Volumn 21, Issue , 2017, Pages 33-49

Comprehensive investigation of transport refrigeration life cycle climate performance

Author keywords

Alternative technologies; Food product refrigerating temperature; Food transport refrigeration; Global warming; Life cycle climate performance; R452A

Indexed keywords

CARBON DIOXIDE; CHEMICAL CONTAMINATION; EMISSION CONTROL; ENVIRONMENTAL IMPACT; ENVIRONMENTAL MANAGEMENT; ENVIRONMENTAL TECHNOLOGY; GLOBAL WARMING; REFRIGERATION;

EID: 85018621025     PISSN: 22131388     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.seta.2017.04.002     Document Type: Article
Times cited : (65)

References (26)
  • 1
    • 0003459107 scopus 로고    scopus 로고
    • IPCC Fourth Assessment Report, the Physical Science Basis. (accessed May 2013.).
    • [1] Intergovernmental Panel on Climate Change (IPCC), 2007. IPCC Fourth Assessment Report, the Physical Science Basis. http://www.ipcc.ch/ipccreports/ar4-wg1.htm (accessed May 2013.).
    • (2007) Intergovernmental Panel on Climate Change (IPCC)
  • 4
    • 85018532965 scopus 로고    scopus 로고
    • [4] Estrada-Flores S. Chain of thought [Vol. 1, No. 2, April 2008]. http://www.food-chain.com.au/FCI_enews2.pdf; 2008.
    • (2008) Chain of thought , vol.1 , Issue.2
    • Estrada-Flores, S.1
  • 5
    • 84906291591 scopus 로고    scopus 로고
    • The validity of food miles as an indicator of sustainable development – Final report for DEFRA. Didcot: AEA Technology, UK
    • [5] AEA Technology. The validity of food miles as an indicator of sustainable development – Final report for DEFRA. Didcot: AEA Technology, UK; 2005.
    • (2005) AEA Technology
  • 6
    • 84879230206 scopus 로고    scopus 로고
    • The validity of food miles as an indicator of sustainable development. London: Defra, UK
    • [6] Department for Environment, Food and Rural Affairs (defra). The validity of food miles as an indicator of sustainable development. London: Defra, UK; 2005.
    • (2005) Department for Environment, Food and Rural Affairs (defra)
  • 9
    • 85018600315 scopus 로고    scopus 로고
    • [9] IIR LCCP WP: http://www.iifiir.org/medias/medias.aspx?INSTANCE=EXPLOITATION&PORTAL_ID=portal_model_instance__WP_LCCP_Evaluation.xml.
    • IIR, L.W.1
  • 10
    • 84935862036 scopus 로고    scopus 로고
    • A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants
    • [10] Beshr, M., Aute, V., Sharma, V., Abdelaziz, O., Fricke, B., Radermacher, R., A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants. Int J Refrig 56 (2015), 154–164.
    • (2015) Int J Refrig , vol.56 , pp. 154-164
    • Beshr, M.1    Aute, V.2    Sharma, V.3    Abdelaziz, O.4    Fricke, B.5    Radermacher, R.6
  • 11
    • 84939173358 scopus 로고    scopus 로고
    • Investigations of life cycle climate performance and material life cycle assessment of packaged air conditioners for residential application
    • [11] Li, G., Investigations of life cycle climate performance and material life cycle assessment of packaged air conditioners for residential application. Sustainable Energy Technol Assess 11 (2015), 114–125.
    • (2015) Sustainable Energy Technol Assess , vol.11 , pp. 114-125
    • Li, G.1
  • 12
    • 84919398084 scopus 로고    scopus 로고
    • Comprehensive investigations of life cycle climate performance of packaged air source heat pumps for residential application
    • [12] Li, G., Comprehensive investigations of life cycle climate performance of packaged air source heat pumps for residential application. Renew Sustain Energy Rev 43 (2015), 702–710.
    • (2015) Renew Sustain Energy Rev , vol.43 , pp. 702-710
    • Li, G.1
  • 14
    • 77957348897 scopus 로고    scopus 로고
    • GREEN-MAC-LCCP: A Tool for Assessing the Life Cycle Climate Performance of MAC Systems
    • [14] Papasavva, S., Hill, W., Andersen, S., GREEN-MAC-LCCP: A Tool for Assessing the Life Cycle Climate Performance of MAC Systems. J Environ Sci Technol 44 (2010), 7666–7672.
    • (2010) J Environ Sci Technol , vol.44 , pp. 7666-7672
    • Papasavva, S.1    Hill, W.2    Andersen, S.3
  • 16
    • 84894000904 scopus 로고    scopus 로고
    • Scientific assessment of stratospheric ozone. Report no 44. In: Presented at the WMO Global Ozone Research and Monitoring Project
    • [16] World Meteorological Organization (WMO). Scientific assessment of stratospheric ozone. Report no 44. In: Presented at the WMO Global Ozone Research and Monitoring Project; 1999.
    • (1999) World Meteorological Organization (WMO)
  • 17
    • 85018573080 scopus 로고    scopus 로고
    • Kyoto protocol to the United Nations framework convention on climate change. (accessed June 2012.).
    • [17] United Nations Framework Convention on Climate Change (UNFCCC), 1998. Kyoto protocol to the United Nations framework convention on climate change. http://unfccc.int/essential_background/kyoto_protocol/items/1678.php (accessed June 2012.).
    • (1998) United Nations Framework Convention on Climate Change (UNFCCC)
  • 18
    • 85018585285 scopus 로고    scopus 로고
    • In: Presented at the Proceedings of International Conference on Ozone Protection Technologies, Washington DC, USA
    • [18] Orfeo S.R. A history of the TEWI process. In: Presented at the Proceedings of International Conference on Ozone Protection Technologies, Washington DC, USA; 1996.
    • (1996) Orfeo S.R. A history of the TEWI process
  • 19
  • 20
    • 1842479938 scopus 로고    scopus 로고
    • Life cycle assessment: Part 1: Framework, goal and scope definition, inventory analysis, and applications
    • [20] Rebitzer, G., Ekvall, T., Frischknecht, R., Hunkeler, D., Norris, G., Rydberg, T., et al. Life cycle assessment: Part 1: Framework, goal and scope definition, inventory analysis, and applications. Environ Int 30:5 (2004), 701–720.
    • (2004) Environ Int , vol.30 , Issue.5 , pp. 701-720
    • Rebitzer, G.1    Ekvall, T.2    Frischknecht, R.3    Hunkeler, D.4    Norris, G.5    Rydberg, T.6
  • 21
    • 85018542971 scopus 로고    scopus 로고
    • Method of Testing and Rating Heat Transmission of Controlled Temperature Vehicle/Domestic Containers.
    • [21] TTMA RP 38-07, 2007, Method of Testing and Rating Heat Transmission of Controlled Temperature Vehicle/Domestic Containers.
    • (2007) TTMA RP 38-07
  • 22
    • 85018569021 scopus 로고    scopus 로고
    • Standard for Performance Rating of Mechanical Transport Refrigeration Units, Air-Conditioning, Heating, & Refrigeration Institute, Arlington VA, 22201
    • [22] ANSI/AHRI Standard 1110 2013 Standard for Performance Rating of Mechanical Transport Refrigeration Units, Air-Conditioning, Heating, & Refrigeration Institute, Arlington VA, 22201.
    • (2013) ANSI/AHRI Standard 1110
  • 25
    • 3042724670 scopus 로고    scopus 로고
    • Design, construction and testing of an aircycle refrigeration system for road transport
    • [25] Spence, S.W.T., Doran, W.J., Artt, D.W., Design, construction and testing of an aircycle refrigeration system for road transport. Int J Refrig 27 (2004), 503–510.
    • (2004) Int J Refrig , vol.27 , pp. 503-510
    • Spence, S.W.T.1    Doran, W.J.2    Artt, D.W.3
  • 26
    • 13844254100 scopus 로고    scopus 로고
    • Performance analysis of a feasible air-cycle refrigeration system for road transport
    • [26] Spence, S.W.T., Doran, W.J., Artt, D.W., McCullough, G., Performance analysis of a feasible air-cycle refrigeration system for road transport. Int J Refrig 27 (2005), 381–388.
    • (2005) Int J Refrig , vol.27 , pp. 381-388
    • Spence, S.W.T.1    Doran, W.J.2    Artt, D.W.3    McCullough, G.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.