메뉴 건너뛰기




Volumn 18, Issue 7, 2016, Pages 671-677

Performance and safety of an integrated bihormonal artificial pancreas for fully automated glucose control at home

Author keywords

clinical trial; glucagon; glycaemic control; insulin therapy; type 1 diabetes

Indexed keywords

GLUCAGON; GLUCOSE; INSULIN; ANTIDIABETIC AGENT; GLUCOSE BLOOD LEVEL; INSULIN DERIVATIVE;

EID: 84964319821     PISSN: 14628902     EISSN: 14631326     Source Type: Journal    
DOI: 10.1111/dom.12663     Document Type: Article
Times cited : (90)

References (18)
  • 1
    • 84910135134 scopus 로고    scopus 로고
    • MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial
    • Nimri R, Muller I, Atlas E et al. MD-logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial. Diabetes Care 2014; 37: 3025–3032.
    • (2014) Diabetes Care , vol.37 , pp. 3025-3032
    • Nimri, R.1    Muller, I.2    Atlas, E.3
  • 2
    • 84948082694 scopus 로고    scopus 로고
    • 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial
    • Kropff J, Del Favero S, Place J et al. 2 month evening and night closed-loop glucose control in patients with type 1 diabetes under free-living conditions: a randomised crossover trial. Lancet Diabetes Endocrinol 2015; 3: 939–947.
    • (2015) Lancet Diabetes Endocrinol , vol.3 , pp. 939-947
    • Kropff, J.1    Del Favero, S.2    Place, J.3
  • 3
    • 84946427627 scopus 로고    scopus 로고
    • Home use of an artificial beta cell in type 1 diabetes
    • Thabit H, Tauschmann M, Allen JM et al. Home use of an artificial beta cell in type 1 diabetes. N Engl J Med 2015; 373: 2129–2140.
    • (2015) N Engl J Med , vol.373 , pp. 2129-2140
    • Thabit, H.1    Tauschmann, M.2    Allen, J.M.3
  • 4
    • 84926287781 scopus 로고    scopus 로고
    • Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial
    • Haidar A, Legault L, Messier V, Mitre TM, Leroux C, Rabasa-Lhoret R. Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Lancet Diabetes Endocrinol 2015; 3: 17–26.
    • (2015) Lancet Diabetes Endocrinol , vol.3 , pp. 17-26
    • Haidar, A.1    Legault, L.2    Messier, V.3    Mitre, T.M.4    Leroux, C.5    Rabasa-Lhoret, R.6
  • 5
    • 84907469976 scopus 로고    scopus 로고
    • Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies
    • Jacobs PG, El Youssef J, Castle J et al. Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies. IEEE Trans Biomed Eng 2014; 61: 2569–2581.
    • (2014) IEEE Trans Biomed Eng , vol.61 , pp. 2569-2581
    • Jacobs, P.G.1    El Youssef, J.2    Castle, J.3
  • 6
    • 84904574791 scopus 로고    scopus 로고
    • Outpatient glycemic control with a bionic pancreas in type 1 diabetes
    • Russell SJ, El-Khatib FH, Sinha M et al. Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med 2014; 371: 313–325.
    • (2014) N Engl J Med , vol.371 , pp. 313-325
    • Russell, S.J.1    El-Khatib, F.H.2    Sinha, M.3
  • 7
    • 84959557141 scopus 로고    scopus 로고
    • Day and night glycaemic control with a bionic pancreas versus conventional insulin pump therapy in preadolescent children with type 1 diabetes: a randomised crossover trial
    • Russell SJ, Hillard MA, Balliro C et al. Day and night glycaemic control with a bionic pancreas versus conventional insulin pump therapy in preadolescent children with type 1 diabetes: a randomised crossover trial. Lancet Diabetes Endocrinol 2016; 4: 233–243.
    • (2016) Lancet Diabetes Endocrinol , vol.4 , pp. 233-243
    • Russell, S.J.1    Hillard, M.A.2    Balliro, C.3
  • 8
    • 84896888057 scopus 로고    scopus 로고
    • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours
    • van Bon AC, Luijf YM, Koebrugge R, Koops R, Hoekstra JB, Devries JH. Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours. Diabetes Technol Ther 2014; 16: 131–136.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 131-136
    • van Bon, A.C.1    Luijf, Y.M.2    Koebrugge, R.3    Koops, R.4    Hoekstra, J.B.5    Devries, J.H.6
  • 9
    • 84930599404 scopus 로고    scopus 로고
    • Efficacy of dual-hormone artificial pancreas to alleviate the carbohydrate-counting burden of type 1 diabetes: a randomized crossover trial
    • Gingras V, Rabasa-Lhoret R, Messier V, Ladouceur M, Legault L, Haidar A. Efficacy of dual-hormone artificial pancreas to alleviate the carbohydrate-counting burden of type 1 diabetes: a randomized crossover trial. Diabetes Metab 2016; 42: 47–54.
    • (2016) Diabetes Metab , vol.42 , pp. 47-54
    • Gingras, V.1    Rabasa-Lhoret, R.2    Messier, V.3    Ladouceur, M.4    Legault, L.5    Haidar, A.6
  • 10
    • 84908316913 scopus 로고    scopus 로고
    • Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study
    • Thabit H, Lubina-Solomon A, Stadler M et al. Home use of closed-loop insulin delivery for overnight glucose control in adults with type 1 diabetes: a 4-week, multicentre, randomised crossover study. Lancet Diabetes Endocrinol 2014; 2: 701–709.
    • (2014) Lancet Diabetes Endocrinol , vol.2 , pp. 701-709
    • Thabit, H.1    Lubina-Solomon, A.2    Stadler, M.3
  • 11
    • 84948440168 scopus 로고    scopus 로고
    • Day and night closed-loop control using the integrated medtronic hybrid closed-loop system in type 1 diabetes at diabetes camp
    • Ly TT, Roy A, Grosman B et al. Day and night closed-loop control using the integrated medtronic hybrid closed-loop system in type 1 diabetes at diabetes camp. Diabetes Care 2015; 38: 1205–1211.
    • (2015) Diabetes Care , vol.38 , pp. 1205-1211
    • Ly, T.T.1    Roy, A.2    Grosman, B.3
  • 12
    • 0028292096 scopus 로고
    • Frequency of severe hypoglycemia in patients with type I diabetes with impaired awareness of hypoglycemia
    • Gold AE, MacLeod KM, Frier BM. Frequency of severe hypoglycemia in patients with type I diabetes with impaired awareness of hypoglycemia. Diabetes Care 1994; 17: 697–703.
    • (1994) Diabetes Care , vol.17 , pp. 697-703
    • Gold, A.E.1    MacLeod, K.M.2    Frier, B.M.3
  • 13
    • 0028958816 scopus 로고
    • Reduced awareness of hypoglycemia in adults with IDDM. A prospective study of hypoglycemic frequency and associated symptoms
    • Clarke WL, Cox DJ, Gonder-Frederick LA, Julian D, Schlundt D, Polonsky W. Reduced awareness of hypoglycemia in adults with IDDM. A prospective study of hypoglycemic frequency and associated symptoms. Diabetes Care 1995; 18: 517–522.
    • (1995) Diabetes Care , vol.18 , pp. 517-522
    • Clarke, W.L.1    Cox, D.J.2    Gonder-Frederick, L.A.3    Julian, D.4    Schlundt, D.5    Polonsky, W.6
  • 14
    • 84955191962 scopus 로고    scopus 로고
    • Pharmacokinetics and pharmacodynamics of various glucagon dosages at different blood glucose levels
    • Blauw H, Wendl I, DeVries JH, Heise T, Jax T, consortium P. Pharmacokinetics and pharmacodynamics of various glucagon dosages at different blood glucose levels. Diabetes Obes Metab 2016; 18: 34–39.
    • (2016) Diabetes Obes Metab , vol.18 , pp. 34-39
    • Blauw, H.1    Wendl, I.2    DeVries, J.H.3    Heise, T.4    Jax, T.5    consortium, P.6
  • 15
    • 70349240850 scopus 로고    scopus 로고
    • Statistical tools to analyze continuous glucose monitor data
    • Clarke W, Kovatchev B. Statistical tools to analyze continuous glucose monitor data. Diabetes Technol Ther 2009; 11: S45–S54.
    • (2009) Diabetes Technol Ther , vol.11 , pp. S45-S54
    • Clarke, W.1    Kovatchev, B.2
  • 16
    • 23644448095 scopus 로고    scopus 로고
    • The dawn phenomenon revisited: implications for diabetes therapy
    • Carroll MF, Schade DS. The dawn phenomenon revisited: implications for diabetes therapy. Endocr Pract 2005; 11: 55–64.
    • (2005) Endocr Pract , vol.11 , pp. 55-64
    • Carroll, M.F.1    Schade, D.S.2
  • 17
    • 84870703307 scopus 로고    scopus 로고
    • Stable liquid glucagon formulations for rescue treatment and bi-hormonal closed-loop pancreas
    • Jackson MA, Caputo N, Castle JR, David LL, Roberts CT Jr, Ward WK. Stable liquid glucagon formulations for rescue treatment and bi-hormonal closed-loop pancreas. Curr Diab Rep 2012; 12: 705–710.
    • (2012) Curr Diab Rep , vol.12 , pp. 705-710
    • Jackson, M.A.1    Caputo, N.2    Castle, J.R.3    David, L.L.4    Roberts, C.T.5    Ward, W.K.6
  • 18
    • 84955316495 scopus 로고    scopus 로고
    • Reimbursement for continuous glucose monitoring
    • Heinemann L, DeVries JH. Reimbursement for continuous glucose monitoring. Diabetes Technol Ther 2016; 18: S248–S252.
    • (2016) Diabetes Technol Ther , vol.18 , pp. S248-S252
    • Heinemann, L.1    DeVries, J.H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.