module having a few wraps of the fiber mat. J Membr Sci 1998;138:77–82.
-
(1998)
J Membr Sci
, vol.138
, pp. 77-82
-
-
Bhaumik, D.1
Majumdar, S.2
Sirkar, K.K.3
-
7
-
-
0036809535
-
Mass and momentum transfer in hollow fibre blood oxygenators
-
Wickramasinghe SR, Garcia JD, Han B. Mass and momentum transfer in hollow fibre blood oxygenators. J Membr Sci 2002;208:247–56.
-
(2002)
J Membr Sci
, vol.208
, pp. 247-256
-
-
Wickramasinghe, S.R.1
Garcia, J.D.2
Han, B.3
-
8
-
-
43449115078
-
A mathematical model to predict CO2 removal in hollow fiber membrane oxygenators
-
Svitek RG, Federspiel WJ. A mathematical model to predict CO2 removal in hollow fiber membrane oxygenators. Ann Biomed Eng 2008;36:992–1003.
-
(2008)
Ann Biomed Eng
, vol.36
, pp. 992-1003
-
-
Svitek, R.G.1
Federspiel, W.J.2
-
9
-
-
85012113122
-
Fiber bundle design for an integrated wearable artificial lung
-
Madhani SP, Frankowski BJ, Federspiel WJ. Fiber bundle design for an integrated wearable artificial lung. ASAIO J 2017;63:631–6.
-
(2017)
ASAIO J
, vol.63
, pp. 631-636
-
-
Madhani, S.P.1
Frankowski, B.J.2
Federspiel, W.J.3
-
10
-
-
85052725944
-
In vitro characterization of the pittsburgh pediatric ambulatory lung
-
(in press)., [Epub ahead of print].
-
Orizondo RA, May AG, Madhani SP, et al. In vitro characterization of the pittsburgh pediatric ambulatory lung. ASAIO J (in press). https://doi.org/10.1097/MAT.0000000000000711. [Epub ahead of print].
-
ASAIO J
-
-
Orizondo, R.A.1
May, A.G.2
Madhani, S.P.3
-
11
-
-
33846636879
-
Characterization of membrane blood oxygenation devices using computational fluid dynamics
-
Zhang J, Nolan TDC, Zhang T, Griffith BP, Wu ZJ. Characterization of membrane blood oxygenation devices using computational fluid dynamics. J Membr Sci 2007;288:268–79.
-
(2007)
J Membr Sci
, vol.288
, pp. 268-279
-
-
Zhang, J.1
Nolan, T.D.C.2
Zhang, T.3
Griffith, B.P.4
Wu, Z.J.5
-
12
-
-
77955659954
-
Micro-scale modeling of flow and oxygen transfer in hollow-fiber membrane bundle
-
Taskin ME, Fraser KH, Zhang T, Griffith BP, Wu ZJ. Micro-scale modeling of flow and oxygen transfer in hollow-fiber membrane bundle. J Membr Sci 2010;362:172–83.
-
(2010)
J Membr Sci
, vol.362
, pp. 172-183
-
-
Taskin, M.E.1
Fraser, K.H.2
Zhang, T.3
Griffith, B.P.4
Wu, Z.J.5
-
13
-
-
79955706450
-
A validated CFD model to predict O2 and CO2 transfer within hollow fiber membrane oxygenators
-
Hormes M, Borchardt R, Mager I, Schmitz-Rode T, Behr M, Steinseifer U. A validated CFD model to predict O2 and CO2 transfer within hollow fiber membrane oxygenators. Int J Artif Organs 2011;34:317–25.
-
(2011)
Int J Artif Organs
, vol.34
, pp. 317-325
-
-
Hormes, M.1
Borchardt, R.2
Mager, I.3
Schmitz-Rode, T.4
Behr, M.5
Steinseifer, U.6
-
14
-
-
14644420027
-
Oxygen transfer to blood flowing in round tubes
-
Weissman MH, Mockros LF. Oxygen transfer to blood flowing in round tubes. J Eng Mech Div 1967;93:225–44.
-
(1967)
J Eng Mech Div
, vol.93
, pp. 225-244
-
-
Weissman, M.H.1
Mockros, L.F.2
-
15
-
-
0022209851
-
Compact cross-flow tubular oxygenators
-
Mockros LF, Leonard R. Compact cross-flow tubular oxygenators. ASAIO J 1985;31:628–33.
-
(1985)
ASAIO J
, vol.31
, pp. 628-633
-
-
Mockros, L.F.1
Leonard, R.2
-
16
-
-
6744269682
-
The kinetics of haemoglobin. iii. the velocity with which oxygen combines with reduced haemoglobin
-
Hartridge H, Roughton FJW. The kinetics of haemoglobin. iii. the velocity with which oxygen combines with reduced haemoglobin. Proc R Soc Lond Ser A 1925;107:654–83.
-
(1925)
Proc R Soc Lond Ser A
, vol.107
, pp. 654-683
-
-
Hartridge, H.1
Roughton, F.J.W.2
-
17
-
-
3042854294
-
The kinetics of human haemoglobin in solution and in the red cell at 37 c
-
Gibson QH, Kreuzer F, Meda E, Roughton FJW. The kinetics of human haemoglobin in solution and in the red cell at 37 c. J Physiol 1955;129:65.
-
(1955)
J Physiol
, vol.129
, pp. 65
-
-
Gibson, Q.H.1
Kreuzer, F.2
Meda, E.3
Roughton, F.J.W.4
-
18
-
-
0014018343
-
Study on the oxygenation velocity of human hemoglobin
-
Mochizuki M, Nakamura K, Oyama Y. Study on the oxygenation velocity of human hemoglobin. Jpn J Physiol 1966;16:519–27.
-
(1966)
Jpn J Physiol
, vol.16
, pp. 519-527
-
-
Mochizuki, M.1
Nakamura, K.2
Oyama, Y.3
-
19
-
-
0014367798
-
The influence of hemoglobin diffusion on oxygen uptake and release by red cells
-
Moll W. The influence of hemoglobin diffusion on oxygen uptake and release by red cells. Respir Physiol 1968;6:1–15.
-
(1968)
Respir Physiol
, vol.6
, pp. 1-15
-
-
Moll, W.1
-
20
-
-
0019295929
-
Transient oxygen transport in hemoglobin layers under conditions of the microcirculation
-
Sheth BV, Hellums JD. Transient oxygen transport in hemoglobin layers under conditions of the microcirculation. Ann Biomed Eng 1980;8:183–96.
-
(1980)
Ann Biomed Eng
, vol.8
, pp. 183-196
-
-
Sheth, B.V.1
Hellums, J.D.2
-
21
-
-
0020935267
-
A simple model for simulation of oxygen transport in the microcirculation
-
Baxley PT, Hellums JD. A simple model for simulation of oxygen transport in the microcirculation. Ann Biomed Eng 1983;11:401–16.
-
(1983)
Ann Biomed Eng
, vol.11
, pp. 401-416
-
-
Baxley, P.T.1
Hellums, J.D.2
-
23
-
-
0024362919
-
Pulmonary diffusing capacity: implications of two-phase blood flow in capillaries
-
Federspiel WJ. Pulmonary diffusing capacity: implications of two-phase blood flow in capillaries. Respir Physiol 1989;77:119–34.
-
(1989)
Respir Physiol
, vol.77
, pp. 119-134
-
-
Federspiel, W.J.1
-
25
-
-
0003950237
-
-
11th Edition, Philadelphia, PA, W. B. Saunders Company, p., 424.
-
Guyton J. Textbook of Medical Physiology, 11th Edition. Philadelphia, PA: W. B. Saunders Company, 2006, p. 505;424.
-
(2006)
Textbook of Medical Physiology
, pp. 505
-
-
Guyton, J.1
-
28
-
-
0014411259
-
Rheological comparison of hemoglobin solutions and erythrocyte suspensions
-
Cokelet GR, Meiselman HJ. Rheological comparison of hemoglobin solutions and erythrocyte suspensions. Science 1968;162:275–7.
-
(1968)
Science
, vol.162
, pp. 275-277
-
-
Cokelet, G.R.1
Meiselman, H.J.2
-
29
-
-
0015411265
-
Improved measurements of the erythrocyte geometry
-
Evans E, Fung Y-C. Improved measurements of the erythrocyte geometry. Microvasc Res 1972;4:335–47.
-
(1972)
Microvasc Res
, vol.4
, pp. 335-347
-
-
Evans, E.1
Fung, Y.-C.2
-
30
-
-
0019732167
-
The effect of the red cell membrane and a diffusion boundary layer on the rate of oxygen uptake by human erythrocytes
-
Huxley VH, Kutchai H. The effect of the red cell membrane and a diffusion boundary layer on the rate of oxygen uptake by human erythrocytes. J Physiol 1981;316:75–83.
-
(1981)
J Physiol
, vol.316
, pp. 75-83
-
-
Huxley, V.H.1
Kutchai, H.2
-
31
-
-
0001108883
-
Fundamental calculations in gravitational processing
-
Schiller L, Naumann A. Fundamental calculations in gravitational processing. Z Ver Dtsch Ingenieure 1933;77:318–20.
-
(1933)
Z Ver Dtsch Ingenieure
, vol.77
, pp. 318-320
-
-
Schiller, L.1
Naumann, A.2
-
32
-
-
33645471525
-
A criterion for non-darcy flow in porous media
-
Zeng Z, Grigg R. A criterion for non-darcy flow in porous media. Transp Porous Media 2006;63:57–69.
-
(2006)
Transp Porous Media
, vol.63
, pp. 57-69
-
-
Zeng, Z.1
Grigg, R.2
-
33
-
-
79960029899
-
-
Stephan P, Kabelac S, Kind M, Martin H, Mewes D, Schaber K. Vdi heat atlas. 2010. https://doi.org/10.1007/978-3-540-77877-6
-
(2010)
Vdi heat atlas
-
-
Stephan, P.1
Kabelac, S.2
Kind, M.3
Martin, H.4
Mewes, D.5
Schaber, K.6
-
34
-
-
46749157511
-
Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies
-
Zierenberg JR, Fujioka H, Cook KE, Grotberg JB. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies. J Biomech Eng 2008;130:031019.
-
(2008)
J Biomech Eng
, vol.130
, pp. 031019
-
-
Zierenberg, J.R.1
Fujioka, H.2
Cook, K.E.3
Grotberg, J.B.4
-
35
-
-
0036592296
-
The iapws formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use
-
Wagner W, Pruß A. The iapws formulation 1995 for the thermodynamic properties of ordinary water substance for general and scientific use. J Phys Chem Ref Data 2002;31:387.
-
(2002)
J Phys Chem Ref Data
, vol.31
, pp. 387
-
-
Wagner, W.1
Pruß, A.2
-
36
-
-
4544292362
-
Evaluation of plasma resistant hollow fiber membranes for artificial lungs
-
Eash HJ, Jones HM, Hattler BG, Federspiel WJ. Evaluation of plasma resistant hollow fiber membranes for artificial lungs. ASAIO J 2004;50:491–7.
-
(2004)
ASAIO J
, vol.50
, pp. 491-497
-
-
Eash, H.J.1
Jones, H.M.2
Hattler, B.G.3
Federspiel, W.J.4
-
37
-
-
77955665036
-
Wetting of polypropylene hollow fiber membrane contactors
-
Lv Y, Yu X, Tu S-T, Yan J, Dahlquist E. Wetting of polypropylene hollow fiber membrane contactors. J Membr Sci 2010;362:444–52.
-
(2010)
J Membr Sci
, vol.362
, pp. 444-452
-
-
Lv, Y.1
Yu, X.2
Tu, S.-T.3
Yan, J.4
Dahlquist, E.5
-
40
-
-
85052734532
-
-
Accessed August, 2017.
-
Membrana Celgard X50–150 Data Sheet. Available at: www.membrana.com, Accessed August, 2017.
-
-
-
-
42
-
-
33744996049
-
Investigating the effects of random balloon pulsation on gas exchange in a respiratory assist catheter
-
Eash HJ, Budilarto SG, Hattler BG, Federspiel WJ. Investigating the effects of random balloon pulsation on gas exchange in a respiratory assist catheter. ASAIO J 2006;52:192–5.
-
(2006)
ASAIO J
, vol.52
, pp. 192-195
-
-
Eash, H.J.1
Budilarto, S.G.2
Hattler, B.G.3
Federspiel, W.J.4
-
43
-
-
34249037352
-
Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter
-
Eash HJ, Mihelc KM, Frankowski BJ, Hattler BG, Federspiel WJ. Evaluation of fiber bundle rotation for enhancing gas exchange in a respiratory assist catheter. ASAIO J 2007;53:368–73.
-
(2007)
ASAIO J
, vol.53
, pp. 368-373
-
-
Eash, H.J.1
Mihelc, K.M.2
Frankowski, B.J.3
Hattler, B.G.4
Federspiel, W.J.5
-
44
-
-
0028519103
-
Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators
-
Vaslef SN, Mockros LF, Anderson RW, Leonard RJ. Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators. ASAIO J 1994;40:990–6.
-
(1994)
ASAIO J
, vol.40
, pp. 990-996
-
-
Vaslef, S.N.1
Mockros, L.F.2
Anderson, R.W.3
Leonard, R.J.4
-
45
-
-
84856655621
-
Analysis of conventional drag and lift models for multiphase cfd modeling of blood flow
-
Yilmaz F, Mehmet Yasar G. Analysis of conventional drag and lift models for multiphase cfd modeling of blood flow. Korea Aust Rheol J 2009;21:161–73.
-
(2009)
Korea Aust Rheol J
, vol.21
, pp. 161-173
-
-
Yilmaz, F.1
Mehmet Yasar, G.2
-
46
-
-
68649096392
-
The cell-free layer in microvascular blood flow
-
Kim S, Ong PK, Yalcin O, Intaglietta M, Johnson PC. The cell-free layer in microvascular blood flow. Biorheology 2009;46:181.
-
(2009)
Biorheology
, vol.46
, pp. 181
-
-
Kim, S.1
Ong, P.K.2
Yalcin, O.3
Intaglietta, M.4
Johnson, P.C.5
-
47
-
-
33645241605
-
Confocal micro-PIV measurements of three-dimensional profiles of cell suspension flow in a square microchannel
-
Lima R, Wada S, Tsubota KI, Yamaguchi T. Confocal micro-PIV measurements of three-dimensional profiles of cell suspension flow in a square microchannel. Meas Sci Technol 2006;17:797.
-
(2006)
Meas Sci Technol
, vol.17
, pp. 797
-
-
Lima, R.1
Wada, S.2
Tsubota, K.I.3
Yamaguchi, T.4
-
48
-
-
0001331302
-
The viscosity of the blood in narrow capillary tubes
-
Fahraeus R, Lindqvist T. The viscosity of the blood in narrow capillary tubes. Am J Physiol 1931;96:562–8.
-
(1931)
Am J Physiol
, vol.96
, pp. 562-568
-
-
-
49
-
-
84938580722
-
Particle image velocimetry used to qualitatively validate computational fluid dynamic simulations in an oxygenator: a proof of concept
-
Schlanstein PC, Hesselmann F, Jansen SV, et al. Particle image velocimetry used to qualitatively validate computational fluid dynamic simulations in an oxygenator: a proof of concept. Cardiovasc Eng Technol 2015;6:340–351.
-
(2015)
Cardiovasc Eng Technol
, vol.6
, pp. 340-351
-
-
Schlanstein, P.C.1
Hesselmann, F.2
Jansen, S.V.3
-
50
-
-
85008255966
-
Experimental approach to visualize flow in a stacked hollow fiber bundle of an artificial lung with particle image velocimetry
-
Kaesler A, Schlanstein PC, Hesselmann F, et al. Experimental approach to visualize flow in a stacked hollow fiber bundle of an artificial lung with particle image velocimetry. Artif Organs 2017;41:529–38.
-
(2017)
Artif Organs
, vol.41
, pp. 529-538
-
-
Kaesler, A.1
Schlanstein, P.C.2
Hesselmann, F.3
|