메뉴 건너뛰기




Volumn 27, Issue 12, 2016, Pages 1403-1410

Performance of an Implantable Cardiac Monitor to Detect Atrial Fibrillation: Results of the DETECT AF Study

(15)  NÖLker, Georg a   Mayer, Julia b   Boldt, Leif Hendrik c   Seidl, Karlheinz d   Van Driel, Vincent e   Massa, Thomas f   Kollum, Marc g   Brachmann, Johannes h   Deneke, Thomas i   Hindricks, Gerhard j   Jung, Werner k   Brunner, Kyle J l   Kraus, Stacia m   HÜmmer, Alexander n   Lewalter, Thorsten o  

f SANOFI   (France)

Author keywords

atrial fibrillation; diagnosis; implantable cardiac monitor; monitoring

Indexed keywords

AGED; ARTICLE; ATRIAL FIBRILLATION; DIAGNOSTIC ACCURACY; DIAGNOSTIC TEST ACCURACY STUDY; FEMALE; GERMANY; HOLTER MONITOR; HOLTER MONITORING; HUMAN; IMPLANTABLE CARDIAC MONITOR; MAJOR CLINICAL STUDY; MALE; MULTICENTER STUDY; NETHERLANDS; PATIENT ASSESSMENT; PREDICTIVE VALUE; PRIORITY JOURNAL; PROSPECTIVE STUDY; SENSITIVITY AND SPECIFICITY; ACTION POTENTIAL; AMBULATORY ELECTROCARDIOGRAPHY; CLINICAL TRIAL; COMPARATIVE STUDY; DEVICES; EQUIPMENT DESIGN; HEART MUSCLE CONDUCTION SYSTEM; HEART RATE; MATERIALS TESTING; MIDDLE AGED; PATHOPHYSIOLOGY; REPRODUCIBILITY; SIGNAL PROCESSING; TRANSDUCER;

EID: 84991056838     PISSN: 10453873     EISSN: 15408167     Source Type: Journal    
DOI: 10.1111/jce.13089     Document Type: Article
Times cited : (51)

References (17)
  • 1
    • 0030995765 scopus 로고    scopus 로고
    • Relationship between prothrombin activation fragment f1.2 and international normalized ratio in patients with atrial fibrillation. Stroke prevention in atrial fibrillation investigators
    • Feinberg WM, Cornell ES, Nightingale SD, Pearce LA, Tracy RP, Hart RG, Bovill EG: Relationship between prothrombin activation fragment f1.2 and international normalized ratio in patients with atrial fibrillation. Stroke prevention in atrial fibrillation investigators. Stroke 1997;28:1101-1106.
    • (1997) Stroke , vol.28 , pp. 1101-1106
    • Feinberg, W.M.1    Cornell, E.S.2    Nightingale, S.D.3    Pearce, L.A.4    Tracy, R.P.5    Hart, R.G.6    Bovill, E.G.7
  • 4
    • 0037382858 scopus 로고    scopus 로고
    • MOST Investigators: Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: Report of the atrial diagnostics ancillary study of the mode selection trial (most)
    • Glotzer TV, Hellkamp AS, Zimmerman J, Sweeney MO, Yee R, Marinchak R, Cook J, Paraschos A, Love J, Radoslovich G, Lee KL, Lamas GA; MOST Investigators: Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke: Report of the atrial diagnostics ancillary study of the mode selection trial (most). Circulation 2003;107:1614-1619.
    • (2003) Circulation , vol.107 , pp. 1614-1619
    • Glotzer, T.V.1    Hellkamp, A.S.2    Zimmerman, J.3    Sweeney, M.O.4    Yee, R.5    Marinchak, R.6    Cook, J.7    Paraschos, A.8    Love, J.9    Radoslovich, G.10    Lee, K.L.11    Lamas, G.A.12
  • 5
    • 33750377141 scopus 로고    scopus 로고
    • Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording
    • de Voogt WG, van Hemel NM, van de Bos AA, Koistinen J, Fast JH: Verification of pacemaker automatic mode switching for the detection of atrial fibrillation and atrial tachycardia with Holter recording. Europace 2006;8:950-961.
    • (2006) Europace , vol.8 , pp. 950-961
    • de Voogt, W.G.1    van Hemel, N.M.2    van de Bos, A.A.3    Koistinen, J.4    Fast, J.H.5
  • 8
    • 0141836078 scopus 로고    scopus 로고
    • Use of the implantable loop recorder in evaluation of patients with unexplained syncope
    • Krahn AD, Klein GJ, Skanes AC, Yee R: Use of the implantable loop recorder in evaluation of patients with unexplained syncope. J Cardiovasc Electrophysiol 2003;14:S70-73.
    • (2003) J Cardiovasc Electrophysiol , vol.14 , pp. S70-73
    • Krahn, A.D.1    Klein, G.J.2    Skanes, A.C.3    Yee, R.4
  • 11
    • 79953772902 scopus 로고    scopus 로고
    • Performance of an implantable automatic atrial fibrillation detection device: Impact of software adjustments and relevance of manual episode analysis
    • Eitel C, Husser D, Hindricks G, Fruhauf M, Hilbert S, Arya A, Gaspar T, Wetzel U, Bollmann A, Piorkowski C: Performance of an implantable automatic atrial fibrillation detection device: Impact of software adjustments and relevance of manual episode analysis. Europace 2011;13:480-485.
    • (2011) Europace , vol.13 , pp. 480-485
    • Eitel, C.1    Husser, D.2    Hindricks, G.3    Fruhauf, M.4    Hilbert, S.5    Arya, A.6    Gaspar, T.7    Wetzel, U.8    Bollmann, A.9    Piorkowski, C.10
  • 12
    • 77951896083 scopus 로고    scopus 로고
    • XPECT Trial Investigators: Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation results of the XPECT trial
    • Hindricks G, Pokushalov E, Urban L, Taborsky M, Kuck K-H, Lebedev D, Rieger G, Pürerfellner H; XPECT Trial Investigators: Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation results of the XPECT trial. Circ Arrhyth Electrophysiol 2010;3:141-147.
    • (2010) Circ Arrhyth Electrophysiol , vol.3 , pp. 141-147
    • Hindricks, G.1    Pokushalov, E.2    Urban, L.3    Taborsky, M.4    Kuck, K.-H.5    Lebedev, D.6    Rieger, G.7    Pürerfellner, H.8
  • 13
    • 85007550005 scopus 로고    scopus 로고
    • Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms
    • Association for the Advancement of Medical Instrumentation, Arlington
    • ANSi/AAMI. Testing and reporting performance results of cardiac rhythm and ST segment measurement algorithms. VF and AF comparisons; Association for the Advancement of Medical Instrumentation, Arlington 2013, p 16.
    • (2013) VF and AF comparisons , pp. 16
  • 14
    • 84906700706 scopus 로고    scopus 로고
    • P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors
    • Pürerfellner H, Pokushalov E, Sarkar S, Koehler J, Zhou R, Urban L, Hindricks G: P-wave evidence as a method for improving algorithm to detect atrial fibrillation in insertable cardiac monitors. Heart Rhythm 2014;11:1575-1583.
    • (2014) Heart Rhythm , vol.11 , pp. 1575-1583
    • Pürerfellner, H.1    Pokushalov, E.2    Sarkar, S.3    Koehler, J.4    Zhou, R.5    Urban, L.6    Hindricks, G.7
  • 15
    • 84983593703 scopus 로고    scopus 로고
    • Are implantable cardiac monitors the ‘gold standard’ for atrial fibrillation detection? A prospective randomized trial comparing atrial fibrillation monitoring using implantable cardiac monitors and DDDRP permanent pacemakers in post atrial fibrillation ablation patients
    • Podd SJ, Sugihara C, Furniss SS, Sulke N: Are implantable cardiac monitors the ‘gold standard’ for atrial fibrillation detection? A prospective randomized trial comparing atrial fibrillation monitoring using implantable cardiac monitors and DDDRP permanent pacemakers in post atrial fibrillation ablation patients. Europace 2016;18:1000–1005.
    • (2016) Europace , vol.18 , pp. 1000-1005
    • Podd, S.J.1    Sugihara, C.2    Furniss, S.S.3    Sulke, N.4
  • 16
    • 34247143753 scopus 로고    scopus 로고
    • Clinical implications of various follow up strategies after catheter ablation of atrial fibrillation
    • Arya A, Piorkowski C, Sommer P, Kottkamp H, Hindricks G: Clinical implications of various follow up strategies after catheter ablation of atrial fibrillation. Pacing Clin Electrophysiol 2007;30:458-462.
    • (2007) Pacing Clin Electrophysiol , vol.30 , pp. 458-462
    • Arya, A.1    Piorkowski, C.2    Sommer, P.3    Kottkamp, H.4    Hindricks, G.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.