메뉴 건너뛰기




Volumn 72, Issue 3, 2014, Pages 880-892

Parameter estimation approach to banding artifact reduction in balanced steady-state free precession

Author keywords

banding artifacts; bSSFP; LORE; off resonance; parameter estimation

Indexed keywords

BIOMEDICAL SIGNAL PROCESSING; RESONANCE; SIGNAL TO NOISE RATIO;

EID: 85027937296     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24986     Document Type: Article
Times cited : (32)

References (26)
  • 2
    • 0023872880 scopus 로고
    • An analysis of fast imaging sequences with steady-state transverse magnetization refocusing
    • Zur Y, Stokar S, Bendel P,. An analysis of fast imaging sequences with steady-state transverse magnetization refocusing. Magn Reson Med 1988; 6: 175-193.
    • (1988) Magn Reson Med , vol.6 , pp. 175-193
    • Zur, Y.1    Stokar, S.2    Bendel, P.3
  • 3
    • 84863753720 scopus 로고    scopus 로고
    • Simple cross-solution for banding artifact removal in bSSFP imaging
    • Stockholm, Sweden
    • Xiang QS, Hoff MN,. Simple cross-solution for banding artifact removal in bSSFP imaging. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 74.
    • (2010) Proceedings of the 18th Annual Meeting of ISMRM , pp. 74
    • Xiang, Q.S.1    Hoff, M.N.2
  • 6
    • 0037370514 scopus 로고    scopus 로고
    • Rapid combined T 1 and T 2 mapping using gradient recalled acquisition in the steady state
    • Deoni SC, Rutt BK, Peters TM,. Rapid combined T 1 and T 2 mapping using gradient recalled acquisition in the steady state. Magn Reson Med 2003; 49: 515-526.
    • (2003) Magn Reson Med , vol.49 , pp. 515-526
    • Deoni, S.C.1    Rutt, B.K.2    Peters, T.M.3
  • 8
    • 68049142599 scopus 로고    scopus 로고
    • Transverse relaxation time (T 2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging
    • Deoni SC,. Transverse relaxation time (T 2) mapping in the brain with off-resonance correction using phase-cycled steady-state free precession imaging. J Magn Reson Imaging 2009; 30: 411-417.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 411-417
    • Deoni, S.C.1
  • 10
    • 0035095928 scopus 로고    scopus 로고
    • T1 quantification with inversion recovery TrueFISP
    • Scheffler K, Hennig J,. T1 quantification with inversion recovery TrueFISP. Magn Reson Med 2001; 45: 720-723.
    • (2001) Magn Reson Med , vol.45 , pp. 720-723
    • Scheffler, K.1    Hennig, J.2
  • 13
    • 0000629553 scopus 로고
    • Phase and intensity anomalies in Fourier transform NMR
    • Freeman R, Hill HDW,. Phase and intensity anomalies in Fourier transform NMR. J Magn Reson 1971; 4: 366-383.
    • (1971) J Magn Reson , vol.4 , pp. 366-383
    • Freeman, R.1    Hill, H.D.W.2
  • 14
    • 67649342778 scopus 로고    scopus 로고
    • Analytical characterization of RF phase-cycled balanced steady-state free precession
    • Lauzon ML, Frayne R,. Analytical characterization of RF phase-cycled balanced steady-state free precession. Concepts Magn Reson 2009; 34A: 133-143.
    • (2009) Concepts Magn Reson , vol.34 A , pp. 133-143
    • Lauzon, M.L.1    Frayne, R.2
  • 19
    • 0036668838 scopus 로고    scopus 로고
    • Understanding phase maps in MRI: A new cutline phase unwrapping method
    • Chavez S, Xiang QS, An L,. Understanding phase maps in MRI: a new cutline phase unwrapping method. IEEE Trans Med Imaging 2002; 21: 966-977.
    • (2002) IEEE Trans Med Imaging , vol.21 , pp. 966-977
    • Chavez, S.1    Xiang, Q.S.2    An, L.3
  • 22
    • 85091617290 scopus 로고    scopus 로고
    • Ultra-high resolution 0.4 mm isotropic structural imaging of the human hippocampus in vivo utilizing phase-cycled bSSFP at 7.0 t
    • San Diego, California, USA
    • Zeineh M, Parekh M, Su J, Rutt B,. Ultra-high resolution 0.4 mm isotropic structural imaging of the human hippocampus in vivo utilizing phase-cycled bSSFP at 7.0 t. In Proceedings of the American Society for Neuroradiology 51st Annual Meeting, San Diego, California, USA, 2013. p. 31.
    • (2013) Proceedings of the American Society for Neuroradiology 51st Annual Meeting , pp. 31
    • Zeineh, M.1    Parekh, M.2    Su, J.3    Rutt, B.4
  • 25
    • 61449085673 scopus 로고    scopus 로고
    • Iterative off-resonance and signal decay estimation and correction for multi-echo MRI
    • Knopp T, Eggers H, Dahnke H, Prestin J, Senegas J,. Iterative off-resonance and signal decay estimation and correction for multi-echo MRI. IEEE Trans Med Imaging 2009; 28: 394-404.
    • (2009) IEEE Trans Med Imaging , vol.28 , pp. 394-404
    • Knopp, T.1    Eggers, H.2    Dahnke, H.3    Prestin, J.4    Senegas, J.5
  • 26
    • 51449112832 scopus 로고    scopus 로고
    • Quantitative magnetization transfer imaging using balanced SSFP
    • Gloor M, Scheffler K, Bieri O,. Quantitative magnetization transfer imaging using balanced SSFP. Magn Reson Med 2008; 60: 691-700.
    • (2008) Magn Reson Med , vol.60 , pp. 691-700
    • Gloor, M.1    Scheffler, K.2    Bieri, O.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.