Dopamine infused continuously at high concentration with a low flow rate affects arterial blood pressure fluctuation waves
-
Shibata H, Aibiki M, Shirakawa Y, Ogli K. Dopamine infused continuously at high concentration with a low flow rate affects arterial blood pressure fluctuation waves. Critical Care Medicine 1993; 21: 801-4.
-
(1993)
Critical Care Medicine
, vol.21
, pp. 801-804
-
-
Shibata, H.1
Aibiki, M.2
Shirakawa, Y.3
Ogli, K.4
-
2
-
-
0028044712
-
Syringe pumps for infusion of vasoactive drugs: Mechanical idiosyncrasies and recommended operating procedures
-
Rooke GA, Bowdle TA. Syringe pumps for infusion of vasoactive drugs: mechanical idiosyncrasies and recommended operating procedures. Anesthesia and Analgesia 1994; 78: 150-6.
-
(1994)
Anesthesia and Analgesia
, vol.78
, pp. 150-156
-
-
Rooke, G.A.1
Bowdle, T.A.2
-
3
-
-
0029131840
-
Fluctuations in syringe-pump infusions: Association with blood pressure variations in infants
-
Capes DF, Dunster KR, Sunderland VB, McMillan D, Colditz PB, McDonald C. Fluctuations in syringe-pump infusions: association with blood pressure variations in infants. American Journal of Health-System Pharmacy 1995; 52: 1646-53.
-
(1995)
American Journal of Health-System Pharmacy
, vol.52
, pp. 1646-1653
-
-
Capes, D.F.1
Dunster, K.R.2
Sunderland, V.B.3
McMillan, D.4
Colditz, P.B.5
McDonald, C.6
-
4
-
-
0030695421
-
Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors
-
Lonnqvist PA, Lofqvist B. Design flaw can convert commercially available continuous syringe pumps to intermittent bolus injectors. Intensive Care Medicine 1997; 23: 998-1001.
-
(1997)
Intensive Care Medicine
, vol.23
, pp. 998-1001
-
-
Lonnqvist, P.A.1
Lofqvist, B.2
-
5
-
-
0034991140
-
Downward movement of syringe pumps reduces syringe output
-
Kern H, Kuring A, Redlich U, Dopfmer UR, Sims NM, Spies CD, Kox WJ. Downward movement of syringe pumps reduces syringe output. British Journal of Anaesthesia 2001; 86: 828-31.
-
(2001)
British Journal of Anaesthesia
, vol.86
, pp. 828-831
-
-
Kern, H.1
Kuring, A.2
Redlich, U.3
Dopfmer, U.R.4
Sims, N.M.5
Spies, C.D.6
Kox, W.J.7
-
6
-
-
0035723595
-
Start-up delays of infusion syringe pumps
-
Neff T, Fischer J, Fehr S, Baenziger O, Weiss M. Start-up delays of infusion syringe pumps. Paediatric Anaesthesia 2001; 11: 561-5.
-
(2001)
Paediatric Anaesthesia
, vol.11
, pp. 561-565
-
-
Neff, T.1
Fischer, J.2
Fehr, S.3
Baenziger, O.4
Weiss, M.5
-
7
-
-
0033058033
-
The effect of syringe size on the performance of an infusion pump
-
Kim DW, Steward DJ. The effect of syringe size on the performance of an infusion pump. Paediatric Anaesthesia 1999; 9 335-7.
-
(1999)
Paediatric Anaesthesia
, vol.9
, pp. 335-337
-
-
Kim, D.W.1
Steward, D.J.2
-
8
-
-
0033692930
-
The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps
-
Weiss M, Fischer J, Neff T, Baenziger O. The effects of syringe plunger design on drug delivery during vertical displacement of syringe pumps. Anaesthesia 2000; 55: 1094-8.
-
(2000)
Anaesthesia
, vol.55
, pp. 1094-1098
-
-
Weiss, M.1
Fischer, J.2
Neff, T.3
Baenziger, O.4
-
9
-
-
0035089356
-
Infusion pump performance with vertical displacement: Effect of syringe pump and assembly type
-
Neff TA, Fischer JE, Schulz G, Baenziger O, Weiss M. Infusion pump performance with vertical displacement: effect of syringe pump and assembly type. Intensive Care Medicine 2001; 27: 287-91.
-
(2001)
Intensive Care Medicine
, vol.27
, pp. 287-291
-
-
Neff, T.A.1
Fischer, J.E.2
Schulz, G.3
Baenziger, O.4
Weiss, M.5
-
10
-
-
0033936276
-
Influence of infusion line compliance on drug delivery rate during acute line loop formation
-
Weiss M, Baenziger O, Neff T, Fanconi S. Influence of infusion line compliance on drug delivery rate during acute line loop formation. Intensive Care Medicine 2000; 26: 776-9.
-
(2000)
Intensive Care Medicine
, vol.26
, pp. 776-779
-
-
Weiss, M.1
Baenziger, O.2
Neff, T.3
Fanconi, S.4
-
12
-
-
0035926043
-
Evaluation of the FASTSTART mode for reducing start-up delay in syringe pump infusion systems
-
Neff T, Fischer J, Fehr S, Baenziger O, Weiss M. Evaluation of the FASTSTART mode for reducing start-up delay in syringe pump infusion systems. Swiss Medical Weekly 2001; 131: 219-22.
-
(2001)
Swiss Medical Weekly
, vol.131
, pp. 219-222
-
-
Neff, T.1
Fischer, J.2
Fehr, S.3
Baenziger, O.4
Weiss, M.5
-
13
-
-
0033751074
-
Syringe pump assemblies and the natural history of clinical technology
-
Cook RI. Syringe pump assemblies and the natural history of clinical technology. Canadian Journal of Anaesthesia 2000; 47 929-35.
-
(2000)
Canadian Journal of Anaesthesia
, vol.47
, pp. 929-935
-
-
Cook, R.I.1
-
14
-
-
0033945017
-
How continuous are continuous drug infusions?
-
Lonnqvist PA. How continuous are continuous drug infusions? Intensive Care Medicine 2000; 26: 660-1.
-
(2000)
Intensive Care Medicine
, vol.26
, pp. 660-661
-
-
Lonnqvist, P.A.1
-
15
-
-
0023202060
-
A gravimetric technique for evaluating flow continuity from two infusion devices
-
Leff RD, True WR, Roberts RJ. A gravimetric technique for evaluating flow continuity from two infusion devices. American Journal of Hospital Pharmacy 1987; 44: 1388-91.
-
(1987)
American Journal of Hospital Pharmacy
, vol.44
, pp. 1388-1391
-
-
Leff, R.D.1
True, W.R.2
Roberts, R.J.3
-
17
-
-
0028136860
-
Overdosage of opiate from patient controlled analgesia devices
-
Southern DA, Read MS. Overdosage of opiate from patient controlled analgesia devices. British Medical Journal 1994; 309 1002.
-
(1994)
British Medical Journal
, vol.309
, pp. 1002
-
-
Southern, D.A.1
Read, M.S.2
-
18
-
-
0031784823
-
Infusion devices: Most do not measure the volume infused
-
Amoore J, Mather J, Scott DH, Craig K. Infusion devices: most do not measure the volume infused. Anaesthesia 1998; 53: 1231-2.
-
(1998)
Anaesthesia
, vol.53
, pp. 1231-1232
-
-
Amoore, J.1
Mather, J.2
Scott, D.H.3
Craig, K.4
|