메뉴 건너뛰기




Volumn 87, Issue 2, 2016, Pages

A novel technique towards deployment of hydrostatic pressure based level sensor in nuclear fuel reprocessing facility

Author keywords

[No Author keywords available]

Indexed keywords

AIR; CAPACITIVE SENSORS; DATA ACQUISITION; HYDRAULICS; HYDROSTATIC PRESSURE; LEVEL MEASUREMENT; LIQUIDS; PETROLEUM RESERVOIR EVALUATION; PRESSURE SENSORS; UNCERTAINTY ANALYSIS;

EID: 85015243591     PISSN: 00346748     EISSN: 10897623     Source Type: Journal    
DOI: 10.1063/1.4941961     Document Type: Article
Times cited : (9)

References (30)
  • 3
    • 34250731203 scopus 로고    scopus 로고
    • Continous liquid level measurement using a linear electrode array
    • R. Casanella, O. Casas, and R. Pallas-Areny, "Continous liquid level measurement using a linear electrode array," Meas. Sci. Technol. 18, 1859-1866 (2007). 10.1088/0957-0233/18/7/010
    • (2007) Meas. Sci. Technol. , vol.18 , pp. 1859-1866
    • Casanella, R.1    Casas, O.2    Pallas-Areny, R.3
  • 4
    • 70349466794 scopus 로고    scopus 로고
    • A novel level measurement technique using three capacitive sensors for liquids
    • H. Canbolat, "A novel level measurement technique using three capacitive sensors for liquids," IEEE Trans. Instrum. Meas. 58 (10), 3762 (2009). 10.1109/tim.2009.2019715
    • (2009) IEEE Trans. Instrum. Meas. , vol.58 , Issue.10 , pp. 3762
    • Canbolat, H.1
  • 5
    • 33744544474 scopus 로고    scopus 로고
    • A low-cost noncontact capacitance-type level transducer for a conducting liquid
    • S. C. Bera, J. K. Ray, and S. Chattopadhyay, "A low-cost noncontact capacitance-type level transducer for a conducting liquid," IEEE Trans. Instrum. Meas. 55 (3), 778 (2006). 10.1109/tim.2006.873785
    • (2006) IEEE Trans. Instrum. Meas. , vol.55 , Issue.3 , pp. 778
    • Bera, S.C.1    Ray, J.K.2    Chattopadhyay, S.3
  • 6
    • 84894599177 scopus 로고    scopus 로고
    • Study of a modified capacitance-type level transducer for any type of liquid
    • S. C. Bera, H. Mandal, S. Saha, and A. Dutta, "Study of a modified capacitance-type level transducer for any type of liquid," IEEE Trans. Instrum. Meas. 63 (3), 641-649 (2014). 10.1109/TIM.2013.2282194
    • (2014) IEEE Trans. Instrum. Meas. , vol.63 , Issue.3 , pp. 641-649
    • Bera, S.C.1    Mandal, H.2    Saha, S.3    Dutta, A.4
  • 7
    • 34347237831 scopus 로고    scopus 로고
    • Liquid-level measurement system based on a remote grounded capacitive sensor
    • F. Reverter, X. Li, and G. C. M. Meijer, "Liquid-level measurement system based on a remote grounded capacitive sensor," Sens. Actuators, A 138, 1-8 (2007). 10.1016/j.sna.2007.04.027
    • (2007) Sens. Actuators, A , vol.138 , pp. 1-8
    • Reverter, F.1    Li, X.2    Meijer, G.C.M.3
  • 8
    • 34250174151 scopus 로고    scopus 로고
    • A wireless fluid-level measurement technique
    • S. E. Woodard and B. D. Taylor, "A wireless fluid-level measurement technique," Sens. Actuators, A 137, 268-278 (2007). 10.1016/j.sna.2007.03.031
    • (2007) Sens. Actuators, A , vol.137 , pp. 268-278
    • Woodard, S.E.1    Taylor, B.D.2
  • 9
    • 0942278999 scopus 로고    scopus 로고
    • A novel liquid level detection method and its implementation
    • E. Musayev and S. E. Karlik, "A novel liquid level detection method and its implementation," Sens. Actuators, A 109, 21-24 (2003). 10.1016/S0924-4247(03)00347-9
    • (2003) Sens. Actuators, A , vol.109 , pp. 21-24
    • Musayev, E.1    Karlik, S.E.2
  • 10
    • 84873201025 scopus 로고    scopus 로고
    • Truly nonintrusive liquid-level-sensing method based on lateral displacement effect of light rays
    • H. K. Singh, N. C. Meitei, S. T. Sarkar, D. Tiwari, and T. Bezboruah, "Truly nonintrusive liquid-level-sensing method based on lateral displacement effect of light rays," IEEE Sens. J. 13 (2), 801-806 (2013). 10.1109/JSEN.2012.2227594
    • (2013) IEEE Sens. J. , vol.13 , Issue.2 , pp. 801-806
    • Singh, H.K.1    Meitei, N.C.2    Sarkar, S.T.3    Tiwari, D.4    Bezboruah, T.5
  • 11
    • 78649306771 scopus 로고    scopus 로고
    • A new non-intrusive optical technique to measure transparent liquid level and volume
    • H. K. Singh, S. K. Chakroborty, H. Talukdar, N. M. Singh, and T. Bezboruah, "A new non-intrusive optical technique to measure transparent liquid level and volume," IEEE Sens. J. 11 (2), 391-398 (2011). 10.1109/JSEN.2010.2068543
    • (2011) IEEE Sens. J. , vol.11 , Issue.2 , pp. 391-398
    • Singh, H.K.1    Chakroborty, S.K.2    Talukdar, H.3    Singh, N.M.4    Bezboruah, T.5
  • 12
    • 63649101574 scopus 로고    scopus 로고
    • Asymmetric Fabry-Pérot fiber-optic pressure sensor for liquid-level measurement
    • T. Lu, Z. Li, D. Xia, K. He, and G. Zhang, "Asymmetric Fabry-Pérot fiber-optic pressure sensor for liquid-level measurement," Rev. Sci. Instrum. 80, 033104 (2009). 10.1063/1.3093808
    • (2009) Rev. Sci. Instrum. , vol.80
    • Lu, T.1    Li, Z.2    Xia, D.3    He, K.4    Zhang, G.5
  • 13
    • 84875425822 scopus 로고    scopus 로고
    • The novel measurement method of liquid level and density in airtight container
    • Z. Niu, Y. Zhao, B. Tian, and F. Guo, "The novel measurement method of liquid level and density in airtight container," Rev. Sci. Instrum. 83, 125108 (2012). 10.1063/1.4770332
    • (2012) Rev. Sci. Instrum. , vol.83
    • Niu, Z.1    Zhao, Y.2    Tian, B.3    Guo, F.4
  • 14
    • 0027737635 scopus 로고
    • Flexural wave sidewall sensor for noninvasive measurement of discrete liquid levels in large storage tanks
    • Y. Liu and L. C. Lynnworth, "Flexural wave sidewall sensor for noninvasive measurement of discrete liquid levels in large storage tanks," Proc.-IEEE Ultrason. Symp. 1, 385-390 (1993). 10.1109/ultsym.1993.339464
    • (1993) Proc. - IEEE Ultrason. Symp. , vol.1 , pp. 385-390
    • Liu, Y.1    Lynnworth, L.C.2
  • 16
    • 0035731011 scopus 로고    scopus 로고
    • Ultrasonic sensors for process Industry
    • P. Hauptmann, N. Hoppe, and A. Puettmer, "Ultrasonic sensors for process Industry," IEEE Ultrason. Symp. 1, 369-378 (2001). 10.1109/ultsym.2001.991644
    • (2001) IEEE Ultrason. Symp. , vol.1 , pp. 369-378
    • Hauptmann, P.1    Hoppe, N.2    Puettmer, A.3
  • 17
    • 4644362874 scopus 로고    scopus 로고
    • A new ultrasonic-based device for accurate measurement of oil, emulsion, and water levels in oil tanks
    • M. Meribout, M. Habli, A. Al-Naamani, and K. Al-Busaidi, "A new ultrasonic-based device for accurate measurement of oil, emulsion, and water levels in oil tanks," IEEE Instrum. Meas. Technol. Conf. 3, 1942-1947 (2004). 10.1109/imtc.2004.1351467
    • (2004) IEEE Instrum. Meas. Technol. Conf. , vol.3 , pp. 1942-1947
    • Meribout, M.1    Habli, M.2    Al-Naamani, A.3    Al-Busaidi, K.4
  • 18
    • 84923829338 scopus 로고    scopus 로고
    • Level monitoring system with pulating sensor-application to online level monitoring of dashpots in fast breeder reactor
    • N. Malathi, P. Sahoo, R. Ananthanarayanan, and N. Murali, "Level monitoring system with pulating sensor-application to online level monitoring of dashpots in fast breeder reactor," Rev. Sci. Instrum. 86, 025103 (2015). 10.1063/1.4906817
    • (2015) Rev. Sci. Instrum. , vol.86
    • Malathi, N.1    Sahoo, P.2    Ananthanarayanan, R.3    Murali, N.4
  • 19
    • 84055187700 scopus 로고    scopus 로고
    • Investigation of free level fluctuations in a simulated model of a sodium cooled fast breeder reactor using pulsating conductance monitoring device
    • P. K. Aggarwal, G. K. Pandey, N. Malathi, A. D. Arun, R. Ananthanarayanan, I. Banerjee, P. Sahoo, G. Padmakumar, and N. Murali, "Investigation of free level fluctuations in a simulated model of a sodium cooled fast breeder reactor using pulsating conductance monitoring device," Ann. Nucl. Energy 41, 87-96 (2012). 10.1016/j.anucene.2011.11.020
    • (2012) Ann. Nucl. Energy , vol.41 , pp. 87-96
    • Aggarwal, P.K.1    Pandey, G.K.2    Malathi, N.3    Arun, A.D.4    Ananthanarayanan, R.5    Banerjee, I.6    Sahoo, P.7    Padmakumar, G.8    Murali, N.9
  • 23
    • 80054739235 scopus 로고    scopus 로고
    • High-performance differential pressure monitoring devices using pulsating sensors for a sodium-cooled fast breeder reactor
    • K. Praveen, M. P. Rajiniganth, A. D. Arun, R. Ananthanarayanan, N. Malathi, P. Sahoo, and N. Murali, "High-performance differential pressure monitoring devices using pulsating sensors for a sodium-cooled fast breeder reactor," Nucl. Technol. 176, 127-137 (2011).
    • (2011) Nucl. Technol. , vol.176 , pp. 127-137
    • Praveen, K.1    Rajiniganth, M.P.2    Arun, A.D.3    Ananthanarayanan, R.4    Malathi, N.5    Sahoo, P.6    Murali, N.7
  • 25
    • 21744451536 scopus 로고    scopus 로고
    • Accuracy and resolution of direct resistive sensor-to microcontroller interfaces
    • F. Reverter, J. Jordana, M. Gasulla, and R. Pallàs-Areny, "Accuracy and resolution of direct resistive sensor-to microcontroller interfaces," Sens. Actuators, A 121, 78-87 (2005). 10.1016/j.sna.2005.01.010
    • (2005) Sens. Actuators, A , vol.121 , pp. 78-87
    • Reverter, F.1    Jordana, J.2    Gasulla, M.3    Pallàs-Areny, R.4
  • 26
    • 84866875426 scopus 로고    scopus 로고
    • A microcontroller-based lock-in amplifier for sub-milliohm resistance measurements
    • L. E. Bengtsson, "A microcontroller-based lock-in amplifier for sub-milliohm resistance measurements," Rev. Sci. Instrum. 83, 075103 (2012). 10.1063/1.4731683
    • (2012) Rev. Sci. Instrum. , vol.83
    • Bengtsson, L.E.1
  • 28
    • 84941670801 scopus 로고    scopus 로고
    • An improved capacitance-to-digital converter for leaky capacitive sensors
    • P. Vooka and B. George, "An improved capacitance-to-digital converter for leaky capacitive sensors," IEEE Sens. J. 15 (11), 6238-6247 (2015). 10.1109/jsen.2015.2454531
    • (2015) IEEE Sens. J. , vol.15 , Issue.11 , pp. 6238-6247
    • Vooka, P.1    George, B.2
  • 29
    • 41349102540 scopus 로고    scopus 로고
    • Direct interface circuit for capacitive humidity sensors
    • F. Reverter and Ò. Casas, "Direct interface circuit for capacitive humidity sensors," Sens. Actuators, A 143, 315-322 (2008). 10.1016/j.sna.2007.11.018
    • (2008) Sens. Actuators, A , vol.143 , pp. 315-322
    • Reverter, F.1    Casas, Ò.2
  • 30
    • 0036826018 scopus 로고    scopus 로고
    • An accurate interface for capacitive sensors
    • X. Li and G. C. M. Meijer, "An accurate interface for capacitive sensors," IEEE Trans. Instrum. Meas. 51 (5), 935-939 (2002). 10.1109/TIM.2002.807793
    • (2002) IEEE Trans. Instrum. Meas. , vol.51 , Issue.5 , pp. 935-939
    • Li, X.1    Meijer, G.C.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.