메뉴 건너뛰기




Volumn 6, Issue 3, 2017, Pages 212-217

Editor’s Choice-Rule-in of acute myocardial infarction: Focus on troponin

Author keywords

Acute myocardial infarction; diagnosis; rule in; troponin

Indexed keywords

BIOLOGICAL MARKER; TROPONIN; TROPONIN I; TROPONIN T;

EID: 85034977508     PISSN: 20488726     EISSN: 20488734     Source Type: Journal    
DOI: 10.1177/2048872616653228     Document Type: Article
Times cited : (31)

References (24)
  • 1
    • 84856070725 scopus 로고    scopus 로고
    • Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome
    • Mueller M, Biener M, Vafaie M. Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome. Clin Chem 2012; 58: 209–218.
    • (2012) Clin Chem , vol.58 , pp. 209-218
    • Mueller, M.1    Biener, M.2    Vafaie, M.3
  • 2
    • 67649415216 scopus 로고    scopus 로고
    • Frequency of elevated troponin I and diagnosis of acute myocardial infarction
    • Javed U, Aftab W, Ambrose JA. Frequency of elevated troponin I and diagnosis of acute myocardial infarction. Am J Cardiol 2009; 104: 9–13.
    • (2009) Am J Cardiol , vol.104 , pp. 9-13
    • Javed, U.1    Aftab, W.2    Ambrose, J.A.3
  • 3
    • 84874941217 scopus 로고    scopus 로고
    • Chief complaints in medical emergencies: do they relate to underlying disease and outcome? The Charite Emergency Medicine Study (CHARITEM)
    • Mockel M, Searle J, Muller R. Chief complaints in medical emergencies: do they relate to underlying disease and outcome? The Charite Emergency Medicine Study (CHARITEM). Eur J Emerg Med 2013; 20: 103–108.
    • (2013) Eur J Emerg Med , vol.20 , pp. 103-108
    • Mockel, M.1    Searle, J.2    Muller, R.3
  • 4
    • 84856068587 scopus 로고    scopus 로고
    • Analytical characteristics of high-sensitivity cardiac troponin assays
    • Apple FS, Collinson PO, IFCC Task Force on Clinical Applications of Cardiac Biomarkers. Analytical characteristics of high-sensitivity cardiac troponin assays. Clin Chem 2012; 58: 54–61.
    • (2012) Clin Chem , vol.58 , pp. 54-61
    • Apple, F.S.1    Collinson, P.O.2
  • 5
    • 84867740025 scopus 로고    scopus 로고
    • Third universal definition of myocardial infarction
    • Thygesen K, Alpert JS, Jaffe AS. Third universal definition of myocardial infarction. Eur Heart J 2012; 33: 2551–2567.
    • (2012) Eur Heart J , vol.33 , pp. 2551-2567
    • Thygesen, K.1    Alpert, J.S.2    Jaffe, A.S.3
  • 6
    • 84971619896 scopus 로고    scopus 로고
    • 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC)
    • Roffi M, Patrono C, Collet JP. 2015 ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: Task Force for the Management of Acute Coronary Syndromes in Patients Presenting without Persistent ST-Segment Elevation of the European Society of Cardiology (ESC). Eur Heart J 2016; 37: 267–315.
    • (2016) Eur Heart J , vol.37 , pp. 267-315
    • Roffi, M.1    Patrono, C.2    Collet, J.P.3
  • 7
    • 84862580045 scopus 로고    scopus 로고
    • Delta changes for optimizing clinical specificity and 60-day risk of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome utilizing the ADVIA Centaur TnI-Ultra assay
    • Apple FS, Smith SW, Pearce LA. Delta changes for optimizing clinical specificity and 60-day risk of adverse events in patients presenting with symptoms suggestive of acute coronary syndrome utilizing the ADVIA Centaur TnI-Ultra assay. Clin Biochem 2012; 45: 711–713.
    • (2012) Clin Biochem , vol.45 , pp. 711-713
    • Apple, F.S.1    Smith, S.W.2    Pearce, L.A.3
  • 8
    • 77950558991 scopus 로고    scopus 로고
    • High-sensitivity cardiac troponin T for early prediction of evolving non-ST-segment elevation myocardial infarction in patients with suspected acute coronary syndrome and negative troponin results on admission
    • Giannitsis E, Becker M, Kurz K. High-sensitivity cardiac troponin T for early prediction of evolving non-ST-segment elevation myocardial infarction in patients with suspected acute coronary syndrome and negative troponin results on admission. Clin Chem 2010; 56: 642–650.
    • (2010) Clin Chem , vol.56 , pp. 642-650
    • Giannitsis, E.1    Becker, M.2    Kurz, K.3
  • 9
    • 84555195443 scopus 로고    scopus 로고
    • Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction
    • Keller T, Zeller T, Ojeda F. Serial changes in highly sensitive troponin I assay and early diagnosis of myocardial infarction. JAMA 2011; 306: 2684–2693.
    • (2011) JAMA , vol.306 , pp. 2684-2693
    • Keller, T.1    Zeller, T.2    Ojeda, F.3
  • 10
    • 84866103717 scopus 로고    scopus 로고
    • One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
    • Reichlin T, Schindler C, Drexler B. One-hour rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Arch Intern Med 2012; 172: 1211–1218.
    • (2012) Arch Intern Med , vol.172 , pp. 1211-1218
    • Reichlin, T.1    Schindler, C.2    Drexler, B.3
  • 11
    • 84965094182 scopus 로고    scopus 로고
    • In search for the Holy Grail: suggestions for studies to define delta changes to diagnose or exclude acute myocardial infarction: a position paper from the study group on biomarkers of the Acute Cardiovascular Care Association
    • Jaffe AS, Moeckel M, Giannitsis E. In search for the Holy Grail: suggestions for studies to define delta changes to diagnose or exclude acute myocardial infarction: a position paper from the study group on biomarkers of the Acute Cardiovascular Care Association. Eur Heart J Acute Cardiovasc Care 2014; 3: 313–316.
    • (2014) Eur Heart J Acute Cardiovasc Care , vol.3 , pp. 313-316
    • Jaffe, A.S.1    Moeckel, M.2    Giannitsis, E.3
  • 12
    • 84921770937 scopus 로고    scopus 로고
    • High sensitivity cardiac troponin and the under-diagnosis of myocardial infarction in women: prospective cohort study
    • Shah AS, Griffiths M, Lee KK. High sensitivity cardiac troponin and the under-diagnosis of myocardial infarction in women: prospective cohort study. BMJ 2015; 350: g7873.
    • (2015) BMJ , vol.350 , pp. g7873
    • Shah, A.S.1    Griffiths, M.2    Lee, K.K.3
  • 13
    • 84958981652 scopus 로고    scopus 로고
    • Sex-specific versus overall cut points for a high sensitivity troponin I assay in predicting 1-year outcomes in emergency patients presenting with chest pain
    • Cullen L, Greenslade JH, Carlton EW. Sex-specific versus overall cut points for a high sensitivity troponin I assay in predicting 1-year outcomes in emergency patients presenting with chest pain. Heart 2016; 102: 120–126.
    • (2016) Heart , vol.102 , pp. 120-126
    • Cullen, L.1    Greenslade, J.H.2    Carlton, E.W.3
  • 14
    • 84929323939 scopus 로고    scopus 로고
    • Sex differences of troponin test performance in chest pain patients
    • Slagman A, Searle J, Vollert JO. Sex differences of troponin test performance in chest pain patients. Int J Cardiol 2015; 187: 246–251.
    • (2015) Int J Cardiol , vol.187 , pp. 246-251
    • Slagman, A.1    Searle, J.2    Vollert, J.O.3
  • 15
    • 84868607051 scopus 로고    scopus 로고
    • Effect of older age on diagnostic and prognostic performance of high-sensitivity troponin T in patients presenting to an emergency department
    • Normann J, Mueller M, Biener M. Effect of older age on diagnostic and prognostic performance of high-sensitivity troponin T in patients presenting to an emergency department. Am Heart J 2012; 164: 698–705.
    • (2012) Am Heart J , vol.164 , pp. 698-705
    • Normann, J.1    Mueller, M.2    Biener, M.3
  • 16
    • 84879719914 scopus 로고    scopus 로고
    • Factors influencing the 99th percentile of cardiac troponin I evaluated in community-dwelling individuals at 70 and 75 years of age
    • Eggers KM, Lind L, Venge P. Factors influencing the 99th percentile of cardiac troponin I evaluated in community-dwelling individuals at 70 and 75 years of age. Clin Chem 2013; 59: 1068–1073.
    • (2013) Clin Chem , vol.59 , pp. 1068-1073
    • Eggers, K.M.1    Lind, L.2    Venge, P.3
  • 17
    • 84856158305 scopus 로고    scopus 로고
    • ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC)
    • Hamm CW, Bassand JP, Agewall S. ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation: the Task Force for the management of acute coronary syndromes (ACS) in patients presenting without persistent ST-segment elevation of the European Society of Cardiology (ESC). Eur Heart J 2011; 32: 2999–3054.
    • (2011) Eur Heart J , vol.32 , pp. 2999-3054
    • Hamm, C.W.1    Bassand, J.P.2    Agewall, S.3
  • 18
    • 84860338869 scopus 로고    scopus 로고
    • How to use high-sensitivity cardiac troponins in acute cardiac care
    • Thygesen K, Mair J, Giannitsis E. How to use high-sensitivity cardiac troponins in acute cardiac care. Eur Heart J 2012; 33: 2252–2257.
    • (2012) Eur Heart J , vol.33 , pp. 2252-2257
    • Thygesen, K.1    Mair, J.2    Giannitsis, E.3
  • 19
    • 84937812627 scopus 로고    scopus 로고
    • One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I
    • Rubini Gimenez M, Twerenbold R, Jaeger C. One-hour rule-in and rule-out of acute myocardial infarction using high-sensitivity cardiac troponin I. Am J Med 2015; 128: 861–870.
    • (2015) Am J Med , vol.128 , pp. 861-870
    • Rubini Gimenez, M.1    Twerenbold, R.2    Jaeger, C.3
  • 20
    • 84937547499 scopus 로고    scopus 로고
    • Early rule-out and rule-in of myocardial infarction using sensitive cardiac Troponin I
    • Druey S, Wildi K, Twerenbold R. Early rule-out and rule-in of myocardial infarction using sensitive cardiac Troponin I. Int J Cardiol 2015; 195: 163–170.
    • (2015) Int J Cardiol , vol.195 , pp. 163-170
    • Druey, S.1    Wildi, K.2    Twerenbold, R.3
  • 21
    • 84964696078 scopus 로고    scopus 로고
    • Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay
    • Reichlin T, Twerenbold R, Wildi K. Prospective validation of a 1-hour algorithm to rule-out and rule-in acute myocardial infarction using a high-sensitivity cardiac troponin T assay. CMAJ 2015; 187: E243–E252.
    • (2015) CMAJ , vol.187 , pp. E243-E252
    • Reichlin, T.1    Twerenbold, R.2    Wildi, K.3
  • 22
    • 84930382031 scopus 로고    scopus 로고
    • Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T
    • Reichlin T, Cullen L, Parsonage WA. Two-hour algorithm for triage toward rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin T. Am J Med 2014; 128: 369–379.
    • (2014) Am J Med , vol.128 , pp. 369-379
    • Reichlin, T.1    Cullen, L.2    Parsonage, W.A.3
  • 23
    • 84959272029 scopus 로고    scopus 로고
    • Two-hour algorithm for triage towards rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin I
    • Boeddinghaus J, Reichlin T, Cullen L. Two-hour algorithm for triage towards rule-out and rule-in of acute myocardial infarction using high-sensitivity cardiac troponin I. Clin Chem. 2016; 62: 494–504.
    • (2016) Clin Chem , vol.62 , pp. 494-504
    • Boeddinghaus, J.1    Reichlin, T.2    Cullen, L.3
  • 24
    • 84880586708 scopus 로고    scopus 로고
    • Using high-sensitivity troponin T: the importance of the proper gold standard
    • Santalo M, Martin A, Velilla J. Using high-sensitivity troponin T: the importance of the proper gold standard. Am J Med 2013; 126: 709–717.
    • (2013) Am J Med , vol.126 , pp. 709-717
    • Santalo, M.1    Martin, A.2    Velilla, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.