-
1
-
-
0031266643
-
Iliosacral screw fixation: early complications of the percutaneous technique
-
Routt MC Jr, Simonian PT, Mills WJ (1997) Iliosacral screw fixation: early complications of the percutaneous technique. J Orthop Trauma 11(8):584–589
-
(1997)
J Orthop Trauma
, vol.11
, Issue.8
, pp. 584-589
-
-
Routt, M.C.1
Simonian, P.T.2
Mills, W.J.3
-
2
-
-
77951787510
-
The „safe zone“ for extraarticular screw placement during intrapelvic acetabular surgery
-
Guy P, Al-Otaibi M, Harvey EJ, Helmy N (2010) The „safe zone“ for extraarticular screw placement during intrapelvic acetabular surgery. J Orthop Trauma 24(5):279–283
-
(2010)
J Orthop Trauma
, vol.24
, Issue.5
, pp. 279-283
-
-
Guy, P.1
Al-Otaibi, M.2
Harvey, E.J.3
Helmy, N.4
-
3
-
-
34247136630
-
Image guidance in pelvic and acetabular surgery expectations, success and limitations
-
Stöckle U, Schaser K, König B (2007) Image guidance in pelvic and acetabular surgery expectations, success and limitations. Injury 38(4):450–462
-
(2007)
Injury
, vol.38
, Issue.4
, pp. 450-462
-
-
Stöckle, U.1
Schaser, K.2
König, B.3
-
4
-
-
35948991068
-
Navigating the fluoroscope’s C‑arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow
-
Matthews F, Hoigne DJ, Weiser M, Wanner GA, Regazzoni P, Suhm N, Messmer P (2007) Navigating the fluoroscope’s C‑arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow. J Orthop Trauma 21(10):687–692
-
(2007)
J Orthop Trauma
, vol.21
, Issue.10
, pp. 687-692
-
-
Matthews, F.1
Hoigne, D.J.2
Weiser, M.3
Wanner, G.A.4
Regazzoni, P.5
Suhm, N.6
Messmer, P.7
-
5
-
-
33748079472
-
Does computerassisted spine surgery reduce intraoperative radiation doses?
-
Gebhard FT, Kraus MD, Schneider E, Liener UC, Kinzl L, Arand M (2027) Does computerassisted spine surgery reduce intraoperative radiation doses? Spine 31(17):2024–2006
-
Spine
, vol.31
, Issue.17
, pp. 2006-2024
-
-
Gebhard, F.T.1
Kraus, M.D.2
Schneider, E.3
Liener, U.C.4
Kinzl, L.5
Arand, M.6
-
6
-
-
84864367875
-
Screw placement for acetabular fractures: which navigation modality (2-dimensional vs.3-dimensional) should be used? An experimental study
-
Gras F, Marintschev I, Klos K, Mückley T, Hofmann GO, Kahler DM (2012) Screw placement for acetabular fractures: which navigation modality (2-dimensional vs.3-dimensional) should be used? An experimental study. J Orthop Trauma 26(8):466–473
-
(2012)
J Orthop Trauma
, vol.26
, Issue.8
, pp. 466-473
-
-
Gras, F.1
Marintschev, I.2
Klos, K.3
Mückley, T.4
Hofmann, G.O.5
Kahler, D.M.6
-
7
-
-
84986544938
-
Computer aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center
-
Kraus M, Weiskopf J, Dreyhaupt J, Krischak G, Gebhard F (2015) Computer aided surgery does not increase the accuracy of dorsal pedicle screw placement in the thoracic and lumbar spine: a retrospective analysis of 2,003 pedicle screws in a level I trauma center. Global Spine J 5(2):93
-
(2015)
Global Spine J
, vol.5
, Issue.2
, pp. 93
-
-
Kraus, M.1
Weiskopf, J.2
Dreyhaupt, J.3
Krischak, G.4
Gebhard, F.5
-
8
-
-
84875827329
-
Surgeons blinded by enhanced navigation: the effect of augmented reality on attention
-
Dixon BJ, Daly MJ, Chan H et al (2013) Surgeons blinded by enhanced navigation: the effect of augmented reality on attention. Surg Endosc 27:454. https://doi.org/10.1007/s00464-012-2457-3
-
(2013)
Surg Endosc
, vol.27
, pp. 454
-
-
Dixon, B.J.1
Daly, M.J.2
Chan, H.3
-
9
-
-
2942558735
-
Potential pitfalls of computer aided orthopedic surgery
-
Langlotz F (2004) Potential pitfalls of computer aided orthopedic surgery. Injury 35(1):17–23
-
(2004)
Injury
, vol.35
, Issue.1
, pp. 17-23
-
-
Langlotz, F.1
-
10
-
-
80052273854
-
Development and validation of a surgical workload measure: the Surgery Task Load Index (SURG-TLX)
-
Wilson MR, Poolton JM, Malhotra N, Ngo K, Bright E, Masters RSW (2011) Development and validation of a surgical workload measure: the Surgery Task Load Index (SURG-TLX). World J Surg 35(9):1961–1969. https://doi.org/10.1007/s00268-011-1141-4
-
(2011)
World J Surg
, vol.35
, Issue.9
, pp. 1961-1969
-
-
Wilson, M.R.1
Poolton, J.M.2
Malhotra, N.3
Ngo, K.4
Bright, E.5
Masters, R.S.W.6
|