메뉴 건너뛰기




Volumn 282, Issue 3, 2017, Pages 850-856

Diffusion tractography of the entire left ventricle by using free-breathing accelerated simultaneous multisection imaging

Author keywords

[No Author keywords available]

Indexed keywords

BREATH HOLDING; CARDIAC IMAGING; CLINICAL ARTICLE; CONTROLLED STUDY; DIFFUSION TENSOR IMAGING; FRACTIONAL ANISOTROPY; HEART LEFT VENTRICLE; HEART RIGHT VENTRICLE OVERLOAD; HUMAN; LUNG FIBROSIS; NUCLEAR MAGNETIC RESONANCE SCANNER; PULMONARY HYPERTENSION; REVIEW; SIMULTANEOUS MULTISECTION IMAGING; BREATHING; COMPUTER ASSISTED DIAGNOSIS; DIAGNOSTIC IMAGING; FEASIBILITY STUDY; HEART VENTRICLE; IMAGE PROCESSING; NUCLEAR MAGNETIC RESONANCE IMAGING; PROCEDURES; THREE DIMENSIONAL IMAGING;

EID: 85013392447     PISSN: 00338419     EISSN: 15271315     Source Type: Journal    
DOI: 10.1148/radiol.2016152613     Document Type: Review
Times cited : (34)

References (25)
  • 2
    • 33846834120 scopus 로고    scopus 로고
    • Diffusion imaging of the in vivo heart using spin echoes- considerations on bulk, motion sensitivity
    • Gamper U, Boesiger P, Kozerke S. Diffusion imaging of the in vivo heart using spin echoes- considerations on bulk motion sensitivity. Magn Reson Med 2007;57(2):331-337.
    • (2007) Magn Reson Med , vol.57 , Issue.2 , pp. 331-337
    • Gamper, U.1    Boesiger, P.2    Kozerke, S.3
  • 3
    • 0032866251 scopus 로고    scopus 로고
    • Cardiac diffusion tensor MRI in vivo without strain correction
    • Tseng WY, Reese TG, Weisskoff RM, Wedeen VJ. Cardiac diffusion tensor MRI in vivo without strain correction. Magn Reson Med 1999;42(2):393-403.
    • (1999) Magn Reson Med , vol.42 , Issue.2 , pp. 393-403
    • Tseng, W.Y.1    Reese, T.G.2    Weisskoff, R.M.3    Wedeen, V.J.4
  • 4
    • 84881190089 scopus 로고    scopus 로고
    • In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches
    • Nielles-Vallespin S, Mekkaoui C, Gatehouse P, et al. In vivo diffusion tensor MRI of the human heart: Reproducibility of breath-hold and navigator-based approaches. Magn Reson Med 2013;70(2):454-465.
    • (2013) Magn Reson Med , vol.70 , Issue.2 , pp. 454-465
    • Nielles-Vallespin, S.1    Mekkaoui, C.2    Gatehouse, P.3
  • 5
    • 68949111022 scopus 로고    scopus 로고
    • Sequential changes of myocardial microstructure in patients postmyocardial infarction by diffusion-Tensor cardiac MR: Correlation with left ventricular structure and function
    • 6, 40
    • Wu MT, Su MY, Huang YL, et al. Sequential changes of myocardial microstructure in patients postmyocardial infarction by diffusion-Tensor cardiac MR: correlation with left ventricular structure and function. Circ Cardiovasc Imaging 2009;2(1):32-40, 6, 40.
    • (2009) Circ Cardiovasc, Imaging , vol.2 , Issue.1 , pp. 32-40
    • Wu, M.T.1    Su, M.Y.2    Huang, Y.L.3
  • 6
    • 79251636579 scopus 로고    scopus 로고
    • Whole-heart modeling: Applications to cardiac electrophysiology and electromechanics
    • Trayanova NA. Whole-heart modeling: Applications to cardiac electrophysiology and electromechanics. Circ Res 2011;108(1): 113-128.
    • (2011) Circ Res , vol.108 , Issue.1 , pp. 113-128
    • Trayanova, N.A.1
  • 7
    • 84908094522 scopus 로고    scopus 로고
    • Posterior papillary muscle anchoring affects remote myofiber stress and pump function: Finite element analysis
    • Pantoja JL, Ge L, Zhang Z, et al. Posterior papillary muscle anchoring affects remote myofiber stress and pump function: finite element analysis. Ann Thorac Surg 2014;98(4): 1355-1362.
    • (2014) Ann Thorac Surg , vol.98 , Issue.4 , pp. 1355-1362
    • Pantoja, J.L.1    Ge, L.2    Zhang, Z.3
  • 8
    • 84867317122 scopus 로고    scopus 로고
    • Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation
    • Mekkaoui C, Huang S, Chen HH, et al. Fiber architecture in remodeled myocardium revealed with a quantitative diffusion CMR tractography framework and histological validation. J Cardiovasc Magn Reson 2012;14:70.
    • (2012) J Cardiovasc Magn Reson , vol.14 , pp. 70
    • Mekkaoui, C.1    Huang, S.2    Chen, H.H.3
  • 9
    • 84859705233 scopus 로고    scopus 로고
    • Blippedcontrolled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty
    • Setsompop K, Gagoski BA, Polimeni JR, Witzel T, Wedeen VJ, Wald LL. Blippedcontrolled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced g-factor penalty. Magn Reson Med 2012;67(5):1210-1224.
    • (2012) Magn Reson Med , vol.67 , Issue.5 , pp. 1210-1224
    • Setsompop, K.1    Gagoski, B.A.2    Polimeni, J.R.3    Witzel, T.4    Wedeen, V.J.5    Wald, L.L.6
  • 10
    • 84865413556 scopus 로고    scopus 로고
    • Improving diffusion MRI using simultaneous multi-slice echo planar, imaging
    • Setsompop K, Cohen-Adad J, Gagoski BA, et al. Improving diffusion MRI using simultaneous multi-slice echo planar imaging. Neuroimage 2012;63(1):569-580.
    • (2012) Neuroimage , vol.63 , Issue.1 , pp. 569-580
    • Setsompop, K.1    Cohen-Adad, J.2    Gagoski, B.A.3
  • 12
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partiallyparallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partiallyparallel acquisitions (GRAPPA). Magn Reson Med 2002;47(6):1202-1210.
    • (2002) Magn Reson Med , vol.47 , Issue.6 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 13
    • 84907000330 scopus 로고    scopus 로고
    • Dual-phase cardiac diffusion tensor imaging with strain correction
    • Stoeck CT, Kalinowska A, von Deuster C, et al. Dual-phase cardiac diffusion tensor imaging with strain correction. PLoS One 2014;9(9):e107159.
    • (2014) PLoS One , vol.9 , Issue.9 , pp. e107159
    • Stoeck, C.T.1    Kalinowska, A.2    Von Deuster, C.3
  • 15
    • 84937679226 scopus 로고    scopus 로고
    • Optimal diffusion weighting for in vivo cardiac diffusion tensor, imaging
    • Scott AD, Ferreira PF, Nielles-Vallespin S, et al. Optimal diffusion weighting for in vivo cardiac diffusion tensor imaging. Magn Reson Med 2015;74(2):420-430.
    • (2015) Magn Reson Med , vol.74 , Issue.2 , pp. 420-430
    • Scott, A.D.1    Ferreira, P.F.2    Nielles-Vallespin, S.3
  • 16
    • 49749087104 scopus 로고    scopus 로고
    • Information entropy measure for evaluation of image quality
    • Tsai DY, Lee Y, Matsuyama E. Information entropy measure for evaluation of image quality. J Digit Imaging 2008;21(3):338- 347.
    • (2008) J Digit Imaging , vol.21 , Issue.3 , pp. 338-347
    • Tsai, D.Y.1    Lee, Y.2    Matsuyama, E.3
  • 17
    • 0029403019 scopus 로고
    • Inferring microstructural features and the physiological state of tissues from diffusion-weighted images
    • Basser PJ. Inferring microstructural features and the physiological state of tissues from diffusion-weighted images. NMR Biomed 1995;8(7-8):333-344.
    • (1995) NMR Biomed , vol.8 , Issue.7-8 , pp. 333-344
    • Basser, P.J.1
  • 18
    • 0029908076 scopus 로고    scopus 로고
    • Toward a quantitative assessment of diffusion anisotropy
    • Pierpaoli C, Basser PJ. Toward a quantitative assessment of diffusion anisotropy. Magn Reson Med 1996;36(6):893-906.
    • (1996) Magn Reson Med , vol.36 , Issue.6 , pp. 893-906
    • Pierpaoli, C.1    Basser, P.J.2
  • 19
    • 0032417193 scopus 로고    scopus 로고
    • Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging
    • Scollan DF, Holmes A, Winslow R, Forder J. Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging. Am J Physiol 1998;275(6 Pt 2):H2308-H2318.
    • (1998) Am J Physiol , vol.275 , Issue.6 , pp. H2308-H2318
    • Scollan, D.F.1    Holmes, A.2    Winslow, R.3    Forder, J.4
  • 20
    • 0028133448 scopus 로고
    • In vivo measurement of water diffusion in the human heart
    • Edelman RR, Gaa J, Wedeen VJ, et al. In vivo measurement of water diffusion in the human heart. Magn Reson Med 1994;32(3):423-428.
    • (1994) Magn Reson Med , vol.32 , Issue.3 , pp. 423-428
    • Edelman, R.R.1    Gaa, J.2    Wedeen, V.J.3
  • 22
    • 44949111448 scopus 로고    scopus 로고
    • A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI, at 3 Tesla
    • Schmitt M, Potthast A, Sosnovik DE, et al. A 128-channel receive-only cardiac coil for highly accelerated cardiac MRI at 3 Tesla. Magn Reson Med 2008;59(6):1431-1439.
    • (2008) Magn Reson Med , vol.59 , Issue.6 , pp. 1431-1439
    • Schmitt, M.1    Potthast, A.2    Sosnovik, D.E.3
  • 23
    • 84899942889 scopus 로고    scopus 로고
    • Microstructural impact of ischemia and bone marrow-derived cell therapy revealed with diffusion tensor magnetic resonance imaging tractography of the heart in vivo
    • Sosnovik DE, Mekkaoui C, Huang S, et al. Microstructural impact of ischemia and bone marrow-derived cell therapy revealed with diffusion tensor magnetic resonance imaging tractography of the heart in vivo. Circulation 2014;129(17):1731-1741.
    • (2014) Circulation , vol.129 , Issue.17 , pp. 1731-1741
    • Sosnovik, D.E.1    Mekkaoui, C.2    Huang, S.3
  • 24
    • 84930333127 scopus 로고    scopus 로고
    • Second-order motioncompensated spin echo diffusion tensor imaging of the human heart
    • Stoeck CT, von Deuster C, Genet M, Atkinson D, Kozerke S. Second-order motioncompensated spin echo diffusion tensor imaging of the human heart. Magn Reson Med 2016;75(4):1669-1676.
    • (2016) Magn Reson Med , vol.75 , Issue.4 , pp. 1669-1676
    • Stoeck, C.T.1    Von Deuster, C.2    Genet, M.3    Atkinson, D.4    Kozerke, S.5
  • 25
    • 84907954026 scopus 로고    scopus 로고
    • In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: A motion compensated diffusion-prepared balanced steadystate free precession approach
    • Nguyen C, Fan Z, Sharif B, et al. In vivo three-dimensional high resolution cardiac diffusion-weighted MRI: A motion compensated diffusion-prepared balanced steadystate free precession approach. Magn Reson Med 2014;72(5):1257-1267.
    • (2014) Magn Reson Med , vol.72 , Issue.5 , pp. 1257-1267
    • Nguyen, C.1    Fan, Z.2    Sharif, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.