-
1
-
-
0036130197
-
Results of an artificial-lung survey to lung transplant program directors
-
Haft J.W., Griffith B.P., Hirschl R.B., Bartlett R.H. Results of an artificial-lung survey to lung transplant program directors. J. Heart Lung Transplant. 2002, 21:467-473.
-
(2002)
J. Heart Lung Transplant.
, vol.21
, pp. 467-473
-
-
Haft, J.W.1
Griffith, B.P.2
Hirschl, R.B.3
Bartlett, R.H.4
-
3
-
-
0028519103
-
Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators
-
Vaslef S.N., Mockros L.F., Anderson R.W., Leonard R.J. Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators. ASAIO J. 1994, 40:990-996.
-
(1994)
ASAIO J.
, vol.40
, pp. 990-996
-
-
Vaslef, S.N.1
Mockros, L.F.2
Anderson, R.W.3
Leonard, R.J.4
-
5
-
-
14644420027
-
Oxygen transfer to blood flowing in round tubes
-
Weissman M.H., Mockros L.F. Oxygen transfer to blood flowing in round tubes. J. Eng. Mech. Div. ASCE 1967, 93:225-244.
-
(1967)
J. Eng. Mech. Div. ASCE
, vol.93
, pp. 225-244
-
-
Weissman, M.H.1
Mockros, L.F.2
-
6
-
-
0018034068
-
Mathematical and experimental methods for design and evaluation of membrane oxygenators
-
Eberhart R.C., Dengle S.K., Curtis R.M. Mathematical and experimental methods for design and evaluation of membrane oxygenators. Artif. Organs 1978, 2:19-34.
-
(1978)
Artif. Organs
, vol.2
, pp. 19-34
-
-
Eberhart, R.C.1
Dengle, S.K.2
Curtis, R.M.3
-
7
-
-
0027988634
-
Computer-assisted design of an implantable, intrathoracic artificial lung
-
Vaslef S.N., Mockros L.F., Cook K.E., Leonard R.J., Sung J.C., Anderson R.W. Computer-assisted design of an implantable, intrathoracic artificial lung. Artif. Organs 1994, 18:813-817.
-
(1994)
Artif. Organs
, vol.18
, pp. 813-817
-
-
Vaslef, S.N.1
Mockros, L.F.2
Cook, K.E.3
Leonard, R.J.4
Sung, J.C.5
Anderson, R.W.6
-
8
-
-
0031239388
-
Design of an oxygenator with enhanced gas transfer efficiency
-
Rajasubramanian S., Nelson K.D., Shastri R., Constantinescu A., Kulkarni P., Jessen M.E., Eberhart R.C. Design of an oxygenator with enhanced gas transfer efficiency. ASAIO J. 1997, 43:M714.
-
(1997)
ASAIO J.
, vol.43
-
-
Rajasubramanian, S.1
Nelson, K.D.2
Shastri, R.3
Constantinescu, A.4
Kulkarni, P.5
Jessen, M.E.6
Eberhart, R.C.7
-
10
-
-
0034103920
-
Modeling flow effects on thrombotic deposition in a membrane oxygenator
-
Gartner M.J., Wilhelm C.R., Gage K.L., Fabrizio M.C., Wagner W.R. Modeling flow effects on thrombotic deposition in a membrane oxygenator. Artif. Organs 2000, 24:29-36.
-
(2000)
Artif. Organs
, vol.24
, pp. 29-36
-
-
Gartner, M.J.1
Wilhelm, C.R.2
Gage, K.L.3
Fabrizio, M.C.4
Wagner, W.R.5
-
11
-
-
12844257266
-
Application of CFD (computational fluid dynamics) for the evaluation of pressure drop and velocity distribution in an extracapillary membrane oxygenator
-
Taga I., Funakubo A., Kumagai T., Yasuda T., Ahmed S., Kawamura T., Fukui Y. Application of CFD (computational fluid dynamics) for the evaluation of pressure drop and velocity distribution in an extracapillary membrane oxygenator. Jap. J. Artif. Organs 2000, 29:360-364.
-
(2000)
Jap. J. Artif. Organs
, vol.29
, pp. 360-364
-
-
Taga, I.1
Funakubo, A.2
Kumagai, T.3
Yasuda, T.4
Ahmed, S.5
Kawamura, T.6
Fukui, Y.7
-
12
-
-
0035985026
-
Predicting membrane oxygenator pressure drop using computational fluid dynamics
-
Gage K.L., Gartner M.J., Burgreen G.W., Wagner W.R. Predicting membrane oxygenator pressure drop using computational fluid dynamics. Artif. Organs 2002, 26:600-607.
-
(2002)
Artif. Organs
, vol.26
, pp. 600-607
-
-
Gage, K.L.1
Gartner, M.J.2
Burgreen, G.W.3
Wagner, W.R.4
-
13
-
-
34547690803
-
Modeling of blood flow in a balloon-pulsed intravascular respiratory catheter
-
Zinovik I.N., Federspiel W.J. Modeling of blood flow in a balloon-pulsed intravascular respiratory catheter. ASAIO J. 2007, 43:464-468.
-
(2007)
ASAIO J.
, vol.43
, pp. 464-468
-
-
Zinovik, I.N.1
Federspiel, W.J.2
-
14
-
-
33846636879
-
Characterization of membrane blood oxygenation devices using computational fluid dynamics
-
Zhang J., Nolan T.D.C., Zhang T., Griffith B.P., Wu Z.J. Characterization of membrane blood oxygenation devices using computational fluid dynamics. J. Membr. Sci. 2007, 288:268-279.
-
(2007)
J. Membr. Sci.
, vol.288
, pp. 268-279
-
-
Zhang, J.1
Nolan, T.D.C.2
Zhang, T.3
Griffith, B.P.4
Wu, Z.J.5
-
15
-
-
72449165003
-
Computational design and in vitro characterization of an Integrated Maglev Pump Oxygenator
-
Zhang J., Taskin M.E., Koert A., Zhang T., Gellman B., Dasse K.A., Gilbert R.J., Griffith B.P., Wu Z.J. Computational design and in vitro characterization of an Integrated Maglev Pump Oxygenator. Artif. Organs 2009, 33:805-817.
-
(2009)
Artif. Organs
, vol.33
, pp. 805-817
-
-
Zhang, J.1
Taskin, M.E.2
Koert, A.3
Zhang, T.4
Gellman, B.5
Dasse, K.A.6
Gilbert, R.J.7
Griffith, B.P.8
Wu, Z.J.9
-
16
-
-
41349110472
-
Computational fluid flow and mass transfer of a functionally integrated pediatric-pump oxygenator configuration
-
Fill B., Gartner M., Johnson G., Horner M., Ma J. Computational fluid flow and mass transfer of a functionally integrated pediatric-pump oxygenator configuration. ASAIO J. 2008, 54:214-219.
-
(2008)
ASAIO J.
, vol.54
, pp. 214-219
-
-
Fill, B.1
Gartner, M.2
Johnson, G.3
Horner, M.4
Ma, J.5
-
17
-
-
0031105746
-
Modeling of microporous hollow fiber membrane modules operated under partially wetted conditions
-
Malek A., Li K., Teo W.K. Modeling of microporous hollow fiber membrane modules operated under partially wetted conditions. Ind. Eng. Chem. Res. 1997, 36:784-793.
-
(1997)
Ind. Eng. Chem. Res.
, vol.36
, pp. 784-793
-
-
Malek, A.1
Li, K.2
Teo, W.K.3
-
18
-
-
0034257105
-
A numerical approach to the determination of mass transfer performances through partially wetted microporous membranes: transfer of oxygen to water
-
Evren V. A numerical approach to the determination of mass transfer performances through partially wetted microporous membranes: transfer of oxygen to water. J. Membr. Sci. 2000, 175:97-110.
-
(2000)
J. Membr. Sci.
, vol.175
, pp. 97-110
-
-
Evren, V.1
-
19
-
-
33645681726
-
Pulsatile flow and mass transport past a circular cylinder
-
Zierenberg J.R., Fujioka H., Suresh V., Bartlett R.H., Hirschl R.B., Grotberg J.B. Pulsatile flow and mass transport past a circular cylinder. Phys. Fluids 2006, 18:1-15.
-
(2006)
Phys. Fluids
, vol.18
, pp. 1-15
-
-
Zierenberg, J.R.1
Fujioka, H.2
Suresh, V.3
Bartlett, R.H.4
Hirschl, R.B.5
Grotberg, J.B.6
-
20
-
-
34248172451
-
Pulsatile blood flow and oxygen transport past a circular cylinder
-
Zierenberg J.R., Fujioka H., Hirschl R.B., Bartlett R.H., Grotberg J.B. Pulsatile blood flow and oxygen transport past a circular cylinder. J. Biomech. Eng. 2007, 129:202-215.
-
(2007)
J. Biomech. Eng.
, vol.129
, pp. 202-215
-
-
Zierenberg, J.R.1
Fujioka, H.2
Hirschl, R.B.3
Bartlett, R.H.4
Grotberg, J.B.5
-
21
-
-
33645711207
-
Pulsatile flow and mass transport over an array of cylinders: gas transfer in a cardiac-driven artificial lung
-
Chan K.Y., Fujioka H., Suresh V., Bartlett R.H., Hirschl R.B., Grotberg J.B. Pulsatile flow and mass transport over an array of cylinders: gas transfer in a cardiac-driven artificial lung. J. Biomech. Eng. 2006, 128:85-96.
-
(2006)
J. Biomech. Eng.
, vol.128
, pp. 85-96
-
-
Chan, K.Y.1
Fujioka, H.2
Suresh, V.3
Bartlett, R.H.4
Hirschl, R.B.5
Grotberg, J.B.6
-
22
-
-
46749157511
-
Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies
-
Zierenberg J.R., Fujioka H., Cook K., Grotberg J.B. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies. J. Biomech. Eng. 2008, 130:1-12.
-
(2008)
J. Biomech. Eng.
, vol.130
, pp. 1-12
-
-
Zierenberg, J.R.1
Fujioka, H.2
Cook, K.3
Grotberg, J.B.4
-
23
-
-
0035157666
-
Two-dimensional finite element model for oxygen transfer in cross-flow hollow fiber membrane artificial lung
-
Dierickx P.W., de Wachter D.S., Verdonck P.R. Two-dimensional finite element model for oxygen transfer in cross-flow hollow fiber membrane artificial lung. Int. J. Artif. Organs 2001, 24:628-635.
-
(2001)
Int. J. Artif. Organs
, vol.24
, pp. 628-635
-
-
Dierickx, P.W.1
de Wachter, D.S.2
Verdonck, P.R.3
-
24
-
-
33644971637
-
Uniformity of the flow velocities within hollow fiber membranes of blood oxygenation devices
-
Mazaheri A.R., Ahmadi G. Uniformity of the flow velocities within hollow fiber membranes of blood oxygenation devices. Artif. Organs 2006, 30:10-15.
-
(2006)
Artif. Organs
, vol.30
, pp. 10-15
-
-
Mazaheri, A.R.1
Ahmadi, G.2
-
25
-
-
4544292362
-
Evaluation of plasma resistant hollow fiber membranes for artificial lungs
-
Eash H.J., Jones H.M., Hattler B.G., Federspiel W.J. Evaluation of plasma resistant hollow fiber membranes for artificial lungs. ASAIO J. 2004, 50:491-497.
-
(2004)
ASAIO J.
, vol.50
, pp. 491-497
-
-
Eash, H.J.1
Jones, H.M.2
Hattler, B.G.3
Federspiel, W.J.4
-
26
-
-
27144530660
-
On predicting unsteady non-Newtonian blood flow
-
Gonzalez H.A., Moraga N.O. On predicting unsteady non-Newtonian blood flow. Appl. Math. Comput. 2005, 170:909-923.
-
(2005)
Appl. Math. Comput.
, vol.170
, pp. 909-923
-
-
Gonzalez, H.A.1
Moraga, N.O.2
-
27
-
-
77955665789
-
-
Blood flow in microchannels, Master Theses, Technical University of Denmark
-
L. Bitsch, Blood flow in microchannels, Master Theses, Technical University of Denmark, 2002.
-
(2002)
-
-
Bitsch, L.1
-
28
-
-
0035466302
-
Rheological modeling of Caspian pony blood
-
Hakim S., Morshedian J., Narenji M.R.G., Nia P.K. Rheological modeling of Caspian pony blood. Iran. Polym. J. 2001, 10:293-303.
-
(2001)
Iran. Polym. J.
, vol.10
, pp. 293-303
-
-
Hakim, S.1
Morshedian, J.2
Narenji, M.R.G.3
Nia, P.K.4
-
29
-
-
0001045846
-
Non-Newtonian effects in steady motion of some idealized elastico-viscous liquids
-
Oldroyd J.G. Non-Newtonian effects in steady motion of some idealized elastico-viscous liquids. Proc. R. Soc. Lond. A Math. Phys. Sci. 1958, 245:278-297.
-
(1958)
Proc. R. Soc. Lond. A Math. Phys. Sci.
, vol.245
, pp. 278-297
-
-
Oldroyd, J.G.1
-
30
-
-
77955653605
-
-
Fluent User's Guide version 6.3, Ansys Fluent Inc., Lebanon, NH
-
Fluent User's Guide version 6.3, Ansys Fluent Inc., Lebanon, NH, 2006.
-
(2006)
-
-
-
31
-
-
0027611435
-
Determination of mass transfer rates in wetted and non-wetted microporous membranes
-
Kreulen H., Smolders C.A., Versteeg G.F., Van Swaaij W.P.M. Determination of mass transfer rates in wetted and non-wetted microporous membranes. Chem. Eng. Sci. 1993, 48:2093-2102.
-
(1993)
Chem. Eng. Sci.
, vol.48
, pp. 2093-2102
-
-
Kreulen, H.1
Smolders, C.A.2
Versteeg, G.F.3
Van Swaaij, W.P.M.4
-
32
-
-
34248998775
-
Application of polyimide membranes for biogas purification and enrichment
-
Harasimowicz M., Orluk P., Zakrzewska-Trznadel G., Chmielewski A.G. Application of polyimide membranes for biogas purification and enrichment. J. Hazard. Mater. 2007, 144:698-702.
-
(2007)
J. Hazard. Mater.
, vol.144
, pp. 698-702
-
-
Harasimowicz, M.1
Orluk, P.2
Zakrzewska-Trznadel, G.3
Chmielewski, A.G.4
-
33
-
-
0030596621
-
Gas permeability of hollow fiber membranes in a gas-liquid system
-
Lund L.W., Federspiel W.J., Hattler B.G. Gas permeability of hollow fiber membranes in a gas-liquid system. J. Membr. Sci. 1996, 117:207-219.
-
(1996)
J. Membr. Sci.
, vol.117
, pp. 207-219
-
-
Lund, L.W.1
Federspiel, W.J.2
Hattler, B.G.3
-
34
-
-
0036525066
-
Gas permeance measurement of hollow fiber membranes in gas-liquid environment
-
Lund L.W., Hattler B.G., Federspiel W.J. Gas permeance measurement of hollow fiber membranes in gas-liquid environment. AIChE J. 2002, 48:635-643.
-
(2002)
AIChE J.
, vol.48
, pp. 635-643
-
-
Lund, L.W.1
Hattler, B.G.2
Federspiel, W.J.3
-
36
-
-
0031975898
-
A mathematical model for a gas exchange in an intravenous membrane oxygenator
-
Hewitt T.J., Hattler B.G., Federspiel W.J. A mathematical model for a gas exchange in an intravenous membrane oxygenator. Ann. Biomed. Eng. 1998, 26:166-178.
-
(1998)
Ann. Biomed. Eng.
, vol.26
, pp. 166-178
-
-
Hewitt, T.J.1
Hattler, B.G.2
Federspiel, W.J.3
|