메뉴 건너뛰기




Volumn 2016-October, Issue , 2016, Pages 3031-3034

Meandered conformai antenna for ISM-band ingestible capsule communication systems

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL; COMPUTER NETWORK; COMPUTER SIMULATION; HUMAN; PIG; RED MEAT; THEORETICAL MODEL; WIRELESS COMMUNICATION;

EID: 85009114606     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2016.7591368     Document Type: Conference Paper
Times cited : (17)

References (19)
  • 1
    • 84862969409 scopus 로고    scopus 로고
    • Swallowable wireless capsule endoscopy: Progress and technical challenges
    • G. Pan and L. Wang, "Swallowable Wireless Capsule Endoscopy: Progress and Technical Challenges," Gastroenterol. Res. Pract., vol. 2012, pp. 841691, 2012
    • (2012) Gastroenterol. Res. Pract. , vol.2012 , pp. 841691
    • Pan, G.1    Wang, L.2
  • 3
    • 34547685609 scopus 로고    scopus 로고
    • New frontiers in capsule endoscopy
    • Jun.
    • Z. Fireman and Y. Kopelman, "New frontiers in capsule endoscopy," J Gastroenterol Hepatol., vol. 22, no. 8, pp. 1174-1177, Jun. 2007
    • (2007) J Gastroenterol Hepatol. , vol.22 , Issue.8 , pp. 1174-1177
    • Fireman, Z.1    Kopelman, Y.2
  • 5
    • 84897070665 scopus 로고    scopus 로고
    • Implantable and ingestible medical devices with wireless telemetry functionalities: A review of current status and challenges
    • Jan.
    • A. Kiourti, K.A. Psathas, and K.S. Nikita, "Implantable and ingestible medical devices with wireless telemetry functionalities: a review of current status and challenges," Bioelectromagnetics, vol. 35, no. 1, pp. 1-15, Jan. 2014
    • (2014) Bioelectromagnetics , vol.35 , Issue.1 , pp. 1-15
    • Kiourti, A.1    Psathas, K.A.2    Nikita, K.S.3
  • 6
    • 68049137665 scopus 로고    scopus 로고
    • Effects of dielectric parameters of human body on radiation characteristics of ingestible wireless device at operating frequency of 430 MHz
    • Aug.
    • L. Xu, M.Q-H. Meng, and Y. Chan, "Effects of Dielectric Parameters of Human Body on Radiation Characteristics of Ingestible Wireless Device at Operating Frequency of 430 MHz," IEEE Trans. Biomed. Eng., vol. 56, no. 8, pp. 2083-2094, Aug. 2009
    • (2009) IEEE Trans. Biomed. Eng. , vol.56 , Issue.8 , pp. 2083-2094
    • Xu, L.1    Meng, M.Q.-H.2    Chan, Y.3
  • 7
    • 68949218926 scopus 로고    scopus 로고
    • Radiation characteristics of ingestible wireless devices in human intestine following radio frequency exposure at 430, 800, 1200, and 2400 MHz
    • Aug.
    • L. Xu, M.Q-H. Meng, H. Ren, and Y. Chan, "Radiation Characteristics of Ingestible Wireless Devices in Human Intestine Following Radio Frequency Exposure at 430, 800, 1200, and 2400 MHz," IEEE Trans. Antennas Propag., vol. 57, no. 8, pp. 2418-2428, Aug. 2009
    • (2009) IEEE Trans. Antennas Propag. , vol.57 , Issue.8 , pp. 2418-2428
    • Xu, L.1    Meng, M.Q.-H.2    Ren, H.3    Chan, Y.4
  • 8
    • 33750916342 scopus 로고    scopus 로고
    • Small spiral antenna for wideband capsule endoscope system
    • Nov.
    • S.I. Kwak, K. Chang, and Y.J. Yoon, "Small spiral antenna for wideband capsule endoscope system," Electronics Letters, vol. 42, no. 23, pp. 1328-1329, Nov. 2006
    • (2006) Electronics Letters , vol.42 , Issue.23 , pp. 1328-1329
    • Kwak, S.I.1    Chang, K.2    Yoon, Y.J.3
  • 9
    • 79956355269 scopus 로고    scopus 로고
    • A wideband spiral antenna for ingestible capsule endoscope systems: Experimental results in a human phantom and a pig
    • Jun.
    • S.H. Lee, J. Lee, Y.J. Yoon, S. Park, C. Cheon, K. Kim, and S. Nam, "A Wideband Spiral Antenna for Ingestible Capsule Endoscope Systems: Experimental Results in a Human Phantom and a Pig," IEEE Trans. Biomed. Eng. , vol. 58, no. 6, pp. 1734-1741, Jun. 2011
    • (2011) IEEE Trans. Biomed. Eng. , vol.58 , Issue.6 , pp. 1734-1741
    • Lee, S.H.1    Lee, J.2    Yoon, Y.J.3    Park, S.4    Cheon, C.5    Kim, K.6    Nam, S.7
  • 11
    • 84884782572 scopus 로고    scopus 로고
    • A novel conformal antenna for ingestible capsule endoscopy in the med-radio band
    • 1215 Aug. Stockholm, Sweden
    • K.A. Psathas, A. Kiourti, K.S. Nikita, "A novel conformal antenna for ingestible capsule endoscopy in the med-radio band," Electromagnetic Research Symposium Proceedings, Stockholm, Sweden, pp. 1899-902, 1215 Aug. 2013
    • (2013) Electromagnetic Research Symposium Proceedings , pp. 1899-1902
    • Psathas, K.A.1    Kiourti, A.2    Nikita, K.S.3
  • 12
    • 84863054899 scopus 로고    scopus 로고
    • A compact omnidirectional self-packaged patch antenna with complementary split-ring resonator loading for wireless endoscope applications
    • X. Cheng, D.E. Senior, C. Kim, and Y.-K. Yoon, "A Compact Omnidirectional Self-Packaged Patch Antenna With Complementary Split-Ring Resonator Loading for Wireless Endoscope Applications," IEEE Antennas Wireless Propag. Lett. , vol. 10, no., pp.1532-1535, 2011
    • (2011) IEEE Antennas Wireless Propag. Lett. , vol.10 , pp. 1532-1535
    • Cheng, X.1    Senior, D.E.2    Kim, C.3    Yoon, Y.-K.4
  • 14
    • 65549138854 scopus 로고    scopus 로고
    • Conformal ingestible capsule antenna: A novel chandelier meandered design
    • Apr.
    • P.M. Izdebski, H. Rajagopalan, Y. Rahmat-Samii, "Conformal Ingestible Capsule Antenna: A Novel Chandelier Meandered Design," IEEE Trans. Antennas Propag., vol. 57, no. 4, pp. 900-909, Apr. 2009
    • (2009) IEEE Trans. Antennas Propag. , vol.57 , Issue.4 , pp. 900-909
    • Izdebski, P.M.1    Rajagopalan, H.2    Rahmat-Samii, Y.3
  • 15
    • 85008061074 scopus 로고    scopus 로고
    • Outer-wall loop antenna for ultrawideband capsule endoscope system
    • Nov.
    • S. Yun; K. Kim, and S. Nam, "Outer-Wall Loop Antenna for Ultrawideband Capsule Endoscope System," IEEE Antennas Wireless Propag. Lett., vol. 9, pp. 1135-1138, Nov. 2010
    • (2010) IEEE Antennas Wireless Propag. Lett. , vol.9 , pp. 1135-1138
    • Yun, S.1    Kim, K.2    Nam, S.3
  • 16
    • 85009139117 scopus 로고    scopus 로고
    • www.cst.com, 2014
    • (2014)
  • 17
    • 79960148488 scopus 로고    scopus 로고
    • Rectenna application of miniaturized implantable antenna design for triple-band biotelemetry communication
    • Jul.
    • F.-J. Huang, C.-M. Lee, C.-L. Chang, L.-K. Chen, T.-C. Yo, and C.-H. Luo, "Rectenna Application of Miniaturized Implantable Antenna Design for Triple-Band Biotelemetry Communication," IEEE Trans. Antennas Propag., vol. 59, no. 7, pp. 2646-2653, Jul. 2011
    • (2011) IEEE Trans. Antennas Propag. , vol.59 , Issue.7 , pp. 2646-2653
    • Huang, F.-J.1    Lee, C.-M.2    Chang, C.-L.3    Chen, L.-K.4    Yo, T.-C.5    Luo, C.-H.6
  • 19
    • 85009094485 scopus 로고    scopus 로고
    • Characterization of path loss and absorption for a wireless radio frequency link between an in-body endoscopy capsule and a receiver outside the body
    • K.L.-L. Roman, G. Vermeeren, A. Thielens, W. Joseph , and L. Martens, "Characterization of path loss and absorption for a wireless radio frequency link between an in-body endoscopy capsule and a receiver outside the body," EURASIP Journal on Wireless Communi-
    • EURASIP Journal on Wireless Communi
    • Roman, K.L.-L.1    Vermeeren, G.2    Thielens, A.3    Joseph, W.4    Martens, L.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.