메뉴 건너뛰기




Volumn 3, Issue , 2010, Pages 159-167

Are adrenaline autoinjectors fit for purpose? A pilot study of the mechanical and injection performance characteristics of a cartridgeversus a syringe-based autoinjector

Author keywords

Anaphylaxis; Delivery system; Device; Intramuscular

Indexed keywords


EID: 85016103834     PISSN: None     EISSN: 11786965     Source Type: Journal    
DOI: 10.2147/JAA.S14419     Document Type: Article
Times cited : (17)

References (13)
  • 1
    • 34447118863 scopus 로고    scopus 로고
    • The management of anaphylaxis in childhood: A position paper of the European academy of allergology and clinical immunology
    • for the EACCI Task Force on Anaphylaxis in Children
    • Muraro A, Roberts G, Clark A, et al; for the EACCI Task Force on Anaphylaxis in Children. The management of anaphylaxis in childhood: a position paper of the European academy of allergology and clinical immunology. Allergy. 2007;62:857-871.
    • (2007) Allergy , vol.62 , pp. 857-871
    • Muraro, A.1    Roberts, G.2    Clark, A.3
  • 3
    • 85022188773 scopus 로고    scopus 로고
    • Resuscitation Council UK. Emergency treatment of anaphylactic reactions. Guidelines for healthcare providers. Available from, Accessed, Oct 1
    • Resuscitation Council UK. Emergency treatment of anaphylactic reactions. Guidelines for healthcare providers. Available from: http://www.resus.org.uk/pages/reaction.pdf. Accessed 2010 Oct 1.
    • (2010)
  • 4
    • 56149100176 scopus 로고    scopus 로고
    • Paediatric anaphylaxis: A 5 year retrospective review
    • de Silva IL, Mehr SS, Tey D, Tang ML. Paediatric anaphylaxis: a 5 year retrospective review. Allergy. 2008;63:1071-1076.
    • (2008) Allergy , vol.63 , pp. 1071-1076
    • De Silva, I.L.1    Mehr, S.S.2    Tey, D.3    Tang, M.L.4
  • 5
    • 33947721061 scopus 로고    scopus 로고
    • Finger injection with highdose (1:1, 000) epinephrine: Does it cause finger necrosis and should it be treated?
    • Fitzcharles-Bowe C, Denkler K, Lalonde D. Finger injection with highdose (1:1, 000) epinephrine: does it cause finger necrosis and should it be treated? Hand (NY). 2007;2:5-11.
    • (2007) Hand (NY) , vol.2 , pp. 5-11
    • Fitzcharles-Bowe, C.1    Denkler, K.2    Lalonde, D.3
  • 6
    • 65249188740 scopus 로고    scopus 로고
    • Hazards of unintentional injection of epinephrine from auto-injectors: A systematic review
    • Simons FER, Lieberman PL, Read EJ Jr, Edwards ES. Hazards of unintentional injection of epinephrine from auto-injectors: a systematic review. Ann Allergy Asthma Immunol. 2009;102:282-287.
    • (2009) Ann Allergy Asthma Immunol , vol.102 , pp. 282-287
    • Simons, F.E.R.1    Lieberman, P.L.2    Read, E.J.3    Edwards, E.S.4
  • 7
    • 67651120040 scopus 로고    scopus 로고
    • Update on epinephrine (adrenaline) for pediatric emergencies
    • Walker DM. Update on epinephrine (adrenaline) for pediatric emergencies. Curr Opin Pediatr. 2009;21:313-319.
    • (2009) Curr Opin Pediatr , vol.21 , pp. 313-319
    • Walker, D.M.1
  • 8
    • 85022231239 scopus 로고    scopus 로고
    • What are the ‘ideal’ features of an adrenaline (epinephrine) auto-injector in the treatment of anaphylaxis?
    • Epub, Aug 17
    • Frew AJ. What are the ‘ideal’ features of an adrenaline (epinephrine) auto-injector in the treatment of anaphylaxis? Allergy. Epub 2010 Aug 17.
    • (2010) Allergy
    • Frew, A.J.1
  • 9
    • 85022190405 scopus 로고    scopus 로고
    • International Organization for Standardization (ISO). ISO 11608-1:2000. Pen-injectors for medical use. Part 1: pen-injectors-requirements and test methods. Available from, Accessed, Oct 1
    • International Organization for Standardization (ISO). ISO 11608-1:2000. Pen-injectors for medical use. Part 1: pen-injectors-requirements and test methods. Available from: http://www.iso.org/. Accessed 2010 Oct 1.
    • (2010)
  • 10
    • 33845222251 scopus 로고    scopus 로고
    • A pilot study to measure the compressive and tensile forces required to use retractable intramusclar safety syringes
    • Haiduven D, Applegarth S, DiSalvo H, Mangipudy S, Konopack J, Fisher J. A pilot study to measure the compressive and tensile forces required to use retractable intramusclar safety syringes. Am J Infect Control. 2006;34:661-668.
    • (2006) Am J Infect Control , vol.34 , pp. 661-668
    • Haiduven, D.1    Applegarth, S.2    Disalvo, H.3    Mangipudy, S.4    Konopack, J.5    Fisher, J.6
  • 12
    • 67349284688 scopus 로고    scopus 로고
    • Self-injectable epinephrine for allergic emergencies
    • Davis JE. Self-injectable epinephrine for allergic emergencies. J Emerg Med. 2009;37:57-62.
    • (2009) J Emerg Med , vol.37 , pp. 57-62
    • Davis, J.E.1
  • 13
    • 67649608053 scopus 로고    scopus 로고
    • Epinephrine auto-injectors: Is needle length adequate for delivery of epinephrine intramuscularly?
    • Stecher D, Bulloch B, Sales J, Schaefer C, Keahey L. Epinephrine auto-injectors: is needle length adequate for delivery of epinephrine intramuscularly? Pediatrics. 2009;124:65-70.
    • (2009) Pediatrics , vol.124 , pp. 65-70
    • Stecher, D.1    Bulloch, B.2    Sales, J.3    Schaefer, C.4    Keahey, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.