메뉴 건너뛰기




Volumn 11, Issue , 2015, Pages 114-125

Investigations of life cycle climate performance and material life cycle assessment of packaged air conditioners for residential application

Author keywords

Air conditioner; Life cycle assessment; Life cycle climate performance; Material; Packaged; Seasonal energy efficiency ratio

Indexed keywords

AIR CONDITIONING; CARBON; CARBON DIOXIDE; DOMESTIC APPLIANCES; EMISSION CONTROL; ENERGY EFFICIENCY; ENERGY UTILIZATION; ENVIRONMENTAL MANAGEMENT; MATERIALS; REFRIGERANTS;

EID: 84939173358     PISSN: 22131388     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.seta.2015.07.002     Document Type: Article
Times cited : (41)

References (19)
  • 2
    • 0034468895 scopus 로고    scopus 로고
    • Life cycle energy, costs and strategies for improving a single family house
    • Keolian G., Blanchard S., Reppe P. Life cycle energy, costs and strategies for improving a single family house. J Ind Ecol 2000, 4(2):135-157.
    • (2000) J Ind Ecol , vol.4 , Issue.2 , pp. 135-157
    • Keolian, G.1    Blanchard, S.2    Reppe, P.3
  • 3
    • 2642547994 scopus 로고    scopus 로고
    • Environmental impact assessment using a weighting method for alternative air-conditioning systems
    • Heikkilä K. Environmental impact assessment using a weighting method for alternative air-conditioning systems. Build Environ 2004, 39(10):1133-1140.
    • (2004) Build Environ , vol.39 , Issue.10 , pp. 1133-1140
    • Heikkilä, K.1
  • 5
    • 84939160696 scopus 로고    scopus 로고
    • V1.0
    • Life Cycle Climate Performance, V1.0, 2014. Available at: . http://lccp.%20umd.edu/ornllccp/.
    • (2014)
  • 6
    • 84939135893 scopus 로고    scopus 로고
    • ANSI/AHRI Standard 210/240. Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment. Arlington, Virginia
    • ANSI/AHRI Standard 210/240. Performance Rating of Unitary Air-Conditioning & Air-Source Heat Pump Equipment. Arlington, Virginia; 2008.
    • (2008)
  • 12
    • 37249058140 scopus 로고    scopus 로고
    • Source energy and emission factors for energy use in buildings.
    • NREL Technical Report NREL/TP-550-38617. National Renewable Energy Laboratory: Golden, CO
    • Deru M, Torcellini P. Source energy and emission factors for energy use in buildings. NREL Technical Report NREL/TP-550-38617. National Renewable Energy Laboratory: Golden, CO; 2007.
    • (2007)
    • Deru, M.1    Torcellini, P.2
  • 14
    • 84939189489 scopus 로고    scopus 로고
    • 1991-2005 Update: Typical Meteorological Year 3. Renewable Resource Data Center, National Renewable Energy Laboratory: Golden, CO
    • NREL, National Solar Radiation Data Base. 1991-2005 Update: Typical Meteorological Year 3. Renewable Resource Data Center, National Renewable Energy Laboratory: Golden, CO; 2012. Available at: . http://rredc.nrel.gov/solar/old_data/nsrdb/19912005/tmy3/by_state_and_city.html.
    • (2012)
  • 15
    • 84939149550 scopus 로고    scopus 로고
    • Fourth assessment report: climate change. Geneva, Switzerland
    • IPCC. Fourth assessment report: climate change. Geneva, Switzerland, 2007.
    • (2007)
  • 16
    • 84939212703 scopus 로고
    • (DOE2 90) LBL-19735, Rev. 1 Overview of the DOE-2 building energy analysis program, version 2.1D; Feb.
    • Birdsall B, Buhl WF, Ellington KL, Erdem AE, Winkelmann FC. (DOE2 90) LBL-19735, Rev. 1 Overview of the DOE-2 building energy analysis program, version 2.1D; Feb. 1990.
    • (1990)
    • Birdsall, B.1    Buhl, W.F.2    Ellington, K.L.3    Erdem, A.E.4    Winkelmann, F.C.5
  • 17
    • 84919398084 scopus 로고    scopus 로고
    • Comprehensive investigations of life cycle climate performance of packaged air source heat pumps for residential application
    • Li G. Comprehensive investigations of life cycle climate performance of packaged air source heat pumps for residential application. Renew Sustain Energy Rev 2015, 43:702-710.
    • (2015) Renew Sustain Energy Rev , vol.43 , pp. 702-710
    • Li, G.1
  • 18
    • 84890567057 scopus 로고    scopus 로고
    • Effect of the header pressure drop induced flow maldistribution on the microchannel evaporator performance
    • Tuo H., Hrnjak P. Effect of the header pressure drop induced flow maldistribution on the microchannel evaporator performance. Int J Refrig 2013, 36(8):2176-2186.
    • (2013) Int J Refrig , vol.36 , Issue.8 , pp. 2176-2186
    • Tuo, H.1    Hrnjak, P.2
  • 19
    • 84890567747 scopus 로고    scopus 로고
    • New approach to improve performance by venting periodic reverse vapor flow in microchannel evaporator
    • Tuo H., Hrnjak P. New approach to improve performance by venting periodic reverse vapor flow in microchannel evaporator. Int J Refrig 2013, 36:2187-2195.
    • (2013) Int J Refrig , vol.36 , pp. 2187-2195
    • Tuo, H.1    Hrnjak, P.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.