메뉴 건너뛰기




Volumn 19, Issue 5, 2017, Pages 713-720

Outpatient 60-hour day-and-night glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or sensor-augmented pump therapy in adults with type 1 diabetes: An open-label, randomised, crossover, controlled trial

Author keywords

artificial pancreas, closed loop insulin delivery, glucagon; hypoglycaemia; insulin therapy; randomised trial; type 1 diabetes

Indexed keywords

HEMOGLOBIN A1C; INSULIN; GLUCAGON; GLUCOSE BLOOD LEVEL; GLYCOSYLATED HEMOGLOBIN; HEMOGLOBIN A1C PROTEIN, HUMAN;

EID: 85014656780     PISSN: 14628902     EISSN: 14631326     Source Type: Journal    
DOI: 10.1111/dom.12880     Document Type: Article
Times cited : (55)

References (23)
  • 1
    • 84942755473 scopus 로고    scopus 로고
    • Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D exchange clinic registry
    • Miller KM, Foster NC, Beck RW, et al.; Network TDEC. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D exchange clinic registry. Diabetes Care. 2015;38:971-978.
    • (2015) Diabetes Care , vol.38 , pp. 971-978
    • Miller, K.M.1    Foster, N.C.2    Beck, R.W.3
  • 2
    • 0036020278 scopus 로고    scopus 로고
    • Hypoglycaemia: the limiting factor in the glycaemic management of Type I and Type II diabetes
    • Cryer PE. Hypoglycaemia: the limiting factor in the glycaemic management of Type I and Type II diabetes. Diabetologia. 2002;45:937-948.
    • (2002) Diabetologia , vol.45 , pp. 937-948
    • Cryer, P.E.1
  • 3
    • 77952687348 scopus 로고    scopus 로고
    • Frequency of biochemical hypoglycaemia in adults with Type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring
    • Choudhary P, Geddes J, Freeman JV, Emery CJ, Heller SR, Frier BM. Frequency of biochemical hypoglycaemia in adults with Type 1 diabetes with and without impaired awareness of hypoglycaemia: no identifiable differences using continuous glucose monitoring. Diabet Med. 2010;27:666-672.
    • (2010) Diabet Med , vol.27 , pp. 666-672
    • Choudhary, P.1    Geddes, J.2    Freeman, J.V.3    Emery, C.J.4    Heller, S.R.5    Frier, B.M.6
  • 4
    • 84962077682 scopus 로고    scopus 로고
    • Severe hypoglycemia requiring medical intervention in a large cohort of adults with diabetes receiving care in U.S. integrated health care delivery systems: 2005–2011
    • Pathak RD, Schroeder EB, Seaquist ER, et al.; SUPREME-DM Study Group. Severe hypoglycemia requiring medical intervention in a large cohort of adults with diabetes receiving care in U.S. integrated health care delivery systems: 2005–2011. Diabetes Care. 2016;39:363-370.
    • (2016) Diabetes Care , vol.39 , pp. 363-370
    • Pathak, R.D.1    Schroeder, E.B.2    Seaquist, E.R.3
  • 5
    • 48649097595 scopus 로고    scopus 로고
    • Acute complications and drug misuse are important causes of death for children and young adults with type 1 diabetes: results from the Yorkshire Register of diabetes in children and young adults
    • Feltbower RG, Bodansky HJ, Patterson CC, et al. Acute complications and drug misuse are important causes of death for children and young adults with type 1 diabetes: results from the Yorkshire Register of diabetes in children and young adults. Diabetes Care. 2008;31:922-926.
    • (2008) Diabetes Care , vol.31 , pp. 922-926
    • Feltbower, R.G.1    Bodansky, H.J.2    Patterson, C.C.3
  • 6
    • 79959616082 scopus 로고    scopus 로고
    • Closed-loop insulin delivery: from bench to clinical practice
    • Hovorka R. Closed-loop insulin delivery: from bench to clinical practice. Nat Rev Endocrinol. 2011;7:385-395.
    • (2011) Nat Rev Endocrinol , vol.7 , pp. 385-395
    • Hovorka, R.1
  • 7
    • 84875188726 scopus 로고    scopus 로고
    • Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial
    • Haidar A, Legault L, Dallaire M, et al. Glucose-responsive insulin and glucagon delivery (dual-hormone artificial pancreas) in adults with type 1 diabetes: a randomized crossover controlled trial. CMAJ. 2013;185:297-305.
    • (2013) CMAJ , vol.185 , pp. 297-305
    • Haidar, A.1    Legault, L.2    Dallaire, M.3
  • 9
    • 77956071742 scopus 로고    scopus 로고
    • Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes
    • Castle JR, Engle JM, El Youssef J, et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care. 2010;33:1282-1287.
    • (2010) Diabetes Care , vol.33 , pp. 1282-1287
    • Castle, J.R.1    Engle, J.M.2    El Youssef, J.3
  • 10
    • 84910135134 scopus 로고    scopus 로고
    • MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: Randomized crossover trial
    • Nimri R, Muller I, Atlas E, et al. MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: Randomized crossover trial. Diabetes Care. 2014;37:3025–3032.
    • (2004) Diabetes Care , vol.37 , pp. 3025-3032
    • Nimri, R.1    Muller, I.2    Atlas, E.3
  • 11
    • 84908316913 scopus 로고    scopus 로고
    • Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study
    • Thabit H, Lubina-Solomon A, Stadler M, et al. Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study. Lancet Diabetes Endocrinol. 2014;2:701-709.
    • (2014) Lancet Diabetes Endocrinol , vol.2 , pp. 701-709
    • Thabit, H.1    Lubina-Solomon, A.2    Stadler, M.3
  • 12
    • 84948082694 scopus 로고    scopus 로고
    • 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial
    • Kropff J, Del Favero S, Place J, et al.; AP@home Consortium. 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial. Lancet Diabetes Endocrinol. 2015;3(12):939–947.
    • (2015) Lancet Diabetes Endocrinol , vol.3 , Issue.12 , pp. 939-947
    • Kropff, J.1    Del Favero, S.2    Place, J.3
  • 13
    • 84926287781 scopus 로고    scopus 로고
    • Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial
    • Haidar A, Legault L, Messier V, Mitre TM, Leroux C, Rabasa-Lhoret R. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Lancet Diabetes Endocrinol. 2015;3:17-26.
    • (2015) Lancet Diabetes Endocrinol , vol.3 , pp. 17-26
    • Haidar, A.1    Legault, L.2    Messier, V.3    Mitre, T.M.4    Leroux, C.5    Rabasa-Lhoret, R.6
  • 14
    • 84946427627 scopus 로고    scopus 로고
    • Home use of an artificial beta cell in Type 1 diabetes
    • Thabit H, Tauschmann M, Allen JM, et al.; for the APCam Consortium and AP@home Consortium. Home use of an artificial beta cell in Type 1 diabetes. N Engl J Med. 2015;373(22):2129–2140.
    • (2015) N Engl J Med , vol.373 , Issue.22 , pp. 2129-2140
    • Thabit, H.1    Tauschmann, M.2    Allen, J.M.3
  • 15
    • 84903547471 scopus 로고    scopus 로고
    • Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study
    • Leelarathna L, Dellweg S, Mader JK, et al.; AP@home Consortium. Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study. Diabetes Care. 2014;37:1931-1937.
    • (2014) Diabetes Care , vol.37 , pp. 1931-1937
    • Leelarathna, L.1    Dellweg, S.2    Mader, J.K.3
  • 16
    • 84904574791 scopus 로고    scopus 로고
    • Outpatient glycemic control with a bionic pancreas in type 1 diabetes
    • Russell SJ, El-Khatib FH, Sinha M, et al. Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med. 2014;371:313-325.
    • (2014) N Engl J Med , vol.371 , pp. 313-325
    • Russell, S.J.1    El-Khatib, F.H.2    Sinha, M.3
  • 17
    • 84964319821 scopus 로고    scopus 로고
    • Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home
    • Blauw H, van Bon AC, Koops R, DeVries JH, on behalf of the PCDIAB consortium. Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home. Diabetes Obes Metab. 2016;18(7):671–677.
    • (2016) Diabetes Obes Metab , vol.18 , Issue.7 , pp. 671-677
    • Blauw, H.1    van Bon, A.C.2    Koops, R.3    DeVries, J.H.4
  • 18
    • 84992238301 scopus 로고    scopus 로고
    • Multinational home use of closed-loop control is safe and effective
    • Anderson SM, Raghinaru D, Pinsker JE, et al.; Control to Range Study Group. Multinational home use of closed-loop control is safe and effective. Diabetes Care. 2016;39:1143-1150.
    • (2016) Diabetes Care , vol.39 , pp. 1143-1150
    • Anderson, S.M.1    Raghinaru, D.2    Pinsker, J.E.3
  • 19
    • 84992281723 scopus 로고    scopus 로고
    • Day-and-night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: results of a single-arm 1-month experience compared with a previously reported feasibility study of evening and night at home
    • Renard E, Farret A, Kropff J, et al.; AP@home Consortium. Day-and-night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: results of a single-arm 1-month experience compared with a previously reported feasibility study of evening and night at home. Diabetes Care. 2016;39:1151-1160.
    • (2016) Diabetes Care , vol.39 , pp. 1151-1160
    • Renard, E.1    Farret, A.2    Kropff, J.3
  • 20
    • 84904574791 scopus 로고    scopus 로고
    • Outpatient glycemic control with a bionic pancreas in type 1 diabetes
    • Russell SJ, El-Khatib FH, Sinha M, et al. Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med. 2014;371:313-325.
    • (2014) N Engl J Med , vol.371 , pp. 313-325
    • Russell, S.J.1    El-Khatib, F.H.2    Sinha, M.3
  • 21
    • 84899117172 scopus 로고    scopus 로고
    • Overnight closed-loop insulin delivery in young people with type 1 diabetes: a free-living, randomized clinical trial
    • Hovorka R, Elleri D, Thabit H, et al. Overnight closed-loop insulin delivery in young people with type 1 diabetes: a free-living, randomized clinical trial. Diabetes Care. 2014;37:1204-1211.
    • (2014) Diabetes Care , vol.37 , pp. 1204-1211
    • Hovorka, R.1    Elleri, D.2    Thabit, H.3
  • 22
    • 84905038018 scopus 로고    scopus 로고
    • Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes cAMP
    • Ly TT, Breton MD, Keith-Hynes P, et al. Overnight glucose control with an automated, unified safety system in children and adolescents with type 1 diabetes at diabetes cAMP. Diabetes Care. 2014;37:2310-2316.
    • (2014) Diabetes Care , vol.37 , pp. 2310-2316
    • Ly, T.T.1    Breton, M.D.2    Keith-Hynes, P.3
  • 23
    • 48149095259 scopus 로고    scopus 로고
    • Translating the A1C assay into estimated average glucose values
    • Nathan DM, Kuenen J, Borg R, et al.; A1c-Derived Average Glucose Study Group. Translating the A1C assay into estimated average glucose values. Diabetes Care. 2008;31:1473-1478.
    • (2008) Diabetes Care , vol.31 , pp. 1473-1478
    • Nathan, D.M.1    Kuenen, J.2    Borg, R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.