1
-
-
0035481368
-
A comparative study of neural network efficiency in power transformers diagnosis using dissolved gas analysis
-
L. Guardado, J.L. Naredo, P. Moreno, and C.R. Fuerte, "A comparative study of neural network efficiency in power transformers diagnosis using dissolved gas analysis", IEEE Trans. Power Delivery, Vol. 16, pp. 643-647, 2001.
-
(2001)
IEEE Trans. Power Delivery
, vol.16
, pp. 643-647
-
-
Guardado, L.1
Naredo, J.L.2
Moreno, P.3
Fuerte, C.R.4
-
2
-
-
0036564344
-
A review of faults detectable by gas-in-oil analysis in transformers
-
M. Duval, "A review of faults detectable by gas-in-oil analysis in transformers", IEEE Electr. Insul. Mag., Vol. 18, No.3, pp. 8-17, 2002.
-
(2002)
IEEE Electr. Insul. Mag
, vol.18
, Issue.3
, pp. 8-17
-
-
Duval, M.1
-
3
-
-
25444527545
-
Improving the reliability of transformer gas-in-oil diagnosis
-
M. Duval, and J. Dukarm, "Improving the reliability of transformer gas-in-oil diagnosis", IEEE Electr. Insul. Mag., Vol. 21, No. 4, pp. 21-27, 2005.
-
(2005)
IEEE Electr. Insul. Mag
, vol.21
, Issue.4
, pp. 21-27
-
-
Duval, M.1
Dukarm, J.2
-
4
-
-
84870604062
-
Gassing characteristics of transformer oil under thermal stress
-
Available
-
L. R. Lewand, and P. Griffin, "Gassing characteristics of transformer oil under thermal stress", NETA World, The Official Publication of the Int. Electrical Testing Association, pp. 1-4, 2005, Available: http://www.netaworld.org/netaworld-journal/archived-articles/377
-
(2005)
NETA World, the Official Publication of the Int. Electrical Testing Association
, pp. 1-4
-
-
Lewand, L.R.1
Griffin, P.2
-
6
-
-
33947280106
-
Unusual cases of gassing in transformers in service
-
I. Hohlein, "Unusual cases of gassing in transformers in service", IEEE Electr. Insul. Mag., Vol. 22, No. 1, pp. 24-27, 2006.
-
(2006)
IEEE Electr. Insul. Mag
, vol.22
, Issue.1
, pp. 24-27
-
-
Hohlein, I.1
-
7
-
-
84961963445
-
-
Recent developments in DGA interpretation
-
Recent developments in DGA interpretation, CIGRE Technical Brochure No. 296, 2006.
-
(2006)
CIGRE Technical Brochure
, Issue.296
-
-
-
10
-
-
57849136556
-
The Duval triangle for load tap changers, non-mineral oils and low temperature faults in transformers
-
M. Duval, "The Duval triangle for load tap changers, non-mineral oils and low temperature faults in transformers," IEEE Electr. Insul. Mag., Vol. 24, No. 6, pp. 22-29, 2008.
-
(2008)
IEEE Electr. Insul. Mag
, vol.24
, Issue.6
, pp. 22-29
-
-
Duval, M.1
-
11
-
-
84862262281
-
Canonical correlation between partial discharges and gas formation in transformer oil paper insulation
-
W. Chen, X. Chen, S. Peng, and J. Li, "Canonical correlation between partial discharges and gas formation in transformer oil paper insulation", Energies, Vol. 5, pp. 1081-1097, 2012.
-
(2012)
Energies
, vol.5
, pp. 1081-1097
-
-
Chen, W.1
Chen, X.2
Peng, S.3
Li, J.4
-
12
-
-
84961911196
-
-
Framework Instruction of Transformer Operation, Energopomiar-Elektryka, Gliwice, Poland in Polish
-
Framework Instruction of Transformer Operation, Energopomiar-Elektryka, Gliwice, Poland, 2012. (in Polish)
-
(2012)
-
-
-
13
-
-
84872131059
-
Unusual ethylene production of in-service transformer oil at low temperature
-
S. Besner, J. Jalbert, and B. Noirhomme, "Unusual ethylene production of in-service transformer oil at low temperature", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, pp. 1901-1907, 2012.
-
(2012)
IEEE Trans. Dielectr. Electr. Insul
, vol.19
, pp. 1901-1907
-
-
Besner, S.1
Jalbert, J.2
Noirhomme, B.3
-
14
-
-
33645750935
-
A hybrid tool for detection of incipient faults in transformers based on the dissolved gas analysis of insulating oil
-
J.R. Rolim, and D.R. Morais, "A hybrid tool for detection of incipient faults in transformers based on the dissolved gas analysis of insulating oil", IEEE Trans. Power Delivery, Vol. 21, pp. 673-680, 2006.
-
(2006)
IEEE Trans. Power Delivery
, vol.21
, pp. 673-680
-
-
Rolim, J.R.1
Morais, D.R.2
-
15
-
-
0035415135
-
Identification of specific type of PD from acoustic emission frequency spectra
-
T. Boczar, "Identification of specific type of PD from acoustic emission frequency spectra", IEEE Trans. Diel. Electr. Insul., Vol. 8, pp. 598-606, 2001.
-
(2001)
IEEE Trans. Diel. Electr. Insul
, vol.8
, pp. 598-606
-
-
Boczar, T.1
-
16
-
-
55149124192
-
Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform
-
Ch. Li-Jung, L. Whei-Min, T. Ta-Peng, and L. Yu-Hsun, "Study of partial discharge measurement in power equipment using acoustic technique and wavelet transform", IEEE Trans. Power Delivery, Vol. 22, pp. 1575-1580, 2007.
-
(2007)
IEEE Trans. Power Delivery
, vol.22
, pp. 1575-1580
-
-
Li-Jung, C.1
Whei-Min, L.2
Ta-Peng, T.3
Yu-Hsun, L.4
-
17
-
-
84898682373
-
Diagnostic expert system of transformer insulation systems using acoustic emission method
-
T. Boczar, A. Cichon, and S. Borucki, "Diagnostic expert system of transformer insulation systems using acoustic emission method", IEEE Trans. Dielectr. Electr. Insul., Vol. 21, pp. 854-865, 2014.
-
(2014)
IEEE Trans. Dielectr. Electr. Insul
, vol.21
, pp. 854-865
-
-
Boczar, T.1
Cichon, A.2
Borucki, S.3
|