Effect of photobleaching on calibration model development in biological Raman spectroscopy

Author keywords

Blood glucose monitoring; chemometrics; photobleaching; Raman spectroscopy; shifted subtracted Raman spectroscopy; tissue fluorescence

Indexed keywords

ANALYTE CONCENTRATION; BIOLOGICAL STUDIES; BLOOD GLUCOSE MONITORING; CALIBRATION ALGORITHM; CALIBRATION MODEL; CHEMOMETRICS; DATA SETS; DELETERIOUS EFFECTS; FLUORESCENCE LEVEL; FUNCTIONAL MODEL; GLUCOSE DETECTION; NUMERICAL SIMULATION; PREDICTION ACCURACY; PREDICTION ERRORS; SHIFTED SUBTRACTED RAMAN SPECTROSCOPY; TISSUE MODELS; TRANSCUTANEOUS;

EID: 78651333706     PISSN: 10833668     EISSN: 15602281     Source Type: Journal    
DOI: 10.1117/1.3520131     Document Type: Article
Times cited : (29)

References (41)
  • 2
    • 23844497083 scopus 로고    scopus 로고
    • Determination of glucose in human aqueous humor using Raman spectroscopy and designed-solution calibration
    • DOI 10.1366/0003702054615133
    • C. C. Pelletier, J. L. Lambert, and M. Borchert, " Determination of glucose in human aqueous humor using Raman spectroscopy and designed-solution calibration.," Appl. Spectrosc. 59, 1024-1031 (2005). 10.1366/ 0003702054615133 (Pubitemid 41164580)
    • (2005) Applied Spectroscopy , vol.59 , Issue.8 , pp. 1024-1031
    • Pelletier, C.C.1    Lambert, J.L.2    Borchert, M.3
  • 3
    • 0031816932 scopus 로고    scopus 로고
    • Bloodless glucose measurements
    • J. N. Roe and B. R. Smoller, " Bloodless glucose measurements.," Crit. Rev. Ther. Drug. 15 (3), 199-241 (1998).
    • (1998) Crit. Rev. Ther. Drug. , vol.15 , Issue.3 , pp. 199-241
    • Roe, J.N.1    Smoller, B.R.2
  • 5
    • 24144442925 scopus 로고    scopus 로고
    • Effect of hemoglobin concentration variation on the accuracy and precision of glucose analysis using tissue modulated, noninvasive, in vivo Raman spectroscopy of human blood: A small clinical study
    • 03.
    • J. Chaiken, W. Finney, P. E. Knudson, R. S. Weinstock, M. Khan, R. J. Bussjager, D. Hagrman, P. Hagrman, Y. W. Zhao, C. M. Peterson, and K. Peterson, " Effect of hemoglobin concentration variation on the accuracy and precision of glucose analysis using tissue modulated, noninvasive, in vivo Raman spectroscopy of human blood: a small clinical study.," J. Biomed. Opt. 10 (3), 03 1111 (2005).
    • (2005) J. Biomed. Opt. , vol.10 , Issue.3 , pp. 1111
    • Chaiken, J.1    Finney, W.2    Knudson, P.E.3    Weinstock, R.S.4    Khan, M.5    Bussjager, R.J.6    Hagrman, D.7    Hagrman, P.8    Zhao, Y.W.9    Peterson, C.M.10    Peterson, K.11
  • 6
    • 66349130707 scopus 로고    scopus 로고
    • Turbidity-corrected Raman spectroscopy for blood analyte detection
    • 10.1021/ac8025509
    • I. Barman, G. P. Singh, R. R. Dasari, and M. S. Feld, " Turbidity-corrected Raman spectroscopy for blood analyte detection.," Anal. Chem. 81 (11), 4233-4240 (2009). 10.1021/ac8025509
    • (2009) Anal. Chem. , vol.81 , Issue.11 , pp. 4233-4240
    • Barman, I.1    Singh, G.P.2    Dasari, R.R.3    Feld, M.S.4
  • 7
    • 0036085752 scopus 로고    scopus 로고
    • Fluorescence background suppression in Raman spectroscopy using combined Kerr gated and shifted excitation Raman difference techniques
    • 10.1002/jrs.840
    • P. Matousek, M. Towrie, and A. W. Parker, " Fluorescence background suppression in Raman spectroscopy using combined Kerr gated and shifted excitation Raman difference techniques.," J. Raman Spectrosc. 33 (4), 238-242 (2002). 10.1002/jrs.840
    • (2002) J. Raman Spectrosc. , vol.33 , Issue.4 , pp. 238-242
    • Matousek, P.1    Towrie, M.2    Parker, A.W.3
  • 9
    • 63149173251 scopus 로고    scopus 로고
    • Standards of medical care in diabetes
    • American Diabetes Association, ",".
    • American Diabetes Association, " Standards of medical care in diabetes.," Diabetes Care 32, S13-S61 (2009).
    • (2009) Diabetes Care , vol.32
  • 10
    • 0018520840 scopus 로고
    • Glucose clamp technique: A method for quantifying insulin secretion and resistance
    • R. A. DeFronzo, J. D. Tobin, and R. Andres, " Glucose clamp technique: a method for quantifying insulin secretion and resistance.," Am. J. Physiol. Gastrointest. Liver Physiol. 237 (3), G214-G233 (1979).
    • (1979) Am. J. Physiol. Gastrointest. Liver Physiol. , vol.237 , Issue.3
    • Defronzo, R.A.1    Tobin, J.D.2    Andres, R.3
  • 13
    • 0032065545 scopus 로고    scopus 로고
    • Phantom glucose calibration models from simulated noninvasive human near-infrared spectra
    • 10.1021/ac9710801
    • M. A. Arnold, J. J. Burmeister, and G. W. Small, " Phantom glucose calibration models from simulated noninvasive human near-infrared spectra.," Anal. Chem. 70 (9), 1773-1781 (1998). 10.1021/ac9710801
    • (1998) Anal. Chem. , vol.70 , Issue.9 , pp. 1773-1781
    • Arnold, M.A.1    Burmeister, J.J.2    Small, G.W.3
  • 14
    • 23044445368 scopus 로고    scopus 로고
    • Chance correlation in non-invasive glucose measurement using near-infrared spectroscopy
    • DOI 10.1088/0022-3727/38/15/020, PII S0022372705911832
    • R. Liu, W. Chen, X. Gu, R. K. Wang, and K. Xu, " Chance correlation in non-invasive glucose measurement using near-infrared spectroscopy.," J. Phys. D: Appl. Phys. 38, 2675-2681 (2005). 10.1088/0022-3727/38/15/020 (Pubitemid 41067758)
    • (2005) Journal of Physics D: Applied Physics , vol.38 , Issue.15 , pp. 2675-2681
    • Liu, R.1    Chen, W.2    Gu, X.3    Wang, R.K.4    Xu, K.5
  • 15
    • 0015435196 scopus 로고
    • Reduction of fluorescence background in Raman spectra by the pulsed Raman technique
    • 10.1364/JOSA.62.001297
    • P. P. Yaney, " Reduction of fluorescence background in Raman spectra by the pulsed Raman technique.," J. Opt. Soc. Am. 62 (11), 1297-1303 (1972). 10.1364/JOSA.62.001297
    • (1972) J. Opt. Soc. Am. , vol.62 , Issue.11 , pp. 1297-1303
    • Yaney, P.P.1
  • 16
    • 0001741635 scopus 로고
    • Fluorescence rejection in Raman spectroscopy by shifted-spectra, edge detection, and FFT filtering techniques
    • 10.1366/0003702953964039
    • P. A. Mosier-Boss, S. H. Lieberman, and R. Newbery, " Fluorescence rejection in Raman spectroscopy by shifted-spectra, edge detection, and FFT filtering techniques.," Appl. Spectrosc. 49 (5), 9 (1995). 10.1366/0003702953964039
    • (1995) Appl. Spectrosc. , vol.49 , Issue.5 , pp. 9
    • Mosier-Boss, P.A.1    Lieberman, S.H.2    Newbery, R.3
  • 17
    • 0242498775 scopus 로고    scopus 로고
    • Automated method for subtraction of fluorescence from biological Raman spectra
    • 10.1366/000370203322554518
    • C. A. Lieber and A. Mahadevan-Jansen, " Automated method for subtraction of fluorescence from biological Raman spectra.," Appl. Spectrosc. 57 (11), 1363-1367 (2003). 10.1366/000370203322554518
    • (2003) Appl. Spectrosc. , vol.57 , Issue.11 , pp. 1363-1367
    • Lieber, C.A.1    Mahadevan-Jansen, A.2
  • 18
    • 0000651653 scopus 로고
    • Effective rejection of fluorescence interference in Raman spectroscopy using a shifted excitation difference technique
    • 10.1366/0003702924125122
    • A. P. Shreve, N. J. Cherepy, and R. A. Mathies, " Effective rejection of fluorescence interference in Raman spectroscopy using a shifted excitation difference technique.," Appl. Spectrosc. 46 (4), 5 (1992). 10.1366/0003702924125122
    • (1992) Appl. Spectrosc. , vol.46 , Issue.4 , pp. 5
    • Shreve, A.P.1    Cherepy, N.J.2    Mathies, R.A.3
  • 19
    • 0031073540 scopus 로고    scopus 로고
    • Near-infrared Raman spectrometer systems for human tissue studies
    • III, "," (),. 10.1366/0003702971940134
    • J. F. B. Brennan III, Y. Wang, R. R. Dasari, and M. S. Feld, " Near-infrared Raman spectrometer systems for human tissue studies.," Appl. Spectrosc. 51 (2), 201-208 (1997). 10.1366/0003702971940134
    • (1997) Appl. Spectrosc. , vol.51 , Issue.2 , pp. 201-208
    • Brennan, J.F.B.1    Wang, Y.2    Dasari, R.R.3    Feld, M.S.4
  • 20
  • 21
    • 0027228902 scopus 로고
    • Laser-induced changes in autofluorescence of in vivo skin
    • H. Zeng, C. MacAulay, B. Palcic, and D. I. McLean, " Laser-induced changes in autofluorescence of in vivo skin.," Proc. SPIE 1882, 278-290 (1993).
    • (1993) Proc. SPIE , vol.1882 , pp. 278-290
    • Zeng, H.1    MacAulay, C.2    Palcic, B.3    McLean, D.I.4
  • 22
    • 65449187548 scopus 로고    scopus 로고
    • A multimodal spectroscopy system for real-time disease diagnosis
    • 10.1063/1.3117832
    • O. cepanovic, Z. Volynskaya, C. R. Kong, L. Galindo, R. R. Dasari, and M. S. Feld, " A multimodal spectroscopy system for real-time disease diagnosis.," Rev. Sci. Instrum. 80 (4), 043103 (2009). 10.1063/1.3117832
    • (2009) Rev. Sci. Instrum. , vol.80 , Issue.4 , pp. 043103
    • Cepanovic, O.1    Volynskaya, Z.2    Kong, C.R.3    Galindo, L.4    Dasari, R.R.5    Feld, M.S.6
  • 23
    • 0031711549 scopus 로고    scopus 로고
    • Analysis of luminescent samples using subtracted shifted Raman spectroscopy
    • DOI 10.1039/a802802h
    • S. E. J. Bell, E. Bourguignon, and A. Dennis, " Analysis of luminescent samples using subtracted shifted Raman spectroscopy.," Analyst 123, 1729-1734 (1998). 10.1039/a802802h (Pubitemid 28408598)
    • (1998) Analyst , vol.123 , Issue.8 , pp. 1729-1734
    • Bell, S.E.J.1    Bourguignon, E.S.O.2    Dennis, A.3
  • 24
    • 0042553279 scopus 로고
    • Smoothing and differentiation of data by simplified least squares procedures
    • 10.1021/ac60214a047
    • A. Savitzky and M. J. E. Golay, " Smoothing and differentiation of data by simplified least squares procedures.," Anal. Chem. 36 (8), 1627-1639 (1964). 10.1021/ac60214a047
    • (1964) Anal. Chem. , vol.36 , Issue.8 , pp. 1627-1639
    • Savitzky, A.1    Golay, M.J.E.2
  • 25
  • 27
    • 0036649717 scopus 로고    scopus 로고
    • Automated fluorescence rejection using shifted excitation Raman difference spectroscopy
    • DOI 10.1366/000370202760171491
    • J. Zhao, M. M. Carrabba, and F. S. Allen, " Automated fluorescence rejection using shifted excitation Raman difference spectroscopy.," Appl. Spectrosc. 56 (7), 12 (2002). 10.1366/000370202760171491 (Pubitemid 34878789)
    • (2002) Applied Spectroscopy , vol.56 , Issue.7 , pp. 834-845
    • Zhao, J.1    Carrabba, M.M.2    Allen, F.S.3
  • 28
    • 34548185968 scopus 로고    scopus 로고
    • Shift-excitation Raman difference spectroscopy-difference deconvolution method for the luminescence background rejection from Raman spectra of solid samples
    • DOI 10.1366/000370207781540169
    • I. Osticioli, A. Zoppi, and E. M. Castellucci, " Shift-excitation Raman difference spectroscopy difference deconvolution method for the luminescence background rejection from Raman spectra of solid samples.," Appl. Spectrosc. 61 (8), 839-844 (2007). 10.1366/000370207781540169 (Pubitemid 47310430)
    • (2007) Applied Spectroscopy , vol.61 , Issue.8 , pp. 839-844
    • Osticioli, I.1    Zoppi, A.2    Castellucci, E.M.3
  • 29
    • 47849094124 scopus 로고    scopus 로고
    • Multi-excitation Raman spectroscopy technique for fluorescence rejection
    • 10.1364/OE.16.010975
    • S. T. McCain, R. M. Willet, and D. J. Brady, " Multi-excitation Raman spectroscopy technique for fluorescence rejection.," Opt. Expr. 16 (15), 10975-10991 (2008). 10.1364/OE.16.010975
    • (2008) Opt. Expr. , vol.16 , Issue.15 , pp. 10975-10991
    • McCain, S.T.1    Willet, R.M.2    Brady, D.J.3
  • 30
    • 67149108592 scopus 로고    scopus 로고
    • Method for automated background subtraction from Raman spectra containing known contaminants
    • 10.1039/b821856k
    • B. D. Beier and A. J. Berger, " Method for automated background subtraction from Raman spectra containing known contaminants.," Analyst 134, 1198-1202 (2009). 10.1039/b821856k
    • (2009) Analyst , vol.134 , pp. 1198-1202
    • Beier, B.D.1    Berger, A.J.2
  • 32
    • 0028309433 scopus 로고
    • Non-invasive blood glucose sensors based on near-infrared spectroscopy
    • 10.1111/j.1525-1594.1994.tb02230.x
    • H. M. Heise, R. Marbach, T. H. Koschinsky, and F. A. Gries, " Non-invasive blood glucose sensors based on near-infrared spectroscopy.," Artif. Organs 18 (6), 439-447 (1994). 10.1111/j.1525-1594.1994.tb02230.x
    • (1994) Artif. Organs , vol.18 , Issue.6 , pp. 439-447
    • Heise, H.M.1    Marbach, R.2    Koschinsky, T.H.3    Gries, F.A.4
  • 33
    • 0006247823 scopus 로고    scopus 로고
    • Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination
    • 10.1007/s002160050539
    • C. Fischbacher, K. U. Jagemann, K. Danzer, U. A. Mller, L. Papenkordt, and J. Schler, " Enhancing calibration models for non-invasive near-infrared spectroscopical blood glucose determination.," Fresenius J. Anal. Chem. 359 (1), 78-82 (1997). 10.1007/s002160050539
    • (1997) Fresenius J. Anal. Chem. , vol.359 , Issue.1 , pp. 78-82
    • Fischbacher, C.1    Jagemann, K.U.2    Danzer, K.3    Mller, U.A.4    Papenkordt, L.5    Schler, J.6
  • 34
    • 0000866310 scopus 로고
    • Criteria for the oral glucose tolerance test in pregnancy
    • J. B. O'Sullivan and C. M. Mahan, " Criteria for the oral glucose tolerance test in pregnancy.," Diabetes 13, 278-285 (1964).
    • (1964) Diabetes , vol.13 , pp. 278-285
    • O'Sullivan, J.B.1    Mahan, C.M.2
  • 35
    • 0028936805 scopus 로고
    • Obstetrics: Toward universal criteria for gestational diabetes: The 75-gram glucose tolerance test in pregnancy
    • 10.1016/0002-9378(95)90580-4
    • D. A. Sacks, J. S. Greenspoon, S. Abu-Fadil, H. M. Henry, G. Wolde-Tsadik, and J. F. F. Yao, " Obstetrics: toward universal criteria for gestational diabetes: the 75-gram glucose tolerance test in pregnancy.," Am. J. Obstet. Gynecol. 172 (2), 607-614 (1995). 10.1016/0002-9378(95)90580-4
    • (1995) Am. J. Obstet. Gynecol. , vol.172 , Issue.2 , pp. 607-614
    • Sacks, D.A.1    Greenspoon, J.S.2    Abu-Fadil, S.3    Henry, H.M.4    Wolde-Tsadik, G.5    Yao, J.F.F.6
  • 36
    • 0028204065 scopus 로고
    • Understanding oral glucose tolerance: Comparison of glucose or insulin measurements during the oral glucose tolerance test with specific measurements of insulin resistance and insulin secretion
    • 10.1111/j.1464-5491.1994.tb00273.x
    • D. I. Phillips, P. M. Clark, C. N. Hales, and C. Osmond, " Understanding oral glucose tolerance: comparison of glucose or insulin measurements during the oral glucose tolerance test with specific measurements of insulin resistance and insulin secretion.," Diabetic Med. 11 (3), 286-292 (1994). 10.1111/j.1464-5491.1994.tb00273.x
    • (1994) Diabetic Med. , vol.11 , Issue.3 , pp. 286-292
    • Phillips, D.I.1    Clark, P.M.2    Hales, C.N.3    Osmond, C.4
  • 37
    • 0033972911 scopus 로고    scopus 로고
    • Identification of dyes on ancient Chinese paper samples using the subtracted shifted raman spectroscopy method
    • DOI 10.1021/ac9909812
    • S. E. J. Bell, E. S. O. Bourguignon, A. C. Dennis, J. A. Fields, J. J. McGarvey, and K. R. Seddon, " Identification of dyes on ancient Chinese paper samples using the subtracted shifted Raman spectroscopy method.," Anal. Chem. 72 (1), 234-239 (2000). 10.1021/ac9909812 (Pubitemid 30027762)
    • (2000) Analytical Chemistry , vol.72 , Issue.1 , pp. 234-239
    • Bell, S.E.J.1    Bourguignon, E.S.O.2    Dennis, A.C.3    Fields, J.A.4    McGarvey, J.J.5    Seddon, K.R.6
  • 38
    • 0035326262 scopus 로고    scopus 로고
    • Quantitative Raman spectroscopy of highly fluorescent samples using pseudosecond derivatives and multivariate analysis
    • 10.1021/ac0010072
    • A. O'Grady, A. C. Dennis, D. Denvir, J. J. McGarvey, and S. E. Bell, " Quantitative Raman spectroscopy of highly fluorescent samples using pseudosecond derivatives and multivariate analysis.," Anal. Chem. 73 (9), 2058-2065 (2001). 10.1021/ac0010072
    • (2001) Anal. Chem. , vol.73 , Issue.9 , pp. 2058-2065
    • O'Grady, A.1    Dennis, A.C.2    Denvir, D.3    McGarvey, J.J.4    Bell, S.E.5
  • 40
    • 33748377085 scopus 로고    scopus 로고
    • The lag phase and G1 phase of a single yeast cell monitored by Raman microspectroscopy
    • 10.1002/jrs.1520
    • G. P. Singh, G. Volpe, C. M. Creely, H. Groetsch, I. M. Geli, and D. Petrov, " The lag phase and G1 phase of a single yeast cell monitored by Raman microspectroscopy.," J. Raman Spectrosc. 37, 858-864 (2006). 10.1002/jrs.1520
    • (2006) J. Raman Spectrosc. , vol.37 , pp. 858-864
    • Singh, G.P.1    Volpe, G.2    Creely, C.M.3    Groetsch, H.4    Geli, I.M.5    Petrov, D.6
  • 41
    • 3042551400 scopus 로고    scopus 로고
    • Multivariate calibration with least-squares support vector machines
    • DOI 10.1021/ac035522m
    • U. Thissen, B. Ustun, W. J. Melssen, and L. M. C. Buydens, " Multivariate calibration with least-squares support vector machines.," Anal. Chem. 76 (11), 3099-3105 (2004). 10.1021/ac035522m (Pubitemid 38715701)
    • (2004) Analytical Chemistry , vol.76 , Issue.11 , pp. 3099-3105
    • Thissen, U.1    Ustun, B.2    Melsseit, W.J.3    Buydens, L.M.C.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.