ICP monitoring by open extraventricular drainage: Common practice but not suitable for advanced neuromonitoring and prone to false negativity

Author keywords

Cerebral autoregulation; Extraventricular drainage; ICP monitoring; Intraparenchymal ICP probe; Probe

Indexed keywords

ADULT; ARTERIAL PRESSURE; BRAIN PERFUSION; CEREBROSPINAL FLUID DRAINAGE; CLINICAL ARTICLE; FEMALE; HUMAN; INTERMETHOD COMPARISON; INTRACRANIAL PRESSURE; INTRACRANIAL PRESSURE MONITORING; MALE; MIDDLE AGED; NEUROLOGICAL INTENSIVE CARE UNIT; NEUROMONITORING; RETROSPECTIVE STUDY; SOFTWARE; VENTRICULOSTOMY; BRAIN CIRCULATION; BRAIN VENTRICLE HEMORRHAGE; FALSE NEGATIVE RESULT; HOMEOSTASIS; PATHOPHYSIOLOGY; PHYSIOLOGIC MONITORING; PHYSIOLOGY; PROCEDURES; REPRODUCIBILITY; SUBARACHNOID HEMORRHAGE;

EID: 85042915602     PISSN: 00651419     EISSN: 21978395     Source Type: Book Series    
DOI: 10.1007/978-3-319-65798-1_55     Document Type: Chapter
Times cited : (19)

References (16)
  • 2
    • 33947497488 scopus 로고    scopus 로고
    • Continuous monitoring of cerebrovascular autoregulation after subarachnoid hemorrhage by brain tissue oxygen pressure reactivity and its relation to delayed cerebral infarction
    • Jaeger M, Schuhmann MU, Soehle M, Nagel C, Meixensberger J. Continuous monitoring of cerebrovascular autoregulation after subarachnoid hemorrhage by brain tissue oxygen pressure reactivity and its relation to delayed cerebral infarction. Stroke. 2007;38(3):981–6.
    • (2007) Stroke , vol.38 , Issue.3 , pp. 981-986
    • Jaeger, M.1    Schuhmann, M.U.2    Soehle, M.3    Nagel, C.4    Meixensberger, J.5
  • 3
    • 84924970189 scopus 로고    scopus 로고
    • Consensus summary statement of the international multidisciplinary consensus conference on multimodality monitoring in neurocritical care: A statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive C
    • Le Roux P, Menon DK, Citerio G, et al. Consensus summary statement of the international multidisciplinary consensus conference on multimodality monitoring in neurocritical care: a statement for healthcare professionals from the Neurocritical Care Society and the European Society of Intensive C. Neurocrit Care. 2014;21(Suppl 2):S1–26.
    • (2014) Neurocrit Care , vol.21 , pp. S1-S26
    • Le Roux, P.1    Menon, D.K.2    Citerio, G.3
  • 4
    • 58149461545 scopus 로고    scopus 로고
    • Multicenter clinical assessment of the raumedic neurovent-P intracranial pressure sensor: A report by the BrainIT group
    • Citerio G, Piper I, Chambers IR, Galli D, Enblad P, Kiening K, Ragauskas A, Sahuquillo J, Gregson B, BrainIT Group. Multicenter clinical assessment of the raumedic neurovent-P intracranial pressure sensor: a report by the BrainIT group. Neurosurgery. 2008;63(6):1152–8. discussion 1158
    • (2008) Neurosurgery , vol.63 , Issue.6 , pp. 1152-1158
    • Citerio, G.1    Piper, I.2    Chambers, I.R.3    Galli, D.4    Enblad, P.5    Kiening, K.6    Ragauskas, A.7    Sahuquillo, J.8    Gregson, B.9
  • 5
    • 0030045391 scopus 로고    scopus 로고
    • Laboratory testing of three intracranial pressure microtransducers: Technical report
    • Czosnyka M, Czosnyka Z, Pickard JD. Laboratory testing of three intracranial pressure microtransducers: technical report. Neurosurgery. 1996;38(1):219–24.
    • (1996) Neurosurgery , vol.38 , Issue.1 , pp. 219-224
    • Czosnyka, M.1    Czosnyka, Z.2    Pickard, J.D.3
  • 6
    • 0034773630 scopus 로고    scopus 로고
    • The Camino intracranial pressure sensor: Is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies
    • discussion 1164–5
    • Piper I, Barnes A, Smith D, Dunn L. The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies. Neurosurgery. 2001;49(5):1158–64. discussion 1164–5
    • (2001) Neurosurgery , vol.49 , Issue.5 , pp. 1158-1164
    • Piper, I.1    Barnes, A.2    Smith, D.3    Dunn, L.4
  • 7
    • 0345487539 scopus 로고    scopus 로고
    • Reliability of intraventricular pressure measurement with fiberoptic or solid-state transducers: Avoidance of a methodological error
    • discussion 79–80
    • Raabe A, Stöckel R, Hohrein D, Schöche J. Reliability of intraventricular pressure measurement with fiberoptic or solid-state transducers: avoidance of a methodological error. Neurosurgery. 1998;42(1):74–9. discussion 79–80
    • (1998) Neurosurgery , vol.42 , Issue.1 , pp. 74-79
    • Raabe, A.1    Stöckel, R.2    Hohrein, D.3    Schöche, J.4
  • 8
    • 84953252113 scopus 로고    scopus 로고
    • Comparison of complications in patients receiving different types of intracranial pressure monitoring: A retrospective study in a single center in Switzerland
    • Dimitriou J, Levivier M, Gugliotta M. Comparison of complications in patients receiving different types of intracranial pressure monitoring: a retrospective study in a single center in Switzerland. World Neurosurg. 2016;89:641–6.
    • (2016) World Neurosurg , vol.89 , pp. 641-646
    • Dimitriou, J.1    Levivier, M.2    Gugliotta, M.3
  • 10
    • 33748617576 scopus 로고    scopus 로고
    • Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters
    • Birch AA, Eynon CA, Schley D. Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters. Neurocrit Care. 2006;5(1):51–4.
    • (2006) Neurocrit Care , vol.5 , Issue.1 , pp. 51-54
    • Birch, A.A.1    Eynon, C.A.2    Schley, D.3
  • 11
    • 83155175252 scopus 로고    scopus 로고
    • An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury
    • Vender J, Waller J, Dhandapani K, McDonnell D. An evaluation and comparison of intraventricular, intraparenchymal, and fluid-coupled techniques for intracranial pressure monitoring in patients with severe traumatic brain injury. J Clin Monit Comput. 2011;25(4):231–6.
    • (2011) J Clin Monit Comput , vol.25 , Issue.4 , pp. 231-236
    • Vender, J.1    Waller, J.2    Dhandapani, K.3    McDonnell, D.4
  • 12
    • 0024566024 scopus 로고
    • Erroneous measurement of intracranial pressure caused by simultaneous ventricular drainage: A hydrodynamic model study
    • Wilkinson HA, Yarzebski J, Wilkinson EC, Anderson FA. Erroneous measurement of intracranial pressure caused by simultaneous ventricular drainage: a hydrodynamic model study. Neurosurgery. 1989;24(3):348–54.
    • (1989) Neurosurgery , vol.24 , Issue.3 , pp. 348-354
    • Wilkinson, H.A.1    Yarzebski, J.2    Wilkinson, E.C.3    Anderson, F.A.4
  • 13
    • 84961212278 scopus 로고    scopus 로고
    • The effects of ventricular drainage on the intracranial pressure signal and the pressure reactivity index
    • Howells T, Johnson U, McKelvey T, Ronne-Engström E, Enblad P. The effects of ventricular drainage on the intracranial pressure signal and the pressure reactivity index. J Clin Monit Comput. 2016;31(2):469–78. https://doi.org/10.1007/s10877-016-9863-3.
    • (2016) J Clin Monit Comput , vol.31 , Issue.2 , pp. 469-478
    • Howells, T.1    Johnson, U.2    McKelvey, T.3    Ronne-Engström, E.4    Enblad, P.5
  • 14
    • 0030927177 scopus 로고    scopus 로고
    • Continuous assessment of the cerebral vasomotor reactivity in head injury
    • discussion 17–9
    • Czosnyka M, Smielewski P, Kirkpatrick P, Laing RJ, Menon D, Pickard JD. Continuous assessment of the cerebral vasomotor reactivity in head injury. Neurosurgery. 1997;41(1):11–7. discussion 17–9
    • (1997) Neurosurgery , vol.41 , Issue.1 , pp. 11-17
    • Czosnyka, M.1    Smielewski, P.2    Kirkpatrick, P.3    Laing, R.J.4    Menon, D.5    Pickard, J.D.6
  • 15
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet (London). 1986;1(8476):307–10.
    • (1986) Lancet (London) , vol.1 , Issue.8476 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 16
    • 0034885626 scopus 로고    scopus 로고
    • Clinical comparison of the Spiegelberg parenchymal transducer and ventricular fluid pressure
    • Chambers IR, Siddique MS, Banister K, Mendelow AD. Clinical comparison of the Spiegelberg parenchymal transducer and ventricular fluid pressure. J Neurol Neurosurg Psychiatry. 2001;71(3):383–5.
    • (2001) J Neurol Neurosurg Psychiatry , vol.71 , Issue.3 , pp. 383-385
    • Chambers, I.R.1    Siddique, M.S.2    Banister, K.3    Mendelow, A.D.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.