-
1
-
-
0033643551
-
Pitfalls in the determination of common analytes in the critically ill
-
Delanghe J. Pitfalls in the determination of common analytes in the critically ill. Acta Clin Belg 2000;55:4-8.
-
(2000)
Acta Clin Belg
, vol.55
, pp. 4-8
-
-
Delanghe, J.1
-
2
-
-
33644831902
-
Influence of hemolysis on routine clinical chemistry testing
-
Lippi G, Salvagno GL, Montagnana M, Brocco G, Guidi GC. Influence of hemolysis on routine clinical chemistry testing. Clin Chem Lab Med 2006;44:311-6.
-
(2006)
Clin Chem Lab Med
, vol.44
, pp. 311-316
-
-
Lippi, G.1
Salvagno, G.L.2
Montagnana, M.3
Brocco, G.4
Guidi, G.C.5
-
3
-
-
33747826626
-
Blood samples with hemolysis: Clinical consequences?
-
Nybo M, Nielsen HR, Hansen AB. Blood samples with hemolysis: clinical consequences?. Ugeskr Laeger 2006;168:2653-5.
-
(2006)
Ugeskr Laeger
, vol.168
, pp. 2653-2655
-
-
Nybo, M.1
Nielsen, H.R.2
Hansen, A.B.3
-
4
-
-
0035146165
-
Frequent overcrowding in U.S. emergency departments
-
Derlet R, Richards J, Kravitz R. Frequent overcrowding in U.S. emergency departments. Acad Emerg Med 2001;8:151-5.
-
(2001)
Acad Emerg Med
, vol.8
, pp. 151-155
-
-
Derlet, R.1
Richards, J.2
Kravitz, R.3
-
5
-
-
0026720420
-
Effect of in vitro hemolysis on 25 common biochemical tests
-
Yucel D, Dalva K. Effect of in vitro hemolysis on 25 common biochemical tests. Clin Chem 1992;38:575-7.
-
(1992)
Clin Chem
, vol.38
, pp. 575-577
-
-
Yucel, D.1
Dalva, K.2
-
6
-
-
0032160128
-
Scaling of hemolysis in needles and catheters
-
Sharp MK, Mohammad SF. Scaling of hemolysis in needles and catheters. Ann Biomed Eng 1998;26:788-97.
-
(1998)
Ann Biomed Eng
, vol.26
, pp. 788-797
-
-
Sharp, M.K.1
Mohammad, S.F.2
-
7
-
-
24044454046
-
Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department
-
Dugan L, Leech L, Speroni KG, Corriher J. Factors affecting hemolysis rates in blood samples drawn from newly placed IV sites in the emergency department. J Emerg Nurs 2005;31:338-45.
-
(2005)
J Emerg Nurs
, vol.31
, pp. 338-345
-
-
Dugan, L.1
Leech, L.2
Speroni, K.G.3
Corriher, J.4
-
8
-
-
18744426448
-
A prolonged time interval between blood sample collection and centrifugation causes an increase in serum carbohydrate-deficient transferrin
-
Arndt T, Kropf J. A prolonged time interval between blood sample collection and centrifugation causes an increase in serum carbohydrate-deficient transferrin. Med Sci Monit 2002;8:BR61-4.
-
(2002)
Med Sci Monit
, vol.8
-
-
Arndt, T.1
Kropf, J.2
-
9
-
-
0036893555
-
Stability studies of twenty-four analytes in human plasma and serum
-
Boyanton BL Jr, Blick KE. Stability studies of twenty-four analytes in human plasma and serum. Clin Chem 2002;48:2242-7.
-
(2002)
Clin Chem
, vol.48
, pp. 2242-2247
-
-
Boyanton Jr, B.L.1
Blick, K.E.2
-
10
-
-
10344259079
-
Blood samples drawn from IV catheters have less hemolysis when 5-mL (vs 10-mL) collection tubes are used
-
Cox SR, Dages JH, Jarjoura D, Hazelett S. Blood samples drawn from IV catheters have less hemolysis when 5-mL (vs 10-mL) collection tubes are used. J Emerg Nurs 2004;30:529-33.
-
(2004)
J Emerg Nurs
, vol.30
, pp. 529-533
-
-
Cox, S.R.1
Dages, J.H.2
Jarjoura, D.3
Hazelett, S.4
-
11
-
-
33750445931
-
Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques
-
Dwyer DG, Fry M, Somerville A, Holdgate A. Randomized, single blinded control trial comparing haemolysis rate between two cannula aspiration techniques. Emerg Med Australas 2006;18:484-8.
-
(2006)
Emerg Med Australas
, vol.18
, pp. 484-488
-
-
Dwyer, D.G.1
Fry, M.2
Somerville, A.3
Holdgate, A.4
-
12
-
-
85173397117
-
-
Grant MS. The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples. J Emerg Nurs 2003;29: 116-21.
-
Grant MS. The effect of blood drawing techniques and equipment on the hemolysis of ED laboratory blood samples. J Emerg Nurs 2003;29: 116-21.
-
-
-
-
13
-
-
0030342298
-
A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples
-
Kennedy C, Angermuller S, King R, Noviello S, Walker J, Warden J, et al. A comparison of hemolysis rates using intravenous catheters versus venipuncture tubes for obtaining blood samples. J Emerg Nurs 1996;22:566-9.
-
(1996)
J Emerg Nurs
, vol.22
, pp. 566-569
-
-
Kennedy, C.1
Angermuller, S.2
King, R.3
Noviello, S.4
Walker, J.5
Warden, J.6
-
14
-
-
0032200902
-
Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters
-
Fincher RK, Strong JS, Jackson JL. Accuracy of measurements of hemoglobin and potassium in blood samples from peripheral catheters. Am J Crit Care 1998;7:439-43.
-
(1998)
Am J Crit Care
, vol.7
, pp. 439-443
-
-
Fincher, R.K.1
Strong, J.S.2
Jackson, J.L.3
-
15
-
-
0029334349
-
Are Irish general practitioners minimising infection risk from sharps?
-
Caird A, Wann C. Are Irish general practitioners minimising infection risk from sharps? Ir Med J 1995;88:132-4.
-
(1995)
Ir Med J
, vol.88
, pp. 132-134
-
-
Caird, A.1
Wann, C.2
-
16
-
-
34447277111
-
Studies on preanalytical phase errors in clinical chemistry in the Japanese clinical laboratory - now and the future (Japanese)
-
Tomita A, Kizawa S. Studies on preanalytical phase errors in clinical chemistry in the Japanese clinical laboratory - now and the future (Japanese). Rinsho Byori 2007;55:473-8.
-
(2007)
Rinsho Byori
, vol.55
, pp. 473-478
-
-
Tomita, A.1
Kizawa, S.2
|