메뉴 건너뛰기




Volumn 24, Issue , 2018, Pages 78-81

Reliability of ultrasonographic arm muscle thickness measurement by various levels of health care providers in ICU

Author keywords

Arm muscles; Critical illness; Reliability; Sepsis; Ultrasonography

Indexed keywords

ADULT; APACHE; ARM MUSCLE; ARTICLE; CLINICAL ARTICLE; CROSS-SECTIONAL STUDY; ECHOGRAPHY; FEMALE; HEALTH CARE PERSONNEL; HUMAN; INTENSIVE CARE UNIT; MALE; MIDDLE AGED; MUSCLE THICKNESS; OBSERVATIONAL STUDY; RELIABILITY; SEPSIS; SIMPLIFIED ACUTE PHYSIOLOGY SCORE; AGED; ARM; DIAGNOSTIC IMAGING; OBSERVER VARIATION; PATHOPHYSIOLOGY; POINT OF CARE TESTING; PREDICTIVE VALUE; REPRODUCIBILITY;

EID: 85042058786     PISSN: 24054577     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.clnesp.2018.01.009     Document Type: Article
Times cited : (15)

References (21)
  • 1
    • 84994430617 scopus 로고    scopus 로고
    • ICU-acquired weakness
    • Jolley, S.E., Bunnell, A.E., Hough, C.L., ICU-acquired weakness. Chest 150:5 (2016), 1129–1140.
    • (2016) Chest , vol.150 , Issue.5 , pp. 1129-1140
    • Jolley, S.E.1    Bunnell, A.E.2    Hough, C.L.3
  • 2
    • 13744249236 scopus 로고    scopus 로고
    • Neuromuscular weakness in critically ill
    • Khilnani, G.C., Bansal, R., Neuromuscular weakness in critically ill. J Assoc Physicians India 52 (2004), 131–136.
    • (2004) J Assoc Physicians India , vol.52 , pp. 131-136
    • Khilnani, G.C.1    Bansal, R.2
  • 3
    • 84899094626 scopus 로고    scopus 로고
    • ICU-acquired weakness and recovery from critical illness
    • Kress, J.P., Hall, J.B., ICU-acquired weakness and recovery from critical illness. N Engl J Med 370:17 (2014), 1626–1635.
    • (2014) N Engl J Med , vol.370 , Issue.17 , pp. 1626-1635
    • Kress, J.P.1    Hall, J.B.2
  • 4
    • 84937511901 scopus 로고    scopus 로고
    • Intensive care unit-related generalized neuromuscular weakness due to critical illness polyneuropathy/myopathy in critically ill patients
    • Apostolakis, E., Papakonstantinou, N.A., Baikoussis, N.G., Papadopoulos, G., Intensive care unit-related generalized neuromuscular weakness due to critical illness polyneuropathy/myopathy in critically ill patients. J Anesth 29:1 (2015), 112–121.
    • (2015) J Anesth , vol.29 , Issue.1 , pp. 112-121
    • Apostolakis, E.1    Papakonstantinou, N.A.2    Baikoussis, N.G.3    Papadopoulos, G.4
  • 6
    • 70350517765 scopus 로고    scopus 로고
    • A framework for diagnosing and classifying intensive care unit-acquired weakness
    • Stevens, R.D., Marshall, S.A., Cornblath, D.R., Hoke, A., Needham, D.M., de Jonghe, B., et al. A framework for diagnosing and classifying intensive care unit-acquired weakness. Crit Care Med 37:10 Suppl (2009), S299–S308.
    • (2009) Crit Care Med , vol.37 , Issue.10 , pp. S299-S308
    • Stevens, R.D.1    Marshall, S.A.2    Cornblath, D.R.3    Hoke, A.4    Needham, D.M.5    de Jonghe, B.6
  • 7
    • 0029103190 scopus 로고
    • Muscle thickness, measured with ultrasound, may be an indicator of lean tissue wasting in multiple organ failure in the presence of edema
    • Campbell, I.T., Watt, T., Withers, D., England, R., Sukumar, S., Keegan, M.A., et al. Muscle thickness, measured with ultrasound, may be an indicator of lean tissue wasting in multiple organ failure in the presence of edema. Am J Clin Nutr 62:3 (1995), 533–539.
    • (1995) Am J Clin Nutr , vol.62 , Issue.3 , pp. 533-539
    • Campbell, I.T.1    Watt, T.2    Withers, D.3    England, R.4    Sukumar, S.5    Keegan, M.A.6
  • 9
    • 41349122451 scopus 로고    scopus 로고
    • Muscle wasting in intensive care patients: ultrasound observation of the M. quadriceps femoris muscle layer
    • Gruther, W., Benesch, T., Zorn, C., Paternostro-Sluga, T., Quittan, M., Fialka-Moser, V., et al. Muscle wasting in intensive care patients: ultrasound observation of the M. quadriceps femoris muscle layer. J Rehabil Med 40:3 (2008), 185–189.
    • (2008) J Rehabil Med , vol.40 , Issue.3 , pp. 185-189
    • Gruther, W.1    Benesch, T.2    Zorn, C.3    Paternostro-Sluga, T.4    Quittan, M.5    Fialka-Moser, V.6
  • 10
    • 67649213565 scopus 로고    scopus 로고
    • Quantification of muscle volume by echography: comparison with MRI data on subjects in long-term bed rest
    • Arbeille, P., Kerbeci, P., Capri, A., Dannaud, C., Trappe, S.W., Trappe, T.A., Quantification of muscle volume by echography: comparison with MRI data on subjects in long-term bed rest. Ultrasound Med Biol 35:7 (2009), 1092–1097.
    • (2009) Ultrasound Med Biol , vol.35 , Issue.7 , pp. 1092-1097
    • Arbeille, P.1    Kerbeci, P.2    Capri, A.3    Dannaud, C.4    Trappe, S.W.5    Trappe, T.A.6
  • 11
  • 12
    • 85025114271 scopus 로고    scopus 로고
    • Intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians
    • Hadda, V., Khilnani, G.C., Kumar, R., Dhunguna, A., Mittal, S., Khan, M.A., et al. Intra- and inter-observer reliability of quadriceps muscle thickness measured with bedside ultrasonography by critical care physicians. Indian J Crit Care Med 21:7 (2017), 448–452.
    • (2017) Indian J Crit Care Med , vol.21 , Issue.7 , pp. 448-452
    • Hadda, V.1    Khilnani, G.C.2    Kumar, R.3    Dhunguna, A.4    Mittal, S.5    Khan, M.A.6
  • 13
    • 85025112003 scopus 로고    scopus 로고
    • Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians
    • Hadda, V., Kumar, R., Dhungana, A., Khan, M.A., Madan, K., Khilnani, G.C., Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians. J Postgrad Med 63:3 (2017), 157–161.
    • (2017) J Postgrad Med , vol.63 , Issue.3 , pp. 157-161
    • Hadda, V.1    Kumar, R.2    Dhungana, A.3    Khan, M.A.4    Madan, K.5    Khilnani, G.C.6
  • 14
    • 80053309826 scopus 로고    scopus 로고
    • Diaphragm and peripheral muscle thickness on ultrasound: intra-rater reliability and variability of a methodology using non-standard recumbent positions
    • Baldwin, C.E., Paratz, J.D., Bersten, A.D., Diaphragm and peripheral muscle thickness on ultrasound: intra-rater reliability and variability of a methodology using non-standard recumbent positions. Respirology 16:7 (2011), 1136–1143.
    • (2011) Respirology , vol.16 , Issue.7 , pp. 1136-1143
    • Baldwin, C.E.1    Paratz, J.D.2    Bersten, A.D.3
  • 15
    • 73349118174 scopus 로고    scopus 로고
    • Ethical principles for medical research involving human subjects
    • Declaration of Helsinki, Ethical principles for medical research involving human subjects. J Indian Med Assoc 107:6 (2009), 403–405.
    • (2009) J Indian Med Assoc , vol.107 , Issue.6 , pp. 403-405
    • Declaration of Helsinki1
  • 16
    • 84888610885 scopus 로고    scopus 로고
    • World Medical Association declaration of Helsinki: ethical principles for medical research involving human subjects
    • World Medical Association declaration of Helsinki: ethical principles for medical research involving human subjects. JAMA 310:20 (2013), 2191–2194.
    • (2013) JAMA , vol.310 , Issue.20 , pp. 2191-2194
  • 17
    • 1642527377 scopus 로고    scopus 로고
    • Muscle wasting and energy balance in critical illness
    • Reid, C.L., Campbell, I.T., Little, R.A., Muscle wasting and energy balance in critical illness. Clin Nutr 23:2 (2004), 273–280.
    • (2004) Clin Nutr , vol.23 , Issue.2 , pp. 273-280
    • Reid, C.L.1    Campbell, I.T.2    Little, R.A.3
  • 18
    • 84941315884 scopus 로고    scopus 로고
    • Ultrasonography in the intensive care setting can be used to detect changes in the quality and quantity of muscle and is related to muscle strength and function
    • Parry, S.M., El-Ansary, D., Cartwright, M.S., Sarwal, A., Berney, S., Koopman, R., et al. Ultrasonography in the intensive care setting can be used to detect changes in the quality and quantity of muscle and is related to muscle strength and function. J Crit Care 30:5 (2015), 1151.e9–1151.e14.
    • (2015) J Crit Care , vol.30 , Issue.5 , pp. 1151.e9-1151.e14
    • Parry, S.M.1    El-Ansary, D.2    Cartwright, M.S.3    Sarwal, A.4    Berney, S.5    Koopman, R.6
  • 19
    • 84982082427 scopus 로고    scopus 로고
    • An analysis of reliability and accuracy of muscle thickness ultrasonography in critically ill children and adults
    • Fivez, T., Hendrickx, A., Van Herpe, T., Vlasselaers, D., Desmet, L., Van den Berghe, G., et al. An analysis of reliability and accuracy of muscle thickness ultrasonography in critically ill children and adults. JPEN J Parenter Enteral Nutr 40:7 (2016), 944–949.
    • (2016) JPEN J Parenter Enteral Nutr , vol.40 , Issue.7 , pp. 944-949
    • Fivez, T.1    Hendrickx, A.2    Van Herpe, T.3    Vlasselaers, D.4    Desmet, L.5    Van den Berghe, G.6
  • 20
    • 85008918097 scopus 로고    scopus 로고
    • Reliability of bedside ultrasound for measurement of quadriceps muscle thickness in critically ill patients with acute kidney injury
    • Sabatino, A., Regolisti, G., Bozzoli, L., Fani, F., Antoniotti, R., Maggiore, U., et al. Reliability of bedside ultrasound for measurement of quadriceps muscle thickness in critically ill patients with acute kidney injury. Clin Nutr 36:6 (2017), 1710–1715.
    • (2017) Clin Nutr , vol.36 , Issue.6 , pp. 1710-1715
    • Sabatino, A.1    Regolisti, G.2    Bozzoli, L.3    Fani, F.4    Antoniotti, R.5    Maggiore, U.6
  • 21


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.