메뉴 건너뛰기




Volumn 238, Issue , 2017, Pages 1181-1189

Calibration update strategies for an array of potentiometric chemical sensors

Author keywords

Calibration update; Electronic tongue; Joint Y partial least square regression; Multivariate calibration standardization; Tikhonov regularization; Weighting

Indexed keywords

INFRARED DEVICES; MULTIVARIANT ANALYSIS; POTENTIOMETERS (ELECTRIC MEASURING INSTRUMENTS); POTENTIOMETRIC SENSORS; REGRESSION ANALYSIS; STANDARDIZATION; STATISTICAL METHODS; TRANSITION METALS;

EID: 85027927221     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2016.06.075     Document Type: Article
Times cited : (24)

References (29)
  • 2
    • 33847803289 scopus 로고
    • Theoretical treatment of the selectivity and detection limit of silver compound membrane electrodes
    • [2] Morf, W.E., Kahr, G., Simon, W., Theoretical treatment of the selectivity and detection limit of silver compound membrane electrodes. Anal. Chem. 46 (1974), 1538-1543.
    • (1974) Anal. Chem. , vol.46 , pp. 1538-1543
    • Morf, W.E.1    Kahr, G.2    Simon, W.3
  • 3
    • 0037783793 scopus 로고    scopus 로고
    • A multi-technique surface study of the mercury(II) chalcogenide ion-selective electrode in saline media
    • [3] De Marco, R., Pejcic, B., Prince, K., van Riessen, A., A multi-technique surface study of the mercury(II) chalcogenide ion-selective electrode in saline media. Analyst 128 (2003), 742-749.
    • (2003) Analyst , vol.128 , pp. 742-749
    • De Marco, R.1    Pejcic, B.2    Prince, K.3    van Riessen, A.4
  • 4
    • 0002232006 scopus 로고    scopus 로고
    • Selectivity of liquid membrane ion-selective electrodes
    • [4] Bakker, E., Selectivity of liquid membrane ion-selective electrodes. Electroanalysis 9 (1997), 7-12.
    • (1997) Electroanalysis , vol.9 , pp. 7-12
    • Bakker, E.1
  • 5
    • 0000920105 scopus 로고
    • Multivariate instrument standardization
    • [5] Wang, Y., Veltkamp, D.J., Kowalski, B.R., Multivariate instrument standardization. Anal. Chem. 63 (1991), 2750-2756.
    • (1991) Anal. Chem. , vol.63 , pp. 2750-2756
    • Wang, Y.1    Veltkamp, D.J.2    Kowalski, B.R.3
  • 8
    • 39549114809 scopus 로고    scopus 로고
    • A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers
    • [8] Pereira, C.F., Pimentel, M.F., Galvão, R.K.H., Honorato, F.A., Stragevitch, L., Martins, M.N., A comparative study of calibration transfer methods for determination of gasoline quality parameters in three different near infrared spectrometers. Anal. Chim. Acta 611 (2008), 41-47.
    • (2008) Anal. Chim. Acta , vol.611 , pp. 41-47
    • Pereira, C.F.1    Pimentel, M.F.2    Galvão, R.K.H.3    Honorato, F.A.4    Stragevitch, L.5    Martins, M.N.6
  • 9
    • 0033517145 scopus 로고    scopus 로고
    • Weighting schemes for updating regression models - a theoretical approach
    • [9] Stork, C.L., Kowalski, B.R., Weighting schemes for updating regression models - a theoretical approach. Chemom. Intell. Lab. Syst. 48 (1999), 151-166.
    • (1999) Chemom. Intell. Lab. Syst. , vol.48 , pp. 151-166
    • Stork, C.L.1    Kowalski, B.R.2
  • 10
    • 15744366659 scopus 로고    scopus 로고
    • Selection and weighting of samples in multivariate, regression model updating
    • [10] Capron, X., Walczak, B., de Noord, O.E., Massart, D.L., Selection and weighting of samples in multivariate, regression model updating. Chemom. Intell. Lab. Syst. 76 (2005), 205-214.
    • (2005) Chemom. Intell. Lab. Syst. , vol.76 , pp. 205-214
    • Capron, X.1    Walczak, B.2    de Noord, O.E.3    Massart, D.L.4
  • 11
    • 68349114771 scopus 로고    scopus 로고
    • Calibration maintenance and transfer using Tikhonov regularization approaches
    • [11] Kalivas, J.H., Siano, G.G., Andries, E., Goicoechea, H.C., Calibration maintenance and transfer using Tikhonov regularization approaches. Appl. Spectrosc. 63 (2009), 800-809.
    • (2009) Appl. Spectrosc. , vol.63 , pp. 800-809
    • Kalivas, J.H.1    Siano, G.G.2    Andries, E.3    Goicoechea, H.C.4
  • 12
    • 77951083710 scopus 로고    scopus 로고
    • Impact of standardization sample design on Tikhonov regularization variants for spectroscopic calibration maintenance and transfer
    • [12] Kunz, M.R., Ottaway, J., Kalivas, J.H., Andries, E., Impact of standardization sample design on Tikhonov regularization variants for spectroscopic calibration maintenance and transfer. J. Chemom. 24 (2010), 218-229.
    • (2010) J. Chemom. , vol.24 , pp. 218-229
    • Kunz, M.R.1    Ottaway, J.2    Kalivas, J.H.3    Andries, E.4
  • 13
    • 77951854153 scopus 로고    scopus 로고
    • Model updating for spectral calibration maintenance and transfer using 1-norm variants of Tikhonov regularization
    • [13] Kunz, M.R., Kalivas, J.H., Andries, E., Model updating for spectral calibration maintenance and transfer using 1-norm variants of Tikhonov regularization. Anal. Chem. 82 (2010), 3642-3649.
    • (2010) Anal. Chem. , vol.82 , pp. 3642-3649
    • Kunz, M.R.1    Kalivas, J.H.2    Andries, E.3
  • 14
    • 0032809579 scopus 로고    scopus 로고
    • Multivariate standardization techniques on ion-selective sensor arrays
    • [14] Sales, F., Callao, M.P., Rius, F.X., Multivariate standardization techniques on ion-selective sensor arrays. Analyst 124 (1999), 1045-1051.
    • (1999) Analyst , vol.124 , pp. 1045-1051
    • Sales, F.1    Callao, M.P.2    Rius, F.X.3
  • 15
    • 0034072607 scopus 로고    scopus 로고
    • Multivariate standardization for correcting the ionic strength variation on potentiometric sensor arrays
    • [15] Sales, F., Callao, M.P., Rius, F.X., Multivariate standardization for correcting the ionic strength variation on potentiometric sensor arrays. Analyst 125 (2000), 883-888.
    • (2000) Analyst , vol.125 , pp. 883-888
    • Sales, F.1    Callao, M.P.2    Rius, F.X.3
  • 16
    • 84961231162 scopus 로고    scopus 로고
    • Calibration transfer in temperature modulated gas sensor arrays
    • [16] Fernandez, L., Guney, S., Gutierrez-Galvez, A., Marco, S., Calibration transfer in temperature modulated gas sensor arrays. Sens. Actuators B 231 (2016), 276-284.
    • (2016) Sens. Actuators B , vol.231 , pp. 276-284
    • Fernandez, L.1    Guney, S.2    Gutierrez-Galvez, A.3    Marco, S.4
  • 17
    • 0030583843 scopus 로고    scopus 로고
    • Correction of mass spectral drift using artificial neural networks
    • [17] Goodacre, R., Kell, D.B., Correction of mass spectral drift using artificial neural networks. Anal. Chem. 68 (1996), 271-280.
    • (1996) Anal. Chem. , vol.68 , pp. 271-280
    • Goodacre, R.1    Kell, D.B.2
  • 18
    • 0032069959 scopus 로고    scopus 로고
    • Product design through multivariate statistical analysis of process data
    • [18] Jaeckle, C.M., MacGregor, J.F., Product design through multivariate statistical analysis of process data. AIChE J. 44 (1998), 1105-1118.
    • (1998) AIChE J. , vol.44 , pp. 1105-1118
    • Jaeckle, C.M.1    MacGregor, J.F.2
  • 19
    • 0034306754 scopus 로고    scopus 로고
    • Product transfer between plants using historical process data
    • [19] Jaeckle, C.M., MacGregor, J.F., Product transfer between plants using historical process data. AIChE J. 46 (2000), 1989-1997.
    • (2000) AIChE J. , vol.46 , pp. 1989-1997
    • Jaeckle, C.M.1    MacGregor, J.F.2
  • 21
    • 84861925118 scopus 로고    scopus 로고
    • Transfer of process monitoring models between different plants using latent variable techniques
    • [21] Facco, P., Tomba, E., Bezzo, F., Garcia-Munoz, S., Barolo, M., Transfer of process monitoring models between different plants using latent variable techniques. Ind. Eng. Chem. Res. 51 (2012), 7327-7339.
    • (2012) Ind. Eng. Chem. Res. , vol.51 , pp. 7327-7339
    • Facco, P.1    Tomba, E.2    Bezzo, F.3    Garcia-Munoz, S.4    Barolo, M.5
  • 22
    • 84902126858 scopus 로고    scopus 로고
    • Detection of copper lead, cadmium and iron in wine using electronic tongue sensor system
    • [22] Simões Costa, A.M., Delgadillo, I., Rudnitskaya, A., Detection of copper lead, cadmium and iron in wine using electronic tongue sensor system. Talanta 129 (2014), 63-71.
    • (2014) Talanta , vol.129 , pp. 63-71
    • Simões Costa, A.M.1    Delgadillo, I.2    Rudnitskaya, A.3
  • 24
    • 0042878854 scopus 로고    scopus 로고
    • Cross-sensitivity of chalcogenide glass sensors in solutions of heavy metal ions
    • [24] Legin, A.V., Vlasov, Yu.G., Rudnitskaya, A.M., Bychkov, E.A., Cross-sensitivity of chalcogenide glass sensors in solutions of heavy metal ions. Sens. Actuators B 34 (1996), 456-461.
    • (1996) Sens. Actuators B , vol.34 , pp. 456-461
    • Legin, A.V.1    Vlasov, Y.G.2    Rudnitskaya, A.M.3    Bychkov, E.A.4
  • 27
    • 84894887900 scopus 로고
    • Computer aided design of experiments
    • [27] Kennard, W., Stone, L.A., Computer aided design of experiments. Technometrics 11 (1969), 137-148.
    • (1969) Technometrics , vol.11 , pp. 137-148
    • Kennard, W.1    Stone, L.A.2
  • 28
    • 0037185468 scopus 로고    scopus 로고
    • Graphical diagnostics for regression model determinations with consideration of the bias/variance trade-off
    • [28] Green, R.L., Kalivas, J.H., Graphical diagnostics for regression model determinations with consideration of the bias/variance trade-off. Chemom. Intell. Lab. Syst. 60 (2002), 173-188.
    • (2002) Chemom. Intell. Lab. Syst. , vol.60 , pp. 173-188
    • Green, R.L.1    Kalivas, J.H.2
  • 29
    • 0000079353 scopus 로고    scopus 로고
    • Propagation of measurement errors for the validation of predictions obtained by principal component regression and partial least squares
    • [29] Faber, K., Kowalski, B.R., Propagation of measurement errors for the validation of predictions obtained by principal component regression and partial least squares. J. Chemom. 11 (1997), 181-238.
    • (1997) J. Chemom. , vol.11 , pp. 181-238
    • Faber, K.1    Kowalski, B.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.