메뉴 건너뛰기




Volumn 1607, Issue , 2017, Pages 165-184

Collection of X-ray diffraction data from macromolecular crystals

Author keywords

Data collection strategy; Diffraction data collection; Diffraction data quality

Indexed keywords

CRYSTAL STRUCTURE; INFORMATION PROCESSING; MACROMOLECULE; RADIATION EXPOSURE; RADIATION INJURY; ROTATION; SIGNAL NOISE RATIO; STRUCTURAL MODEL; STRUCTURE ANALYSIS; SYNCHROTRON RADIATION; UNCERTAINTY; X RAY BEAM LIMITING DEVICE; X RAY DIFFRACTION; CHEMISTRY; CRYSTALLIZATION; IMAGE PROCESSING; PROCEDURES; PROTEIN CONFORMATION; STATISTICAL ANALYSIS; STATISTICS AND NUMERICAL DATA; SYNCHROTRON; ULTRASTRUCTURE; X RAY CRYSTALLOGRAPHY;

EID: 85020161164     PISSN: 10643745     EISSN: None     Source Type: Book Series    
DOI: 10.1007/978-1-4939-7000-1_7     Document Type: Chapter
Times cited : (24)

References (20)
  • 3
    • 0012719697 scopus 로고    scopus 로고
    • Principles of monochromatic data collection
    • Rossmann MG, Arnold E (eds), Kluwer Academic, Dordrecht
    • Dauter Z, Wilson KS (2001) Principles of monochromatic data collection. In: Rossmann MG, Arnold E (eds) International tables for crystallography, vol. F. Kluwer Academic, Dordrecht, pp 177–195
    • (2001) International Tables for Crystallography, Vol. F , pp. 177-195
    • Dauter, Z.1    Wilson, K.S.2
  • 4
    • 0038116629 scopus 로고    scopus 로고
    • Choice of data-collection parameters based on statistic modelling
    • Popov AN, Bourenkov GP (2003) Choice of data-collection parameters based on statistic modelling. Acta Crystallogr D Biol Crystallogr 59:1145–1153
    • (2003) Acta Crystallogr D Biol Crystallogr , vol.59 , pp. 1145-1153
    • Popov, A.N.1    Bourenkov, G.P.2
  • 6
    • 84944818485 scopus 로고
    • Multiplicity distribution of reflections in Laue diffraction
    • Cruickshank DWJ, Helliwell JR, Moffat K (1987) Multiplicity distribution of reflections in Laue diffraction. Acta Crystallogr A 43:656–674
    • (1987) Acta Crystallogr A , vol.43 , pp. 656-674
    • Cruickshank, D.1    Helliwell, J.R.2    Moffat, K.3
  • 7
    • 77950813607 scopus 로고    scopus 로고
    • Radiation damage in macromolecular crystallography: What is it and why should we care?
    • Garman EF (2010) Radiation damage in macromolecular crystallography: what is it and why should we care? Acta Crystallogr D Biol Crystallogr 66:339–351
    • (2010) Acta Crystallogr D Biol Crystallogr , vol.66 , pp. 339-351
    • Garman, E.F.1
  • 8
    • 33645498518 scopus 로고    scopus 로고
    • Experimental determination of the radiation dose limit for cryocooled protein crystals
    • Owen RL, Rudiño-Pinera R, Garman EF (2006) Experimental determination of the radiation dose limit for cryocooled protein crystals. Proc Natl Acad Sci U S A 103: 4912–4917
    • (2006) Proc Natl Acad Sci U S A , vol.103 , pp. 4912-4917
    • Owen, R.L.1    Rudiño-Pinera, R.2    Garman, E.F.3
  • 9
    • 0031059039 scopus 로고    scopus 로고
    • Detecting and overcoming crystal twinning
    • Yeates TO (1997) Detecting and overcoming crystal twinning. Methods Enzymol 276: 344–358
    • (1997) Methods Enzymol , vol.276 , pp. 344-358
    • Yeates, T.O.1
  • 10
    • 77951938696 scopus 로고    scopus 로고
    • Xtriage and Fest: Automatic assessment of data quality and substructure structure factor estimation
    • Zwart PH, Grosse-Kunstleve RW, Adams PD (2005) Xtriage and Fest: automatic assessment of data quality and substructure structure factor estimation. CCP4 Newsletter 43
    • (2005) CCP4 Newsletter , vol.43
    • Zwart, P.H.1    Grosse-Kunstleve, R.W.2    Adams, P.D.3
  • 12
    • 0035121475 scopus 로고    scopus 로고
    • CHOOCH: A program for deriving anomalous-scattering factors from X-ray fluorescence spectra
    • Evans G, Pettifer R (2001) CHOOCH: a program for deriving anomalous-scattering factors from X-ray fluorescence spectra. J Appl Crystallogr 34:82–86
    • (2001) J Appl Crystallogr , vol.34 , pp. 82-86
    • Evans, G.1    Pettifer, R.2
  • 13
    • 32944456529 scopus 로고    scopus 로고
    • On the routine use of soft X-rays in macromolecular crystallography. Part III. The optimal data collection wavelength
    • Mueller-Dieckmann C, Panjikar S, Tucker PA, Weiss MS (2005) On the routine use of soft X-rays in macromolecular crystallography. Part III. The optimal data collection wavelength. Acta Crystallogr D Biol Crystallogr 61:1263–1272
    • (2005) Acta Crystallogr D Biol Crystallogr , vol.61 , pp. 1263-1272
    • Mueller-Dieckmann, C.1    Panjikar, S.2    Tucker, P.A.3    Weiss, M.S.4
  • 14
    • 0030915704 scopus 로고    scopus 로고
    • Improved R-factor for diffraction data analysis in macromolecular crystallography
    • Diederichs K, Karplus PA (1997) Improved R-factor for diffraction data analysis in macromolecular crystallography. Nat Struct Biol 4:269–275
    • (1997) Nat Struct Biol , vol.4 , pp. 269-275
    • Diederichs, K.1    Karplus, P.A.2
  • 15
    • 0000330205 scopus 로고    scopus 로고
    • On the use of merging R factor as a quality indicator for X-ray data
    • Weiss MS, Hilgenfeld R (1997) On the use of merging R factor as a quality indicator for X-ray data. J Appl Crystallogr 30:203–205
    • (1997) J Appl Crystallogr , vol.30 , pp. 203-205
    • Weiss, M.S.1    Hilgenfeld, R.2
  • 16
    • 84861425552 scopus 로고    scopus 로고
    • Linking crystallographic model and data quality
    • Karplus PA, Diederichs K (2012) Linking crystallographic model and data quality. Science 336:1030–1033
    • (2012) Science , vol.336 , pp. 1030-1033
    • Karplus, P.A.1    Diederichs, K.2
  • 17
    • 84939428576 scopus 로고    scopus 로고
    • Estimation of the quality of refined protein crystal structures
    • Wang J (2015) Estimation of the quality of refined protein crystal structures. Protein Sci 24:661–669
    • (2015) Protein Sci , vol.24 , pp. 661-669
    • Wang, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.