Volumn 400, Issue 9, 2011, Pages 2871-2880

Investigation of the specificity of Raman spectroscopy in non-invasive blood glucose measurements

Author keywords

Animal model; Causation; Chance correlations; Human subject; Non invasive glucose monitoring; Raman spectroscopy

Indexed keywords

ABSORPTION SPECTROSCOPY; ANIMALS; BLOOD; INFRARED DEVICES; PATIENT MONITORING; PHOTONICS; PHYSIOLOGY; RAMAN SPECTROSCOPY; TISSUE;

EID: 85027952068     PISSN: 16182642     EISSN: 16182650     Source Type: Journal    
DOI: 10.1007/s00216-011-5004-5     Document Type: Article
Times cited : (81)

References (32)
  • 1
    • 0031036953 scopus 로고    scopus 로고
    • 10.2337/diacare.20.3.433 1:STN:280:DyaK2s3gtlyhuw%3D%3D
    • DC Klonoff 1997 Diabetes Care 20 433 437 10.2337/diacare.20.3.433 1:STN:280:DyaK2s3gtlyhuw%3D%3D
    • (1997) Diabetes Care , vol.20 , pp. 433-437
    • Klonoff, D.C.1
  • 4
    • 0033086344 scopus 로고    scopus 로고
    • 10.1089/152091599317639 1:STN:280:DC%2BD3Mvis1KrsA%3D%3D
    • MA Charles 1999 Diab Technol Ther 1 89 96 10.1089/152091599317639 1:STN:280:DC%2BD3Mvis1KrsA%3D%3D
    • (1999) Diab Technol Ther , vol.1 , pp. 89-96
    • Charles, M.A.1
  • 5
    • 6044275963 scopus 로고    scopus 로고
    • Non-invasive glucose measurement technologies: An update from 1999 to the dawn of the new millennium
    • DOI 10.1089/dia.2004.6.660
    • OS Khalil 2004 Diab Technol Ther 6 660 697 10.1089/dia.2004.6.660 1:CAS:528:DC%2BD2cXoslGiur8%3D (Pubitemid 39383073)
    • (2004) Diabetes Technology and Therapeutics , vol.6 , Issue.5 , pp. 660-697
    • Khalil, O.S.1
  • 9
    • 0242269450 scopus 로고    scopus 로고
    • 10.1366/000370203769699090 1:CAS:528:DC%2BD3sXotVSrsL4%3D
    • K Maruo M Tsurugi M Tamura Y Ozaki 2003 Appl Spectrosc 57 1236 1244 10.1366/000370203769699090 1:CAS:528:DC%2BD3sXotVSrsL4%3D
    • (2003) Appl Spectrosc , vol.57 , pp. 1236-1244
    • Maruo, K.1    Tsurugi, M.2    Tamura, M.3    Ozaki, Y.4
  • 13
    • 3042551400 scopus 로고    scopus 로고
    • Multivariate calibration with least-squares support vector machines
    • DOI 10.1021/ac035522m
    • U Thissen B Ustun WJ Melssen LMC Buydens 2004 Anal Chem 76 3099 3105 10.1021/ac035522m 1:CAS:528:DC%2BD2cXjs1ensr0%3D (Pubitemid 38715701)
    • (2004) Analytical Chemistry , vol.76 , Issue.11 , pp. 3099-3105
    • Thissen, U.1    Ustun, B.2    Melsseit, W.J.3    Buydens, L.M.C.4
  • 14
    • 0030025192 scopus 로고    scopus 로고
    • Non-invasive glucose monitoring
    • DOI 10.1016/S0958-1669(96)80093-0
    • MA Arnold 1996 Curr Opin Biotechnol 7 46 49 10.1016/S0958-1669(96)80093-0 1:CAS:528:DyaK28XhtlahsbY%3D (Pubitemid 26066586)
    • (1996) Current Opinion in Biotechnology , vol.7 , Issue.1 , pp. 46-49
    • Arnold, M.A.1
  • 15
    • 23044445368 scopus 로고    scopus 로고
    • Chance correlation in non-invasive glucose measurement using near-infrared spectroscopy
    • DOI 10.1088/0022-3727/38/15/020, PII S0022372705911832
    • R Liu W Chen X Gu RK Wang K Xu 2005 J Phys D Appl Phys 38 2675 2681 10.1088/0022-3727/38/15/020 1:CAS:528:DC%2BD2MXovFSiu78%3D (Pubitemid 41067758)
    • (2005) Journal of Physics D: Applied Physics , vol.38 , Issue.15 , pp. 2675-2681
    • Liu, R.1    Chen, W.2    Gu, X.3    Wang, R.K.4    Xu, K.5
  • 20
  • 24
    • 31144451528 scopus 로고    scopus 로고
    • Next step of non-invasive glucose monitor by NIR technique from the well controlled measuring condition and results
    • DOI 10.1007/s11082-005-4201-x
    • R Liu B Deng W Chen K Xu 2005 Opt Quant Electron 37 1305 1317 10.1007/s11082-005-4201-x (Pubitemid 43130615)
    • (2005) Optical and Quantum Electronics , vol.37 , Issue.13-15 , pp. 1305-1317
    • Liu, R.1    Deng, B.2    Chen, W.3    Xu, K.4
  • 25
    • 0032065545 scopus 로고    scopus 로고
    • 10.1021/ac9710801 1:CAS:528:DyaK1cXislShsrw%3D
    • MA Arnold JJ Burmeister GW Small 1998 Anal Chem 70 1773 1781 10.1021/ac9710801 1:CAS:528:DyaK1cXislShsrw%3D
    • (1998) Anal Chem , vol.70 , pp. 1773-1781
    • Arnold, M.A.1    Burmeister, J.J.2    Small, G.W.3
  • 30
    • 34247544462 scopus 로고    scopus 로고
    • Chemical concentration measurement in blood serum and urine samples using liquid-core optical fiber Raman spectroscopy
    • DOI 10.1364/AO.46.001726
    • D Qi AJ Berger 2007 Appl Opt 46 1726 1734 10.1364/AO.46.001726 1:CAS:528:DC%2BD2sXks1alu74%3D (Pubitemid 46659539)
    • (2007) Applied Optics , vol.46 , Issue.10 , pp. 1726-1734
    • Qi, D.1    Berger, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.