메뉴 건너뛰기




Volumn 97, Issue 1, 2016, Pages 91-99

Shear wave elastography: An accurate technique to stage liver fibrosis in chronic liver diseases

Author keywords

Cirrhosis; Elasticity imaging techniques; Elastography; Liver fibrosis; Sonoelastography

Indexed keywords

ADULT; ARTICLE; CHRONIC LIVER DISEASE; CONTROLLED STUDY; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; EVALUATION STUDY; FATTY LIVER; FEMALE; HISTOPATHOLOGY; HUMAN; HUMAN TISSUE; LIVER BIOPSY; LIVER CIRRHOSIS; LIVER FIBROSIS; LIVER STIFFNESS; MAJOR CLINICAL STUDY; MALE; MORPHOMETRY; PREDICTIVE VALUE; PROSPECTIVE STUDY; REAL TIME ULTRASOUND SCANNER; SENSITIVITY AND SPECIFICITY; SHEAR WAVE ELASTOGRAPHY; STAGING; TRANSIENT ELASTOGRAPHY; CHRONIC DISEASE; COMPARATIVE STUDY; COMPLICATION; DIAGNOSTIC IMAGING; ELASTOGRAPHY; LIVER DISEASE; MIDDLE AGED; PATHOLOGY; REPRODUCIBILITY; SEVERITY OF ILLNESS INDEX;

EID: 85017056195     PISSN: None     EISSN: 22115684     Source Type: Journal    
DOI: 10.1016/j.diii.2015.11.001     Document Type: Article
Times cited : (60)

References (35)
  • 1
    • 77951083787 scopus 로고    scopus 로고
    • Prevalence of liver fibrosis and risk factors in a general population using non-invasive biomarkers (FibroTest)
    • Poynard, T., Lebray, P., Ingiliz, P., et al. Prevalence of liver fibrosis and risk factors in a general population using non-invasive biomarkers (FibroTest). BMC Gastroenterol, 10, 2010, 40.
    • (2010) BMC Gastroenterol , vol.10 , pp. 40
    • Poynard, T.1    Lebray, P.2    Ingiliz, P.3
  • 3
    • 0022656928 scopus 로고
    • Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver
    • Maharaj, B., Maharaj, R.J., Leary, W.P., et al. Sampling variability and its influence on the diagnostic yield of percutaneous needle biopsy of the liver. Lancet 1 (1986), 523–525.
    • (1986) Lancet , vol.1 , pp. 523-525
    • Maharaj, B.1    Maharaj, R.J.2    Leary, W.P.3
  • 4
    • 84979834108 scopus 로고    scopus 로고
    • Ultrasonographic assessment of liver fibrosis with computer-assisted analysis of liver surface irregularities
    • Huet, N., Denis, I., Martino, A., Gallix, B., Sturm, N., Leroy, V., et al. Ultrasonographic assessment of liver fibrosis with computer-assisted analysis of liver surface irregularities. Diagn Interv Imaging 96 (2015), 941–946.
    • (2015) Diagn Interv Imaging , vol.96 , pp. 941-946
    • Huet, N.1    Denis, I.2    Martino, A.3    Gallix, B.4    Sturm, N.5    Leroy, V.6
  • 5
    • 55549095101 scopus 로고    scopus 로고
    • Assessment of liver fibrosis using transient elastography in patients with alcoholic liver disease
    • Nahon, P., Kettaneh, A., Tengher-Barna, I., et al. Assessment of liver fibrosis using transient elastography in patients with alcoholic liver disease. J Hepatol 49 (2008), 1062–1068.
    • (2008) J Hepatol , vol.49 , pp. 1062-1068
    • Nahon, P.1    Kettaneh, A.2    Tengher-Barna, I.3
  • 6
    • 84856968669 scopus 로고    scopus 로고
    • Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD
    • Friedrich-Rust, M., Romen, D., Vermehren, J., et al. Acoustic radiation force impulse-imaging and transient elastography for non-invasive assessment of liver fibrosis and steatosis in NAFLD. Eur J Radiol 81 (2012), e325–e331.
    • (2012) Eur J Radiol , vol.81 , pp. e325-e331
    • Friedrich-Rust, M.1    Romen, D.2    Vermehren, J.3
  • 7
    • 33646557347 scopus 로고    scopus 로고
    • Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC
    • Corpechot, C., El Naggar, A., Poujol-Robert, A., et al. Assessment of biliary fibrosis by transient elastography in patients with PBC and PSC. Hepatology 43 (2006), 1118–1124.
    • (2006) Hepatology , vol.43 , pp. 1118-1124
    • Corpechot, C.1    El Naggar, A.2    Poujol-Robert, A.3
  • 8
    • 77950619459 scopus 로고    scopus 로고
    • Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations
    • Castera, L., Foucher, J., Bernard, P.H., et al. Pitfalls of liver stiffness measurement: a 5-year prospective study of 13,369 examinations. Hepatology 51 (2010), 828–835.
    • (2010) Hepatology , vol.51 , pp. 828-835
    • Castera, L.1    Foucher, J.2    Bernard, P.H.3
  • 9
    • 84863988049 scopus 로고    scopus 로고
    • ARFI, FibroScan, ELF, and their combinations in the assessment of liver fibrosis: a prospective study
    • Crespo, G., Fernandez-Varo, G., Marino, Z., et al. ARFI, FibroScan, ELF, and their combinations in the assessment of liver fibrosis: a prospective study. J Hepatol 57 (2012), 281–287.
    • (2012) J Hepatol , vol.57 , pp. 281-287
    • Crespo, G.1    Fernandez-Varo, G.2    Marino, Z.3
  • 10
    • 84892578077 scopus 로고    scopus 로고
    • Ultrasound elastography in liver
    • Frulio, N., Trillaud, H., Ultrasound elastography in liver. Diagn Interv Imaging 94 (2013), 515–534.
    • (2013) Diagn Interv Imaging , vol.94 , pp. 515-534
    • Frulio, N.1    Trillaud, H.2
  • 13
    • 25444434632 scopus 로고    scopus 로고
    • Hepascore: an accurate validated predictor of liver fibrosis in chronic hepatitis C infection
    • Adams, L.A., Bulsara, M., Rossi, E., et al. Hepascore: an accurate validated predictor of liver fibrosis in chronic hepatitis C infection. Clin Chem 51 (2005), 1867–1873.
    • (2005) Clin Chem , vol.51 , pp. 1867-1873
    • Adams, L.A.1    Bulsara, M.2    Rossi, E.3
  • 14
    • 84870530814 scopus 로고    scopus 로고
    • Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study
    • Ferraioli, G., Tinelli, C., Dal Bello, B., Zicchetti, M., Filice, G., Filice, C., Accuracy of real-time shear wave elastography for assessing liver fibrosis in chronic hepatitis C: a pilot study. Hepatology 56 (2012), 2125–2133.
    • (2012) Hepatology , vol.56 , pp. 2125-2133
    • Ferraioli, G.1    Tinelli, C.2    Dal Bello, B.3    Zicchetti, M.4    Filice, G.5    Filice, C.6
  • 15
    • 84888790657 scopus 로고    scopus 로고
    • Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: comparison of shear-wave elastography and transient elastography with liver biopsy correlation
    • Leung, V.Y., Shen, J., Wong, V.W., et al. Quantitative elastography of liver fibrosis and spleen stiffness in chronic hepatitis B carriers: comparison of shear-wave elastography and transient elastography with liver biopsy correlation. Radiology 269 (2013), 910–918.
    • (2013) Radiology , vol.269 , pp. 910-918
    • Leung, V.Y.1    Shen, J.2    Wong, V.W.3
  • 16
    • 84876289848 scopus 로고    scopus 로고
    • Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard
    • Poynard, T., Munteanu, M., Luckina, E., Perazzo, H., Ngo, Y., Royer, L., et al. Liver fibrosis evaluation using real-time shear wave elastography: applicability and diagnostic performance using methods without a gold standard. J Hepatol 58 (2013), 928–935.
    • (2013) J Hepatol , vol.58 , pp. 928-935
    • Poynard, T.1    Munteanu, M.2    Luckina, E.3    Perazzo, H.4    Ngo, Y.5    Royer, L.6
  • 18
    • 0029778988 scopus 로고    scopus 로고
    • An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group
    • Bedossa, P., Poynard, T., An algorithm for the grading of activity in chronic hepatitis C. The METAVIR Cooperative Study Group. Hepatology 24 (1996), 289–293.
    • (1996) Hepatology , vol.24 , pp. 289-293
    • Bedossa, P.1    Poynard, T.2
  • 19
    • 20044374023 scopus 로고    scopus 로고
    • Design and validation of a histological scoring system for nonalcoholic fatty liver disease
    • Kleiner, D.E., Brunt, E.M., Van Natta, M., et al. Design and validation of a histological scoring system for nonalcoholic fatty liver disease. Hepatology 41 (2005), 1313–1321.
    • (2005) Hepatology , vol.41 , pp. 1313-1321
    • Kleiner, D.E.1    Brunt, E.M.2    Van Natta, M.3
  • 20
    • 84860299294 scopus 로고    scopus 로고
    • Noninvasive methods to assess liver disease in patients with hepatitis B or C
    • Castera, L., Noninvasive methods to assess liver disease in patients with hepatitis B or C. Gastroenterology 142 (2012), 1293–1302.
    • (2012) Gastroenterology , vol.142 , pp. 1293-1302
    • Castera, L.1
  • 21
    • 0032031620 scopus 로고    scopus 로고
    • Histopathological evaluation of liver fibrosis: quantitative image analysis vs. semi-quantitative scores. Comparison with serum markers
    • Pilette, C., Rousselet, M.C., Bedossa, P., et al. Histopathological evaluation of liver fibrosis: quantitative image analysis vs. semi-quantitative scores. Comparison with serum markers. J Hepatol 28 (1998), 439–446.
    • (1998) J Hepatol , vol.28 , pp. 439-446
    • Pilette, C.1    Rousselet, M.C.2    Bedossa, P.3
  • 22
    • 48949098875 scopus 로고    scopus 로고
    • How to measure the diagnostic accuracy of noninvasive liver fibrosis indices: the area under the ROC curve revisited
    • Lambert, J., Halfon, P., Penaranda, G., Bedossa, P., Cacoub, P., Carrat, F., How to measure the diagnostic accuracy of noninvasive liver fibrosis indices: the area under the ROC curve revisited. Clin Chem 54 (2008), 1372–1378.
    • (2008) Clin Chem , vol.54 , pp. 1372-1378
    • Lambert, J.1    Halfon, P.2    Penaranda, G.3    Bedossa, P.4    Cacoub, P.5    Carrat, F.6
  • 23
    • 23844462235 scopus 로고    scopus 로고
    • Estimating and comparing diagnostic tests’ accuracy when the gold standard is not binary
    • Obuchowski, N.A., Estimating and comparing diagnostic tests’ accuracy when the gold standard is not binary. Acad Radiol 12 (2005), 1198–1204.
    • (2005) Acad Radiol , vol.12 , pp. 1198-1204
    • Obuchowski, N.A.1
  • 24
    • 83155181614 scopus 로고    scopus 로고
    • FibroTest and Fibroscan performances revisited in patients with chronic hepatitis C. Impact of the spectrum effect and the applicability rate
    • Poynard, T., de Ledinghen, V., Zarski, J.P., et al. FibroTest and Fibroscan performances revisited in patients with chronic hepatitis C. Impact of the spectrum effect and the applicability rate. Clin Res Hepatol Gastroenterol 35 (2011), 720–730.
    • (2011) Clin Res Hepatol Gastroenterol , vol.35 , pp. 720-730
    • Poynard, T.1    de Ledinghen, V.2    Zarski, J.P.3
  • 26
    • 0019978521 scopus 로고
    • The extracellular matrix of the liver
    • Rojkind, M., Ponce-Noyola, P., The extracellular matrix of the liver. Coll Relat Res 2 (1982), 151–175.
    • (1982) Coll Relat Res , vol.2 , pp. 151-175
    • Rojkind, M.1    Ponce-Noyola, P.2
  • 27
    • 34447557853 scopus 로고    scopus 로고
    • Diagnosis of hepatic steatosis and fibrosis by transient elastography in asymptomatic healthy individuals: a prospective study of living related potential liver donors
    • Kim, K.M., Choi, W.B., Park, S.H., et al. Diagnosis of hepatic steatosis and fibrosis by transient elastography in asymptomatic healthy individuals: a prospective study of living related potential liver donors. J Gastroenterol 42 (2007), 382–388.
    • (2007) J Gastroenterol , vol.42 , pp. 382-388
    • Kim, K.M.1    Choi, W.B.2    Park, S.H.3
  • 28
    • 41849148981 scopus 로고    scopus 로고
    • Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with nonalcoholic fatty liver disease (NAFLD)
    • Yoneda, M., Yoneda, M., Mawatari, H., et al. Noninvasive assessment of liver fibrosis by measurement of stiffness in patients with nonalcoholic fatty liver disease (NAFLD). Dig Liver Dis 40 (2008), 371–378.
    • (2008) Dig Liver Dis , vol.40 , pp. 371-378
    • Yoneda, M.1    Yoneda, M.2    Mawatari, H.3
  • 29
    • 84878733008 scopus 로고    scopus 로고
    • Shear wave elastography in the evaluation of rejection or recurrent hepatitis after liver transplantation
    • Yoon, J.H., Lee, J.Y., Woo, H.S., et al. Shear wave elastography in the evaluation of rejection or recurrent hepatitis after liver transplantation. Eur Radiol 23 (2013), 1729–1737.
    • (2013) Eur Radiol , vol.23 , pp. 1729-1737
    • Yoon, J.H.1    Lee, J.Y.2    Woo, H.S.3
  • 30
    • 39549105171 scopus 로고    scopus 로고
    • Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage
    • Sagir, A., Erhardt, A., Schmitt, M., Haussinger, D., Transient elastography is unreliable for detection of cirrhosis in patients with acute liver damage. Hepatology 47 (2008), 592–595.
    • (2008) Hepatology , vol.47 , pp. 592-595
    • Sagir, A.1    Erhardt, A.2    Schmitt, M.3    Haussinger, D.4
  • 31
    • 73949123503 scopus 로고    scopus 로고
    • Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results
    • Lupsor, M., Badea, R., Stefanescu, H., et al. Performance of a new elastographic method (ARFI technology) compared to unidimensional transient elastography in the noninvasive assessment of chronic hepatitis C. Preliminary results. J Gastrointestin Liver Dis 18 (2009), 303–310.
    • (2009) J Gastrointestin Liver Dis , vol.18 , pp. 303-310
    • Lupsor, M.1    Badea, R.2    Stefanescu, H.3
  • 32
    • 84867024277 scopus 로고    scopus 로고
    • Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity
    • Ferraioli, G., Tinelli, C., Zicchetti, M., et al. Reproducibility of real-time shear wave elastography in the evaluation of liver elasticity. Eur J Radiol 81 (2012), 3102–3106.
    • (2012) Eur J Radiol , vol.81 , pp. 3102-3106
    • Ferraioli, G.1    Tinelli, C.2    Zicchetti, M.3
  • 33
    • 79954526933 scopus 로고    scopus 로고
    • Transient elastography as a screening tool for liver fibrosis and cirrhosis in a community-based population aged over 45 years
    • Roulot, D., Costes, J.L., Buyck, J.F., et al. Transient elastography as a screening tool for liver fibrosis and cirrhosis in a community-based population aged over 45 years. Gut 60 (2011), 977–984.
    • (2011) Gut , vol.60 , pp. 977-984
    • Roulot, D.1    Costes, J.L.2    Buyck, J.F.3
  • 34
    • 84922238825 scopus 로고    scopus 로고
    • Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography
    • Deffieux, T., Gennisson, J.L., Bousquet, L., et al. Investigating liver stiffness and viscosity for fibrosis, steatosis and activity staging using shear wave elastography. J Hepatol 62 (2015), 317–324.
    • (2015) J Hepatol , vol.62 , pp. 317-324
    • Deffieux, T.1    Gennisson, J.L.2    Bousquet, L.3
  • 35
    • 7244250409 scopus 로고    scopus 로고
    • Silent non-alcoholic fatty liver disease – a clinical-histological study
    • Sorrentino, P., Tarantino, G., Conca, P., et al. Silent non-alcoholic fatty liver disease – a clinical-histological study. J Hepatol 41 (2004), 751–757.
    • (2004) J Hepatol , vol.41 , pp. 751-757
    • Sorrentino, P.1    Tarantino, G.2    Conca, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.