메뉴 건너뛰기




Volumn 24, Issue 2, 2017, Pages 1239-1248

Dissolved gas analysis evaluation in electric power transformers using conventional methods a review

Author keywords

dissolved gas analysis Duval triangle; fault diagnosis; Power transformers

Indexed keywords

DISSOLUTION; FAILURE ANALYSIS; GAS CHROMATOGRAPHY; OUTAGES; POWER TRANSFORMERS; THERMAL INSULATION;

EID: 85018322610     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/TDEI.2017.005959     Document Type: Article
Times cited : (229)

References (28)
  • 1
    • 84862696848 scopus 로고    scopus 로고
    • A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis
    • A. Abu-Siada and S. Islam, "A new approach to identify power transformer criticality and asset management decision based on dissolved gas-in-oil analysis, " IEEE Trans. Dielectr. Electr. Insul., Vol. 19, No. 3, pp. 1007-1012, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul , vol.19 , Issue.3 , pp. 1007-1012
    • Abu-Siada, A.1    Islam, S.2
  • 2
    • 84878474087 scopus 로고    scopus 로고
    • Dissolved gas analysis of mineral oil for power transformer fault diagnosis using fuzzy logic
    • Y. C. Huang and H. C. Sun, "Dissolved gas analysis of mineral oil for power transformer fault diagnosis using fuzzy logic, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 3, pp. 974-981, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.3 , pp. 974-981
    • Huang, Y.C.1    Sun, H.C.2
  • 3
    • 84898446179 scopus 로고    scopus 로고
    • Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer
    • M. Yang and L. Hu, "Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 6, pp. 2317-2324, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.6 , pp. 2317-2324
    • Yang, M.1    Hu, L.2
  • 4
    • 0344465271 scopus 로고    scopus 로고
    • Review of modern diagnostic techniques for assessing insulation condition in aged transformers
    • T. K. Saha, "Review of Modern Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers, " IEEE Trans. Dielectr. Electr. Insul., Vol. 10, No. 5, pp. 903-917, 2003.
    • (2003) IEEE Trans. Dielectr. Electr. Insul , vol.10 , Issue.5 , pp. 903-917
    • Saha, T.K.1
  • 5
    • 84898446179 scopus 로고    scopus 로고
    • Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer
    • M. T. Yang and L. S. Hu, "Intelligent fault types diagnostic system for dissolved gas analysis of oil-immersed power transformer, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 6, pp. 2317-2324, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.6 , pp. 2317-2324
    • Yang, M.T.1    Hu, L.S.2
  • 6
    • 84924906210 scopus 로고    scopus 로고
    • A review of monitoring methods for predictive maintenance of electric power transformers based on dissolved gas analysis
    • H. de Faria, J. G. S. Costa, and J. L. M. Olivas, "A review of monitoring methods for predictive maintenance of electric power transformers based on dissolved gas analysis, " Renew. Sustain. Energy Rev., Vol. 46, pp. 201-209, 2015.
    • (2015) Renew. Sustain. Energy Rev , vol.46 , pp. 201-209
    • De Faria, H.1    Costa, J.G.S.2    Olivas, J.L.M.3
  • 7
    • 84899877251 scopus 로고    scopus 로고
    • A review of dissolved gas analysis measurement and interpretation techniques
    • N. A. Bakar, A. Abu-Siada and S. Islam, "A review of dissolved gas analysis measurement and interpretation techniques, " IEEE Electr. Insul. Mag., Vol. 30, No. 3, pp. 39-49, 2014.
    • (2014) IEEE Electr. Insul. Mag , vol.30 , Issue.3 , pp. 39-49
    • Bakar, N.A.1    Abu-Siada, A.2    Islam, S.3
  • 8
    • 84923163692 scopus 로고    scopus 로고
    • A comprehensive comparative study of DGA based transformer fault diagnosis using fuzzy logic and ANFIS models
    • S. A. Khan, M. D. Equbal and T. Islam, "A comprehensive comparative study of DGA based transformer fault diagnosis using fuzzy logic and ANFIS models, " IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 1, pp. 590-596, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul , vol.22 , Issue.1 , pp. 590-596
    • Khan, S.A.1    Equbal, M.D.2    Islam, T.3
  • 9
    • 84982295628 scopus 로고    scopus 로고
    • Integrated ANN-based proactive fault diagnostic scheme for power transformers using dissolved gas analysis
    • S. S. M. Ghoneim, I. B. M. Taha and N. I. Elkalashy, "Integrated ANN-based proactive fault diagnostic scheme for power transformers using dissolved gas analysis, " IEEE Trans. Dielectr. Electr. Insul., Vol. 23, No. 3, pp. 1838-1845, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul , vol.23 , Issue.3 , pp. 1838-1845
    • Ghoneim, S.S.M.1    Taha, I.B.M.2    Elkalashy, N.I.3
  • 10
    • 84963796013 scopus 로고    scopus 로고
    • Interpretation of DGA for transformer fault diagnosis with complementary SaE-ELM and arctangent transform
    • S. Li, G. Wu, B. Gao, C. Hao, D. Xin and X. Yin, "Interpretation of DGA for transformer fault diagnosis with complementary SaE-ELM and arctangent transform, " IEEE Trans. Dielectr. Electr. Insul., Vol. 23, No. l, pp. 586-595, 2016.
    • (2016) IEEE Trans. Dielectr. Electr. Insul , vol.23 , Issue.1 , pp. 586-595
    • Li, S.1    Wu, G.2    Gao, B.3    Hao, C.4    Xin, D.5    Yin, X.6
  • 11
    • 58249139750 scopus 로고    scopus 로고
    • Wavelet networks in power transformers diagnosis using dissolved gas analysis
    • W. Chen, C. Pan, Y. Yun and Y. Liu, "Wavelet networks in power transformers diagnosis using dissolved gas analysis, " IEEE Trans. Power Deliv., Vol. 24, No. 1, pp. 187-194, 2009.
    • (2009) IEEE Trans. Power Deliv , vol.24 , Issue.1 , pp. 187-194
    • Chen, W.1    Pan, C.2    Yun, Y.3    Liu, Y.4
  • 12
    • 84907554786 scopus 로고    scopus 로고
    • Investigations into the stray gassing of oils in the fault diagnosis of transformers
    • D. Martin, N. Lelekakis, J. Wijaya, M. Duval, and L. Fellow, "Investigations into the stray gassing of oils in the fault diagnosis of transformers, " IEEE Trans. Power Deliv., Vol. 29, No. 5, pp. 23692374, 2014.
    • (2014) IEEE Trans. Power Deliv , vol.29 , Issue.5 , pp. 23692374
    • Martin, D.1    Lelekakis, N.2    Wijaya, J.3    Duval, M.4    Fellow, L.5
  • 13
    • 84961938171 scopus 로고    scopus 로고
    • Analysis of excessive hydrogen generation in transformers in service
    • T. Piotrowski and P. Rozga, "Analysis of excessive hydrogen generation in transformers in service, " IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 6, pp. 3600-3607, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul , vol.22 , Issue.6 , pp. 3600-3607
    • Piotrowski, T.1    Rozga, P.2
  • 14
    • 85018346155 scopus 로고    scopus 로고
    • Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids under Thermal Stress
    • Standard Test Method for the Determination of Gassing Characteristics of Insulating Liquids Under Thermal Stress, ASTM D7150, 2013.
    • (2013) ASTM D7150
  • 15
    • 0016057142 scopus 로고
    • Monitoring oil-cooled transformers by gas-Analysis
    • E. Dornenburg and W. Strittma, "Monitoring oil-cooled transformers by gas-Analysis, " Brown Boveri Rev., Vol. 61, No. 5, pp. 238-247, 1974.
    • (1974) Brown Boveri Rev , vol.61 , Issue.5 , pp. 238-247
    • Dornenburg, E.1    Strittma, W.2
  • 18
    • 0018021576 scopus 로고
    • Ieee and iec codes to interpret faults in transformers, using gas in oil analysis
    • R. R. Rogers, "IEEE and IEC Codes to Interpret Faults in Transformers, using Gas in Oil Analysis, " IEEE Trans. Electr. Insul., Vol. 75, No. 5, pp. 349-354, 1978.
    • (1978) IEEE Trans. Electr. Insul , vol.75 , Issue.5 , pp. 349-354
    • Rogers, R.R.1
  • 19
    • 0019079773 scopus 로고
    • Transformer fault diagnosis by dissolved-gas analysis
    • J. J. Kelly, "Transformer fault diagnosis by dissolved-gas analysis, " IEEE Trans. Ind. Appl., Vol. IA-16, No. 6, pp. 777-782, 1980.
    • (1980) IEEE Trans. Ind. Appl , vol.16 , Issue.6 , pp. 777-782
    • Kelly, J.J.1
  • 21
    • 0036564344 scopus 로고    scopus 로고
    • A Review of faults detectable by gas-in-oil analysis in transformers
    • M. Duval, "A Review of faults detectable by gas-in-oil analysis in transformers, " IEEE Elect. Insul. Mag., Vol. 18, No. 3, pp. 8-17, 2002.
    • (2002) IEEE Elect. Insul. Mag , vol.18 , Issue.3 , pp. 8-17
    • Duval, M.1
  • 22
    • 57849136556 scopus 로고    scopus 로고
    • The duval triangle for load tap changers , non-mineral oils and Low
    • M. Duval, "The duval triangle for load tap changers , non-mineral oils and Low, " IEEE Elect. Insul. Mag., Vol. 24, No. 6, pp. 22-29, 2008.
    • (2008) IEEE Elect. Insul. Mag , vol.24 , Issue.6 , pp. 22-29
    • Duval, M.1
  • 23
    • 84872082133 scopus 로고    scopus 로고
    • A new graphical technique for the interpretation of dissolved gas analysis in power transformers
    • D. A. Mansour, "A new graphical technique for the interpretation of dissolved gas analysis in power transformers, " IEEE Conf. Electr. Insul. Dielectr. Phenom., pp. 195-198, 2012.
    • (2012) IEEE Conf. Electr. Insul. Dielectr. Phenom , pp. 195-198
    • Mansour, D.A.1
  • 24
    • 84947902062 scopus 로고    scopus 로고
    • Development of a new graphical technique for dissolved gas analysis in power transformers based on the five combustible gases
    • D. A. Mansour, "Development of a new graphical technique for dissolved gas analysis in power transformers based on the five combustible gases, " IEEE Trans. Dielectr. Electr. Insul., Vol. 22, No. 5, pp. 2507-2512, 2015.
    • (2015) IEEE Trans. Dielectr. Electr. Insul , vol.22 , Issue.5 , pp. 2507-2512
    • Mansour, D.A.1
  • 25
    • 84908667321 scopus 로고    scopus 로고
    • The Duval pentagon-A new complementary tool for the interpretation of dissolved gas analysis in transformers
    • M. Duval and L. Lamarre, "The Duval pentagon-A new complementary tool for the interpretation of dissolved gas analysis in transformers, " IEEE Electr. Insul. Mag., Vol. 30, No. 6, pp. 9-12, 2014.
    • (2014) IEEE Electr. Insul. Mag , vol.30 , Issue.6 , pp. 9-12
    • Duval, M.1    Lamarre, L.2
  • 26
    • 84898445845 scopus 로고    scopus 로고
    • A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis
    • A. Abu-Siada, S. Hmood, and S. Islam, "A new fuzzy logic approach for consistent interpretation of dissolved gas-in-oil analysis, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 6, pp. 2343-2349, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.6 , pp. 2343-2349
    • Abu-Siada, A.1    Hmood, S.2    Islam, S.3
  • 27
    • 84877292291 scopus 로고    scopus 로고
    • New methods of DGA diagnosis using IEC TC 10 and related databases Part 1 : Application of gas-ratio combinations
    • S. Kim, S. Kim, H. Seo, J. Jung, and H. Yang, "New methods of DGA diagnosis using IEC TC 10 and related databases Part 1 : Application of gas-ratio combinations, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 2, pp. 685-690, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.2 , pp. 685-690
    • Kim, S.1    Kim, S.2    Seo, H.3    Jung, J.4    Yang, H.5
  • 28
    • 84877291582 scopus 로고    scopus 로고
    • New methods of DGA diagnosis using IEC TC 10 and related databases Part 2: Application of relative content of fault gases
    • S. Lee, Y. Kim, H. Seo, J. Jung, and H. Yang, "New methods of DGA diagnosis using IEC TC 10 and related databases Part 2: Application of relative content of fault gases, " IEEE Trans. Dielectr. Electr. Insul., Vol. 20, No. 2, pp. 691-696, 2013.
    • (2013) IEEE Trans. Dielectr. Electr. Insul , vol.20 , Issue.2 , pp. 691-696
    • Lee, S.1    Kim, Y.2    Seo, H.3    Jung, J.4    Yang, H.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.