메뉴 건너뛰기




Volumn 91, Issue 1090, 2018, Pages

Influence of lung nodule margin on volume- and diameter-based reader variability in cT lung cancer screening

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER ASSISTED DIAGNOSIS; DIAGNOSTIC IMAGING; HUMAN; LUNG NODULE; LUNG TUMOR; MIDDLE AGED; PATHOLOGY; PROCEDURES; RADIATION DOSE; X-RAY COMPUTED TOMOGRAPHY;

EID: 85046279056     PISSN: 00071285     EISSN: 1748880X     Source Type: Journal    
DOI: 10.1259/bjr.20170405     Document Type: Article
Times cited : (36)

References (33)
  • 1
    • 79961108629 scopus 로고    scopus 로고
    • Reduced lung-cancer mortality with low-dose computed tomographic screening
    • National Lung Screening Trial Research Team, Aberle DR, Adams AM, Berg CD, Black WC, Clapp JD, et al. Reduced lung-cancer mortality with low-dose computed tomographic screening. N Engl J Med 2011; 365: 395-409. doi: https://doi.org/10.1056/ NEJMoa1102873
    • (2011) N Engl J Med , vol.365 , pp. 395-409
    • Aberle, D.R.1    Adams, A.M.2    Berg, C.D.3    Black, W.C.4    Clapp, J.D.5
  • 2
    • 84883136945 scopus 로고    scopus 로고
    • National lung screening trial: Variability in nodule detection rates in chest CT studies
    • Pinsky PF, Gierada DS, Nath PH, Kazerooni E, Amorosa J. National lung screening trial: variability in nodule detection rates in chest CT studies. Radiology 2013; 268: 865-73. doi: https://doi.org/10.1148/radiol.13121530
    • (2013) Radiology , vol.268 , pp. 865-873
    • Pinsky, P.F.1    Gierada, D.S.2    Nath, P.H.3    Kazerooni, E.4    Amorosa, J.5
  • 3
    • 84940823468 scopus 로고    scopus 로고
    • British Thoracic Society guidelines for the investigation and management of pulmonary nodules
    • Callister ME, Baldwin DR, Akram AR, Barnard S, Cane P, Draffan J, et al. British Thoracic Society guidelines for the investigation and management of pulmonary nodules. Thorax 2015; 70(Suppl 2): ii1-ii54. doi: https://doi.org/10.1136/thoraxjnl-2015-207168
    • (2015) Thorax , vol.70 , pp. ii1-ii54
    • Callister, M.E.1    Baldwin, D.R.2    Akram, A.R.3    Barnard, S.4    Cane, P.5    Draffan, J.6
  • 4
    • 85013195816 scopus 로고    scopus 로고
    • American College of Radiology. cited 10 August 2016
    • Lung CT Screening Reporting and Data System (Lung-RADSTM). American College of Radiology. 2016. Available from: http://www.acr.org/Quality-Safety/Resources/LungRADS [cited 10 August 2016].
    • (2016) Lung CT Screening Reporting and Data System (Lung-RADSTM)
  • 5
    • 85019903375 scopus 로고    scopus 로고
    • Guidelines for management of incidental pulmonary nodules detected on CT images: From the fleischner society 2017
    • MacMahon H, Naidich DP, Goo JM, Lee KS, Leung ANC, Mayo JR, et al. Guidelines for management of incidental pulmonary nodules detected on CT images: from the fleischner society 2017. Radiology 2017; 284: 228-43. doi: https://doi.org/10.1148/radiol.2017161659
    • (2017) Radiology , vol.284 , pp. 228-243
    • MacMahon, H.1    Naidich, D.P.2    Goo, J.M.3    Lee, K.S.4    Leung, A.N.C.5    Mayo, J.R.6
  • 8
    • 84871267369 scopus 로고    scopus 로고
    • Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- And 64-row multi-detector CT: An anthropomorphic phantom study
    • Xie X, Zhao Y, Snijder RA, van Ooijen PM, de Jong PA, Oudkerk M, et al. Sensitivity and accuracy of volumetry of pulmonary nodules on low-dose 16- and 64-row multi-detector CT: an anthropomorphic phantom study. Eur Radiol 2013; 23: 139-47. doi: https://doi.org/10.1007/s00330-012-2570-7
    • (2013) Eur Radiol , vol.23 , pp. 139-147
    • Xie, X.1    Zhao, Y.2    Snijder, R.A.3    Van Ooijen, P.M.4    De Jong, P.A.5    Oudkerk, M.6
  • 10
    • 34248632699 scopus 로고    scopus 로고
    • Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners
    • Das M, Ley-Zaporozhan J, Gietema HA, Czech A, Mühlenbruch G, Mahnken AH, et al. Accuracy of automated volumetry of pulmonary nodules across different multislice CT scanners. Eur Radiol 2007; 17: 1979-84. doi: https://doi.org/10.1007/ s00330-006-0562-1
    • (2007) Eur Radiol , vol.17 , pp. 1979-1984
    • Das, M.1    Ley-Zaporozhan, J.2    Gietema, H.A.3    Czech, A.4    Mühlenbruch, G.5    Mahnken, A.H.6
  • 11
    • 3342880848 scopus 로고    scopus 로고
    • Flat panel detector-based volumetric CT: Prototype evaluation with volumetry of small artificial nodules in a pulmonary phantom
    • Marten K, Funke M, Engelke C. Flat panel detector-based volumetric CT: prototype evaluation with volumetry of small artificial nodules in a pulmonary phantom. J Thorac Imaging 2004; 19: 156-63.
    • (2004) J Thorac Imaging , vol.19 , pp. 156-163
    • Marten, K.1    Funke, M.2    Engelke, C.3
  • 12
    • 2342550126 scopus 로고    scopus 로고
    • Characterization of small nodules by automatic segmentation of X-ray computed tomography images
    • Tao P, Griess F, Lvov Y, Mineyev M, Zhao B, Levin D, et al. Characterization of small nodules by automatic segmentation of X-ray computed tomography images. J Comput Assist Tomogr 2004; 28: 372-7.
    • (2004) J Comput Assist Tomogr , vol.28 , pp. 372-377
    • Tao, P.1    Griess, F.2    Lvov, Y.3    Mineyev, M.4    Zhao, B.5    Levin, D.6
  • 13
    • 42649084308 scopus 로고    scopus 로고
    • Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: A phantom study
    • Way TW, Chan HP, Goodsitt MM, Sahiner B, Hadjiiski LM, Zhou C, et al. Effect of CT scanning parameters on volumetric measurements of pulmonary nodules by 3D active contour segmentation: a phantom study. Phys Med Biol 2008; 53: 1295-312. doi: https://doi.org/10.1088/0031-9155/53/5/009
    • (2008) Phys Med Biol , vol.53 , pp. 1295-1312
    • Way, T.W.1    Chan, H.P.2    Goodsitt, M.M.3    Sahiner, B.4    Hadjiiski, L.M.5    Zhou, C.6
  • 14
    • 0034538087 scopus 로고    scopus 로고
    • Small pulmonary nodules: Volumetrically determined growth rates based on CT evaluation
    • Yankelevitz DF, Reeves AP, Kostis WJ, Zhao B, Henschke CI. Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation. Radiology 2000; 217: 251-6. doi: https://doi.org/10.1148/radiology.217.1.r00oc33251
    • (2000) Radiology , vol.217 , pp. 251-256
    • Yankelevitz, D.F.1    Reeves, A.P.2    Kostis, W.J.3    Zhao, B.4    Henschke, C.I.5
  • 15
    • 42749089755 scopus 로고    scopus 로고
    • Limited value of shape, margin and CT density in the discrimination between benign and malignant screen detected solid pulmonary nodules of the NELSON trial
    • Xu DM, van Klaveren RJ, de Bock GH, Leusveld A, Zhao Y, Wang Y, et al. Limited value of shape, margin and CT density in the discrimination between benign and malignant screen detected solid pulmonary nodules of the NELSON trial. Eur J Radiol 2008; 68: 347-52. doi: https://doi.org/10.1016/j.ejrad.2007.08.027
    • (2008) Eur J Radiol , vol.68 , pp. 347-352
    • Xu, D.M.1    Van Klaveren, R.J.2    De Bock, G.H.3    Leusveld, A.4    Zhao, Y.5    Wang, Y.6
  • 16
    • 58149355207 scopus 로고    scopus 로고
    • Smooth or attached solid indeterminate nodules detected at baseline CT screening in the NELSON study: Cancer risk during 1 year of follow-up
    • Xu DM, van der Zaag-Loonen HJ, Oudkerk M, Wang Y, Vliegenthart R, Scholten ET, et al. Smooth or attached solid indeterminate nodules detected at baseline CT screening in the NELSON study: cancer risk during 1 year of follow-up. Radiology 2009; 250: 264-72. doi: https://doi.org/10.1148/radiol.2493070847
    • (2009) Radiology , vol.250 , pp. 264-272
    • Xu, D.M.1    Van Der Zaag-Loonen, H.J.2    Oudkerk, M.3    Wang, Y.4    Vliegenthart, R.5    Scholten, E.T.6
  • 17
    • 33751348788 scopus 로고    scopus 로고
    • Nodule management protocol of the NELSON randomised lung cancer screening trial
    • Xu DM, Gietema H, de Koning H, Vernhout R, Nackaerts K, Prokop M, et al. Nodule management protocol of the NELSON randomised lung cancer screening trial. Lung Cancer 2006; 54: 177-84. doi: https://doi.org/10.1016/j.lungcan.2006.08. 006
    • (2006) Lung Cancer , vol.54 , pp. 177-184
    • Xu, D.M.1    Gietema, H.2    De Koning, H.3    Vernhout, R.4    Nackaerts, K.5    Prokop, M.6
  • 18
    • 33846564385 scopus 로고    scopus 로고
    • Risk-based selection from the general population in a screening trial: Selection criteria, recruitment and power for the Dutch-Belgian randomised lung cancer multi-slice CT screening trial (NELSON)
    • van Iersel CA, de Koning HJ, Draisma G, Mali W, Scholten ET, Nackaerts K, et al. Risk-based selection from the general population in a screening trial: selection criteria, recruitment and power for the Dutch-Belgian randomised lung cancer multi-slice CT screening trial (NELSON). Int J Cancer J Int Cancer 2007; 120: 868-74.
    • (2007) Int J Cancer J Int Cancer , vol.120 , pp. 868-874
    • Van Iersel, C.A.1    De Koning, H.J.2    Draisma, G.3    Mali, W.4    Scholten, E.T.5    Nackaerts, K.6
  • 19
    • 85054640066 scopus 로고    scopus 로고
    • P1.03-052 the effect of rounding on rate of positive results on CT screening for Lung Cancer
    • Li K, Yip R, Avila R, Henschke C, Yankelevitz D. P1.03-052 the effect of rounding on rate of positive results on CT screening for Lung Cancer. J Thorac Oncol 2017; 12: S575. doi: https://doi.org/10.1016/j.jtho.2016.11.723
    • (2017) J Thorac Oncol , vol.12 , pp. S575
    • Li, K.1    Yip, R.2    Avila, R.3    Henschke, C.4    Yankelevitz, D.5
  • 20
    • 0344405715 scopus 로고    scopus 로고
    • Small solitary pulmonary nodules (< or =1 cm) detected at population-based CT screening for lung cancer: Reliable high-resolution CT features of benign lesions
    • Takashima S, Sone S, Li F, Maruyama Y, Hasegawa M, Matsushita T, et al. Small solitary pulmonary nodules (< or =1 cm) detected at population-based CT screening for lung cancer: reliable high-resolution CT features of benign lesions. AJR Am J Roentgenol 2003; 180: 955-64.
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 955-964
    • Takashima, S.1    Sone, S.2    Li, F.3    Maruyama, Y.4    Hasegawa, M.5    Matsushita, T.6
  • 21
    • 0242432449 scopus 로고    scopus 로고
    • Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung: Using first follow-up diagnostic CT to differentiate benign and malignant lesions
    • Takashima S, Sone S, Li F, Maruyama Y, Hasegawa M, Kadoya M. Indeterminate solitary pulmonary nodules revealed at population-based CT screening of the lung: using first follow-up diagnostic CT to differentiate benign and malignant lesions. AJR Am J Roentgenol 2003; 180: 1255-63. doi: https://doi.org/10.2214/ajr.180.5.1801255
    • (2003) AJR Am J Roentgenol , vol.180 , pp. 1255-1263
    • Takashima, S.1    Sone, S.2    Li, F.3    Maruyama, Y.4    Hasegawa, M.5    Kadoya, M.6
  • 22
    • 80755144008 scopus 로고    scopus 로고
    • A graphical method for assessing agreement with the mean between multiple observers using continuous measures
    • Jones M, Dobson A, O'Brian S. A graphical method for assessing agreement with the mean between multiple observers using continuous measures. Int J Epidemiol 2011; 40: 1308-13. doi: https://doi.org/10.1093/ije/ dyr109
    • (2011) Int J Epidemiol , vol.40 , pp. 1308-1313
    • Jones, M.1    Dobson, A.2    O'Brian, S.3
  • 23
    • 33748923799 scopus 로고    scopus 로고
    • Pulmonary nodules detected at lung cancer screening: Interobserver variability of semiautomated volume measurements
    • Gietema HA, Wang Y, Xu D, van Klaveren RJ, de Koning H, Scholten E, et al. Pulmonary nodules detected at lung cancer screening: interobserver variability of semiautomated volume measurements. Radiology 2006; 241: 251-7. doi: https://doi.org/10.1148/radiol. 2411050860
    • (2006) Radiology , vol.241 , pp. 251-257
    • Gietema, H.A.1    Wang, Y.2    Xu, D.3    Van Klaveren, R.J.4    De Koning, H.5    Scholten, E.6
  • 24
    • 34250756132 scopus 로고    scopus 로고
    • Answering the call for a standard reliability measure for coding data
    • Hayes AF, Krippendorff K. Answering the call for a standard reliability measure for coding data. Commun Methods Meas 2007; 1: 77-89.
    • (2007) Commun Methods Meas , vol.1 , pp. 77-89
    • Hayes, A.F.1    Krippendorff, K.2
  • 25
    • 4043124032 scopus 로고    scopus 로고
    • Reliability in content analysis: Some common misconceptions and recommendations
    • Krippendorff K. Reliability in content analysis: some common misconceptions and recommendations. Hum Commun Res 2004;: 411-33.
    • (2004) Hum Commun Res , pp. 411-433
    • Krippendorff, K.1
  • 28
    • 0025756404 scopus 로고
    • Solitary pulmonary nodule: High-resolution CT and radiologic-pathologic correlation
    • Zwirewich CV, Vedal S, Miller RR, Müller NL. Solitary pulmonary nodule: high-resolution CT and radiologic-pathologic correlation. Radiology 1991; 179: 469-76. doi: https://doi.org/10.1148/radiology.179.2. 2014294
    • (1991) Radiology , vol.179 , pp. 469-476
    • Zwirewich, C.V.1    Vedal, S.2    Miller, R.R.3    Müller, N.L.4
  • 29
    • 84895474256 scopus 로고    scopus 로고
    • Features of resolving and nonresolving indeterminate pulmonary nodules at followup CT: The NELSON study
    • Zhao YR, Heuvelmans MA, Dorrius MD, van Ooijen PM, Wang Y, de Bock GH, et al. Features of resolving and nonresolving indeterminate pulmonary nodules at followup CT: the NELSON study. Radiology 2014; 270: 872-9. doi: https://doi.org/10.1148/radiol.13130332
    • (2014) Radiology , vol.270 , pp. 872-879
    • Zhao, Y.R.1    Heuvelmans, M.A.2    Dorrius, M.D.3    Van Ooijen, P.M.4    Wang, Y.5    De Bock, G.H.6
  • 30
    • 2142697951 scopus 로고    scopus 로고
    • Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable?
    • Revel MP, Bissery A, Bienvenu M, Aycard L, Lefort C, Frija G. Are two-dimensional CT measurements of small noncalcified pulmonary nodules reliable? Radiology 2004; 231: 453-8. doi: https://doi.org/10.1148/radiol.2312030167
    • (2004) Radiology , vol.231 , pp. 453-458
    • Revel, M.P.1    Bissery, A.2    Bienvenu, M.3    Aycard, L.4    Lefort, C.5    Frija, G.6
  • 31
    • 84890149161 scopus 로고    scopus 로고
    • Comparison of 1D, 2D, and 3D nodule sizing methods by radiologists for spherical and complex nodules on thoracic CT phantom images
    • Petrick N, Kim HJ, Clunie D, Borradaile K, Ford R, Zeng R, et al. Comparison of 1D, 2D, and 3D nodule sizing methods by radiologists for spherical and complex nodules on thoracic CT phantom images. Acad Radiol 2014; 21: 30-40. doi: https://doi.org/10.1016/j.acra.2013.09.020
    • (2014) Acad Radiol , vol.21 , pp. 30-40
    • Petrick, N.1    Kim, H.J.2    Clunie, D.3    Borradaile, K.4    Ford, R.5    Zeng, R.6
  • 33
    • 62649137035 scopus 로고    scopus 로고
    • A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations
    • de Hoop B, Gietema H, van Ginneken B, Zanen P, Groenewegen G, Prokop M. A comparison of six software packages for evaluation of solid lung nodules using semiautomated volumetry: what is the minimum increase in size to detect growth in repeated CT examinations. Eur Radiol 2009; 19: 800-8. doi: https://doi.org/10.1007/s00330-008-1229-x
    • (2009) Eur Radiol , vol.19 , pp. 800-808
    • De Hoop, B.1    Gietema, H.2    Van Ginneken, B.3    Zanen, P.4    Groenewegen, G.5    Prokop, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.