-
1
-
-
0030033440
-
The rationales of interlocking nailing of the femur, tibia, and humerus: An overview
-
Brumback, R. J. The rationales of interlocking nailing of the femur, tibia, and humerus: an overview. Clinical Orthopedics 1996, 324, 292–320.
-
(1996)
Clinical Orthopedics
, vol.324
, pp. 292-320
-
-
Brumback, R.J.1
-
2
-
-
0036196593
-
Screw pullout strength: A biomechanical comparison of largefragment and small-fragment fixation in the tibial plateau
-
Westmoreland, G. L.; McLaurin, T. M.; Hutton, W. C. Screw pullout strength: a biomechanical comparison of largefragment and small-fragment fixation in the tibial plateau. Orthopedic Trauma 2002, 16, 178–181.
-
(2002)
Orthopedic Trauma
, vol.16
, pp. 178-181
-
-
Westmoreland, G.L.1
McLaurin, T.M.2
Hutton, W.C.3
-
3
-
-
40449087422
-
Enhanced osteoblast functions on anodized titanium with nanotube-like structures
-
Yao, C.; Slamovich, E. B.; Webster, T. J. Enhanced osteoblast functions on anodized titanium with nanotube-like structures. Biomedical Materials Research Part A 2008, 85A(1), 157–166.
-
(2008)
Biomedical Materials Research Part A
, vol.85A
, Issue.1
, pp. 157-166
-
-
Yao, C.1
Slamovich, E.B.2
Webster, T.J.3
-
4
-
-
34247490766
-
Influence of engineered titania nanotubular surfaces on bone cells
-
Popat, K. C.; Leoni, L.; Grimes, C. A.; Desai, T. A. Influence of engineered titania nanotubular surfaces on bone cells. Biomaterials 2007, 28(21), 3188–3197.
-
(2007)
Biomaterials
, vol.28
, Issue.21
, pp. 3188-3197
-
-
Popat, K.C.1
Leoni, L.2
Grimes, C.A.3
Desai, T.A.4
-
5
-
-
75749148812
-
Titanium dioxide nanotubes enhance bone bonding in vivo
-
Bjursten, L. M.; Rasmusson, L.; Oh, S.; Smith, G. C.; Brammer, K. S.; Jin, S. Titanium dioxide nanotubes enhance bone bonding in vivo. Biomedical Materials Research Part A 2010, 92A(3), 1218–1224.
-
(2010)
Biomedical Materials Research Part A
, vol.92A
, Issue.3
, pp. 1218-1224
-
-
Bjursten, L.M.1
Rasmusson, L.2
Oh, S.3
Smith, G.C.4
Brammer, K.S.5
Jin, S.6
-
6
-
-
80755149812
-
Surface engineering of titania for excellent fibroblast 3T3 cellmetal interaction
-
Hazan, R.; Sreekantan, S.; Abdul Khalil, A.; Nordin, I. M. S.; Mat, I. Surface engineering of titania for excellent fibroblast 3T3 cellmetal interaction. Physical Science 2009, 20(1), 35–47.
-
(2009)
Physical Science
, vol.20
, Issue.1
, pp. 35-47
-
-
Hazan, R.1
Sreekantan, S.2
Abdul Khalil, A.3
Nordin, I.M.S.4
Mat, I.5
-
7
-
-
63149176535
-
2 nanotube surfaces: 15 nm – an optimal length scale of surface topography for cell adhesion and differentiation
-
2 nanotube surfaces: 15 nm – an optimal length scale of surface topography for cell adhesion and differentiation. Small 2009, 5(6), 666–671.
-
(2009)
Small
, vol.5
, Issue.6
, pp. 666-671
-
-
Park, J.1
Bauer, S.2
Schlegel, K.A.3
Neukam, F.W.4
von der Mark, K.5
Schmuki, P.6
-
9
-
-
33745600877
-
2 nanotubes
-
2 nanotubes. Biomedical Materials Research Part A 2006, 78A(1), 97–103.
-
(2006)
Biomedical Materials Research Part A
, vol.78A
, Issue.1
, pp. 97-103
-
-
Oh, S.1
Daraio, C.2
Chen, L.-H.3
Pisanic, T.R.4
Fiñones, R.R.5
Jin, S.6
-
10
-
-
70349146591
-
2 nanotube surface
-
2 nanotube surface. Acta Biomaterialia 2009, 5(8), 3215–3223.
-
(2009)
Acta Biomaterialia
, vol.5
, Issue.8
, pp. 3215-3223
-
-
Brammer, K.S.1
Oh, S.2
Cobb, C.J.3
Bjursten, L.M.4
Heyde, H.V.D.5
Jin, S.6
-
11
-
-
60549098069
-
Stem cell fate dictated solely by altered nanotube dimension
-
Oh, S.; Brammer, K. S.; Li, Y. S. J.; Teng, D.; Engler, A. J.; Chien, S.; Jin, S. Stem cell fate dictated solely by altered nanotube dimension. Proceedings of the National Academy of Sciences 2009, 106(7), 2130–2135.
-
(2009)
Proceedings of the National Academy of Sciences
, vol.106
, Issue.7
, pp. 2130-2135
-
-
Oh, S.1
Brammer, K.S.2
Li, Y.S.J.3
Teng, D.4
Engler, A.J.5
Chien, S.6
Jin, S.7
-
13
-
-
77956412784
-
The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models
-
Patel, S.; Shepherd, D.; Hukins, D. The effect of screw insertion angle and thread type on the pullout strength of bone screws in normal and osteoporotic cancellous bone models. Medical Engineering & Physics 2010, 32(8), 822–828.
-
(2010)
Medical Engineering & Physics
, vol.32
, Issue.8
, pp. 822-828
-
-
Patel, S.1
Shepherd, D.2
Hukins, D.3
-
14
-
-
0037384148
-
Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone
-
Giavaresi, G.; Fini, M.; Cigada, A.; Chiesa, R.; Rondelli, G.; Rimondini, L.; Torricelli, P.; Aldini, N.; Giardino, R. Mechanical and histomorphometric evaluations of titanium implants with different surface treatments inserted in sheep cortical bone. Biomaterials 2003, 24(9), 1583–1594.
-
(2003)
Biomaterials
, vol.24
, Issue.9
, pp. 1583-1594
-
-
Giavaresi, G.1
Fini, M.2
Cigada, A.3
Chiesa, R.4
Rondelli, G.5
Rimondini, L.6
Torricelli, P.7
Aldini, N.8
Giardino, R.9
-
16
-
-
70350681109
-
Direct compressive measurements of individual titanium dioxide nanotubes
-
Shokuhfar, T.; Arumugam, G.; Heiden, P.; Yassar, R.; Friedrich, C. Direct compressive measurements of individual titanium dioxide nanotubes. ACS Nano 2009, 3(10), 3098–3102.
-
(2009)
ACS Nano
, vol.3
, Issue.10
, pp. 3098-3102
-
-
Shokuhfar, T.1
Arumugam, G.2
Heiden, P.3
Yassar, R.4
Friedrich, C.5
|