Volumn 23, Issue 5, 2017, Pages e469-e470

The coagulation laboratory monitoring of Afstyla single-chain FVIII concentrate

Author keywords

[No Author keywords available]

Indexed keywords

BLOOD CLOTTING FACTOR 8; RECOMBINANT BLOOD CLOTTING FACTOR 8; VON WILLEBRAND FACTOR;

EID: 85021441807     PISSN: 13518216     EISSN: 13652516     Source Type: Journal    
DOI: 10.1111/hae.13290     Document Type: Letter
Times cited : (21)

References (9)
  • 1
    • 84894260830 scopus 로고    scopus 로고
    • Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories
    • Sommer JM, Moore N, Mcguffie-Valentine B, et al. Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories. Haemophilia. 2014;20:294–300.
    • (2014) Haemophilia , vol.20 , pp. 294-300
    • Sommer, J.M.1    Moore, N.2    Mcguffie-Valentine, B.3
  • 2
    • 84994275833 scopus 로고    scopus 로고
    • A world-wide survey and field study in clinical haemostasis laboratories to evaluate FVIII: C activity assay variability of ADYNOVATE and OBIZUR in comparison with ADVATE
    • Turecek PL, Romeda-Finger S, Apostol C. A world-wide survey and field study in clinical haemostasis laboratories to evaluate FVIII: C activity assay variability of ADYNOVATE and OBIZUR in comparison with ADVATE. Haemophilia. 2016;22:957–965.
    • (2016) Haemophilia , vol.22 , pp. 957-965
    • Turecek, P.L.1    Romeda-Finger, S.2    Apostol, C.3
  • 3
    • 84904723193 scopus 로고    scopus 로고
    • Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94-9027) for haemophilia A
    • Gu J, Ramsey P, Evans V, et al. Evaluation of the activated partial thromboplastin time assay for clinical monitoring of PEGylated recombinant factor VIII (BAY 94-9027) for haemophilia A. Haemophilia. 2014;20:593–600.
    • (2014) Haemophilia , vol.20 , pp. 593-600
    • Gu, J.1    Ramsey, P.2    Evans, V.3
  • 4
    • 84990198558 scopus 로고    scopus 로고
    • Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two centre study
    • Bowyer AE, Hillarp A, Ezban M, Persson P, Kitchen S. Measuring factor IX activity of nonacog beta pegol with commercially available one-stage clotting and chromogenic assay kits: a two centre study. J Thromb Haemost. 2016;14:1428–1435.
    • (2016) J Thromb Haemost , vol.14 , pp. 1428-1435
    • Bowyer, A.E.1    Hillarp, A.2    Ezban, M.3    Persson, P.4    Kitchen, S.5
  • 5
    • 84923326141 scopus 로고    scopus 로고
    • Recombinant factor IX: discrepancies between one-stage clotting and chromogenic assays
    • Wilmot HV, Hogwood, J. Gray, E. Recombinant factor IX: discrepancies between one-stage clotting and chromogenic assays. Haemophilia. 2014;20:981–987.
    • (2014) Haemophilia , vol.20 , pp. 981-987
    • Wilmot, H.V.1    Hogwood, J.2    Gray, E.3
  • 6
    • 84938556132 scopus 로고    scopus 로고
    • Physicochemical characterisation of rVIII-SingleChain, a novel recombinant single-chain factor VIII
    • Schmidbauer S, Witzel R, Robbel L, Sebastian P, Grammel N, Metzner HJ, Schulte S, et al. Physicochemical characterisation of rVIII-SingleChain, a novel recombinant single-chain factor VIII. Thromb Res. 2015;136:388–395.
    • (2015) Thromb Res , vol.136 , pp. 388-395
    • Schmidbauer, S.1    Witzel, R.2    Robbel, L.3    Sebastian, P.4    Grammel, N.5    Metzner, H.J.6    Schulte, S.7
  • 8
    • 85016327498 scopus 로고    scopus 로고
    • Characteristics of rVIII-SingleChain in the one-stage and the chromogenic substrate assay: results of an international field study
    • St Ledger K, Fuessner A, Kalina U, et al. Characteristics of rVIII-SingleChain in the one-stage and the chromogenic substrate assay: results of an international field study. Haemophilia. 2016;22(Suppl. 4):59.
    • (2016) Haemophilia , vol.22 , pp. 59
    • St Ledger, K.1    Fuessner, A.2    Kalina, U.3
  • 9
    • 84979083925 scopus 로고    scopus 로고
    • The use of enhanced half-life coagulation factor concentrates in routine clinical practice: guidance from UKHCDO
    • Collins PW, Chalmers E, Chowdary P, et al. The use of enhanced half-life coagulation factor concentrates in routine clinical practice: guidance from UKHCDO. Haemophilia. 2016;22:487–498.
    • (2016) Haemophilia , vol.22 , pp. 487-498
    • Collins, P.W.1    Chalmers, E.2    Chowdary, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.