Volumn 24, Issue 7, 2007, Pages 602-608

Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps

Author keywords

Equipment and supplies; Infusion pumps; Syringes

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; FLOW RATE; GRAVIMETRY; INFUSION PUMP; INFUSION RATE; STATISTICAL ANALYSIS; STEADY STATE; SYRINGE; TIME; COMPARATIVE STUDY; DRUG DELIVERY SYSTEM; EQUIPMENT DESIGN; FLOW KINETICS; HUMAN; INSTRUMENTATION; INTRAVENOUS DRUG ADMINISTRATION; METHODOLOGY; PEDIATRICS; REPRODUCIBILITY;

EID: 85047699866     PISSN: 02650215     EISSN: 13652346     Source Type: Journal    
DOI: 10.1017/S0265021507000026     Document Type: Article
Times cited : (45)

References (30)
  • 1
    • 0028044712 scopus 로고
    • Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
    • Rooke GA, Bowdle TA. Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures. Anesth Analg 1994; 78: 150-156.
    • (1994) Anesth Analg , vol.78 , pp. 150-156
    • Rooke, G.A.1    Bowdle, T.A.2
  • 2
    • 0027215610 scopus 로고
    • Dopamine infused continuously at high concentration with a low flow rate affects arterial blood pressure fluctuation waves
    • Shibata H, Aibiki M, Shirakawa Y, Ogli K. Dopamine infused continuously at high concentration with a low flow rate affects arterial blood pressure fluctuation waves. Crit Care Med 1993; 21: 801-804.
    • (1993) Crit Care Med , vol.21 , pp. 801-804
    • Shibata, H.1    Aibiki, M.2    Shirakawa, Y.3    Ogli, K.4
  • 3
    • 0027168847 scopus 로고
    • Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion
    • Klem SA, Farrington JM, Leff RD. Influence of infusion pump operation and flow rate on hemodynamic stability during epinephrine infusion. Crit Care Med 1993; 21: 1213-1217.
    • (1993) Crit Care Med , vol.21 , pp. 1213-1217
    • Klem, S.A.1    Farrington, J.M.2    Leff, R.D.3
  • 4
    • 0029995439 scopus 로고    scopus 로고
    • Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure
    • Krauskopf KH, Rauscher J, Brandt L. Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure. Anaesthesist 1996; 45: 449-452.
    • (1996) Anaesthesist , vol.45 , pp. 449-452
    • Krauskopf, K.H.1    Rauscher, J.2    Brandt, L.3
  • 6
    • 0023150358 scopus 로고
    • Problems in drug therapy for pediatric patients
    • Leff RD, Roberts RJ. Problems in drug therapy for pediatric patients. Am J Hosp Pharm 1987; 44: 865-870.
    • (1987) Am J Hosp Pharm , vol.44 , pp. 865-870
    • Leff, R.D.1    Roberts, R.J.2
  • 8
    • 0030695421 scopus 로고    scopus 로고
    • Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
    • Lonnqvist PA, Lofqvist B. Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intens Care Med 1997; 23: 998-1001.
    • (1997) Intens Care Med , vol.23 , pp. 998-1001
    • Lonnqvist, P.A.1    Lofqvist, B.2
  • 9
    • 0027179741 scopus 로고
    • Cyclical variation of blood pressure and heart rate in neonates
    • Cunningham S, Deere S, McIntosh N. Cyclical variation of blood pressure and heart rate in neonates. Arch Dis Child 1993; 69: 64-67.
    • (1993) Arch Dis Child , vol.69 , pp. 64-67
    • Cunningham, S.1    Deere, S.2    McIntosh, N.3
  • 10
    • 0033945017 scopus 로고    scopus 로고
    • How continuous are continuous drug infusions?
    • Lonnqvist PA. How continuous are continuous drug infusions? Intens Care Med 2000; 26: 660-661.
    • (2000) Intens Care Med , vol.26 , pp. 660-661
    • Lonnqvist, P.A.1
  • 11
    • 0033735621 scopus 로고    scopus 로고
    • Syringe size and flow rate affect drug delivery from syringe pumps
    • Weiss M, Hug MI, Neff T, Fischer J. Syringe size and flow rate affect drug delivery from syringe pumps. Can J Anaesth 2000; 47: 1031-1035.
    • (2000) Can J Anaesth , vol.47 , pp. 1031-1035
    • Weiss, M.1    Hug, M.I.2    Neff, T.3    Fischer, J.4
  • 12
    • 0033692930 scopus 로고    scopus 로고
    • The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps
    • Weiss M, Fischer J, Neff T, Baenziger O. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia 2000; 55: 1094-1098.
    • (2000) Anaesthesia , vol.55 , pp. 1094-1098
    • Weiss, M.1    Fischer, J.2    Neff, T.3    Baenziger, O.4
  • 13
    • 0033936276 scopus 로고    scopus 로고
    • Influence of infusion line compliance on drug delivery rate during acute line loop formation
    • Weiss M, Banziger O, Neff T, Fanconi S. Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intens Care Med 2000; 26: 776-779.
    • (2000) Intens Care Med , vol.26 , pp. 776-779
    • Weiss, M.1    Banziger, O.2    Neff, T.3    Fanconi, S.4
  • 14
    • 0035089356 scopus 로고    scopus 로고
    • Infusion pump performance with vertical displacement: Effect of syringe pump and assembly type
    • Neff TA, Fischer JE, Schulz G, Baenziger O, Weiss M. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intens Care Med 2001; 27: 287-291.
    • (2001) Intens Care Med , vol.27 , pp. 287-291
    • Neff, T.A.1    Fischer, J.E.2    Schulz, G.3    Baenziger, O.4    Weiss, M.5
  • 15
    • 0034991140 scopus 로고    scopus 로고
    • Downward movement of syringe pumps reduces syringe output
    • Kern H, Kuring A, Redlich U et al. Downward movement of syringe pumps reduces syringe output. Br J Anaesth 2001; 86: 828-831.
    • (2001) Br J Anaesth , vol.86 , pp. 828-831
    • Kern, H.1    Kuring, A.2    Redlich, U.3
  • 17
    • 0033751074 scopus 로고    scopus 로고
    • Syringe pump assemblies and the natural history of clinical technology
    • Cook RI. Syringe pump assemblies and the natural history of clinical technology. Can J Anaesth 2000; 47: 929-935.
    • (2000) Can J Anaesth , vol.47 , pp. 929-935
    • Cook, R.I.1
  • 19
    • 0023202060 scopus 로고
    • A gravimetric technique for evaluating flow continuity from two infusion devices
    • Leff RD, True WR, Roberts RJ. A gravimetric technique for evaluating flow continuity from two infusion devices. Am J Hosp Pharm 1987; 44: 1388-1391.
    • (1987) Am J Hosp Pharm , vol.44 , pp. 1388-1391
    • Leff, R.D.1    True, W.R.2    Roberts, R.J.3
  • 20
    • 0023787920 scopus 로고
    • Flow rate variability from electronic infusion devices
    • Stull JC, Erenberg A, Leff RD. Flow rate variability from electronic infusion devices. Crit Care Med 1988; 16: 888-891.
    • (1988) Crit Care Med , vol.16 , pp. 888-891
    • Stull, J.C.1    Erenberg, A.2    Leff, R.D.3
  • 21
    • 0034533613 scopus 로고    scopus 로고
    • The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems
    • Schulz G, Fischer J, Neff T, Banziger O, Weiss M. The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems. Anaesthesist 2000; 49: 1018-1023.
    • (2000) Anaesthesist , vol.49 , pp. 1018-1023
    • Schulz, G.1    Fischer, J.2    Neff, T.3    Banziger, O.4    Weiss, M.5
  • 22
    • 0034031829 scopus 로고    scopus 로고
    • Alteration in flow delivery with antisyphon devices
    • McCarroll C, McAtamney D, Taylor R. Alteration in flow delivery with antisyphon devices. Anaesthesia 2000; 55: 355-357.
    • (2000) Anaesthesia , vol.55 , pp. 355-357
    • McCarroll, C.1    McAtamney, D.2    Taylor, R.3
  • 23
    • 0035926043 scopus 로고    scopus 로고
    • Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems
    • Neff T, Fischer J, Fehr S, Baenziger O, Weiss M. Evaluation of the FASTSTART mode for reducing startup delay in syringe pump infusion systems. Swiss Med Wkly 2001; 131: 219-222.
    • (2001) Swiss Med Wkly , vol.131 , pp. 219-222
    • Neff, T.1    Fischer, J.2    Fehr, S.3    Baenziger, O.4    Weiss, M.5
  • 24
    • 0035834907 scopus 로고    scopus 로고
    • Syringe pumps and start-up time: Ensuring safe practice
    • Amoore J, Dewar D, Ingram P, Lowe D. Syringe pumps and start-up time: ensuring safe practice. Nurs Stand 2001; 15: 43-45.
    • (2001) Nurs Stand , vol.15 , pp. 43-45
    • Amoore, J.1    Dewar, D.2    Ingram, P.3    Lowe, D.4
  • 25
    • 13744259699 scopus 로고    scopus 로고
    • A comparison between single and double-pump syringe changes of intravenous inotropic medications in children
    • Powell ML, Carnevale FA. A comparison between single and double-pump syringe changes of intravenous inotropic medications in children. Dynamics 2004; 15: 10-14.
    • (2004) Dynamics , vol.15 , pp. 10-14
    • Powell, M.L.1    Carnevale, F.A.2
  • 26
    • 2942672258 scopus 로고    scopus 로고
    • Practical considerations in the administration of intravenous vasoactive drugs in the critical care setting: The double pumping or piggyback technique-part one
    • Trim JC, Roe J. Practical considerations in the administration of intravenous vasoactive drugs in the critical care setting: the double pumping or piggyback technique-part one. Intens Crit Care Nurs 2004; 20: 153-160.
    • (2004) Intens Crit Care Nurs , vol.20 , pp. 153-160
    • Trim, J.C.1    Roe, J.2
  • 27
    • 0033058033 scopus 로고    scopus 로고
    • The effect of syringe size on the performance of an infusion pump
    • Kim DW, Steward DJ. The effect of syringe size on the performance of an infusion pump. Paediatr Anaesth 1999; 9: 335-337.
    • (1999) Paediatr Anaesth , vol.9 , pp. 335-337
    • Kim, D.W.1    Steward, D.J.2
  • 28
    • 0033646088 scopus 로고    scopus 로고
    • Impact of infusion line compliance on syringe pump performance
    • Weiss M, Neff T, Gerber A, Fischer J. Impact of infusion line compliance on syringe pump performance. Paediatr Anaesth 2000; 10: 595-599.
    • (2000) Paediatr Anaesth , vol.10 , pp. 595-599
    • Weiss, M.1    Neff, T.2    Gerber, A.3    Fischer, J.4
  • 29
    • 16244365196 scopus 로고    scopus 로고
    • Syringe pumps take too long to give occlusion alarm
    • Donmez A, Araz C, Kayhan Z. Syringe pumps take too long to give occlusion alarm. Paediatr Anaesth 2005; 15: 293-296.
    • (2005) Paediatr Anaesth , vol.15 , pp. 293-296
    • Donmez, A.1    Araz, C.2    Kayhan, Z.3
  • 30
    • 7244251727 scopus 로고    scopus 로고
    • Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): Pump design, evaluation and comparison to the current standard
    • Weiss M, Gerber S, Fuchslin RM, Neff TA. Accurate continuous drug delivery at low infusion rate with a novel microvolumetric infusion pump (MVIP): pump design, evaluation and comparison to the current standard. Anaesthesia 2004; 59: 1133-1137.
    • (2004) Anaesthesia , vol.59 , pp. 1133-1137
    • Weiss, M.1    Gerber, S.2    Fuchslin, R.M.3    Neff, T.A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.