메뉴 건너뛰기




Volumn 7, Issue 3, 2016, Pages 265-269

Heads-Up Macular Surgery with a 27-Gauge Microincision Vitrectomy System and Minimal Illumination

Author keywords

27 Gauge vitrectomy; Epiretinal membrane; Heads up surgery; Macular hole; Phototoxicity

Indexed keywords

ARTICLE; CASE STUDY; CLINICAL ARTICLE; FOLLOW UP; HUMAN; INTERVENTION STUDY; INTRAOCULAR ILLUMINATOR; MICROSCOPE; OPHTHALMOLOGICAL SURGICAL EQUIPMENT; PHOTOTOXICITY; POSTOPERATIVE COMPLICATION; RETINA; RETINA CELL; RETINA MACULOPATHY; RETROSPECTIVE STUDY; SURGICAL TECHNIQUE; VISUAL ACUITY; VITRECTOMY;

EID: 85000956248     PISSN: None     EISSN: 16632699     Source Type: Journal    
DOI: 10.1159/000452993     Document Type: Article
Times cited : (37)

References (5)
  • 1
    • 0019831222 scopus 로고
    • Vitreous surgery for macular pucker
    • Michels RG: Vitreous surgery for macular pucker. Am J Ophthalmol 1981;92: 628-639.
    • (1981) Am J Ophthalmol , vol.92 , pp. 628-639
    • Michels, R.G.1
  • 2
    • 33845485896 scopus 로고    scopus 로고
    • Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery
    • Oshima Y, Awh CC, Tano Y: Self-retaining 27-gauge transconjunctival chandelier endoillumination for panoramic viewing during vitreous surgery. Am J Ophthalmol 2007;143: 166-167.
    • (2007) Am J Ophthalmol , vol.143 , pp. 166-167
    • Oshima, Y.1    Awh, C.C.2    Tano, Y.3
  • 3
    • 84963800246 scopus 로고    scopus 로고
    • Comparative study of 27-gauge vs 25-gauge vitrectomy for epiretinal membrane
    • Mitsui K, Kogo J, Takeda H, et al. Comparative study of 27-gauge vs 25-gauge vitrectomy for epiretinal membrane. Eye (Lond) 2016;30: 538-544.
    • (2016) Eye (Lond) , vol.30 , pp. 538-544
    • Mitsui, K.1    Kogo, J.2    Takeda, H.3
  • 4
    • 34250719381 scopus 로고    scopus 로고
    • Evaluation of the safety of xenon/bandpass light in vitrectomy using the A2E-laden RPE model
    • Yanagi Y, Iriyama A, Jang WD, Kadonosono K: Evaluation of the safety of xenon/bandpass light in vitrectomy using the A2E-laden RPE model. Graefes Arch Clin Exp Ophthalmol 2007;245: 677-681.
    • (2007) Graefes Arch Clin Exp Ophthalmol , vol.245 , pp. 677-681
    • Yanagi, Y.1    Iriyama, A.2    Jang, W.D.3    Kadonosono, K.4
  • 5
    • 84952884767 scopus 로고    scopus 로고
    • Heads-up surgery for vitreoretinal procedures: An experimental and clinical study
    • Eckardt C, Paulo EB: Heads-up surgery for vitreoretinal procedures: An experimental and clinical study. Retina 2016; 36: 137-147.
    • (2016) Retina , vol.36 , pp. 137-147
    • Eckardt, C.1    Paulo, E.B.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.